As a flow measurement instrument widely used by industrial users, the split electromagnetic flowmeter is popular with users because of its many advantages such as not involving the temperature, pressure, density and viscosity of the fluid in the measurement. However, the installation and commissioning of the split electromagnetic flowmeter is more complicated than other flowmeters, and the requirements are more stringent. The transmitter and converter must be used in conjunction, and two different types of instruments cannot be used between the two. When installing the transmitter, from the selection of the installation site to the specific installation and commissioning, it must be operated in accordance with the product installation and use instructions. Therefore, during use, special attention should be paid to the impact of adverse factors in the external environment on the measurement status of the split electromagnetic flowmeter. The engineers of the technical department of Runzhong Instrument Technology Co., Ltd. have summarized the following three precautions for everyone, hoping to attract the attention of all users and friends:
First, the power supply problem. Since the split electromagnetic flowmeter requires an external power supply, it is inconvenient to install it outdoors, and it also limits the use of the split electromagnetic flowmeter in suburban pipe networks. In addition, the split electromagnetic flowmeter does not have its own power supply. Once the power is cut off, the flowmeter data used as the settlement water meter will be missing. This will raise new problems for the measurement and calculation of the missing water volume during the power outage period. Generally, water supply companies and users discuss and deal with each case individually, which increases a lot of workload. If the split electromagnetic flowmeter can have its own power supply, this problem can be fundamentally solved, and it will also promote its promotion and application in settlement water meters. Now it can be powered by lithium batteries, which solves this problem.
The second point is the lightning protection problem. Whether it is a split electromagnetic flowmeter for settlement water meters or regional metering , in relatively open suburbs, especially in Guangdong where thunderstorms cover a large area, the lightning protection of the split electromagnetic flowmeter is a more severe test. After strictly doing grounding and power protection, the probability of being struck by lightning for split electromagnetic flowmeters installed in open areas is still very high. Therefore, the simplest and most effective way is to improve the lightning protection performance of the flowmeter itself. If it cannot be fundamentally solved, its internal circuit should be separated and protected, so that even if it is damaged by lightning, the replacement cost can be reduced. The
third point is the signal transmission problem. The split electromagnetic flowmeter used in the regional pipe network can provide certain decision-making information for urban water supply scheduling, so we hope that the electromagnetic flow signal used for user settlement or regional pipe network is real-time and continuous. The current split electromagnetic flowmeter requires water supply enterprises to develop or select other data transmission systems to achieve real-time monitoring of data. This not only increases cost investment, but also increases the difficulty of operation and management. If the split electromagnetic flowmeter can complete the automatic conversion and wireless transmission of signals in the instrument itself, reducing the compatibility or mutual conversion of data collection, it will provide convenience for the use of enterprises and will also add greater advantages to the promotion and application of split electromagnetic flowmeters.
In general, the split electromagnetic flowmeter has high measurement accuracy, high sensitivity and good stability. The metering application of water supply is becoming more and more extensive, especially in factories, communities and other places with large calibers and good installation environments. The installation and use technology of split electromagnetic flowmeters is already quite mature.
Reference address:Three problems that split electromagnetic flowmeters may encounter during use
First, the power supply problem. Since the split electromagnetic flowmeter requires an external power supply, it is inconvenient to install it outdoors, and it also limits the use of the split electromagnetic flowmeter in suburban pipe networks. In addition, the split electromagnetic flowmeter does not have its own power supply. Once the power is cut off, the flowmeter data used as the settlement water meter will be missing. This will raise new problems for the measurement and calculation of the missing water volume during the power outage period. Generally, water supply companies and users discuss and deal with each case individually, which increases a lot of workload. If the split electromagnetic flowmeter can have its own power supply, this problem can be fundamentally solved, and it will also promote its promotion and application in settlement water meters. Now it can be powered by lithium batteries, which solves this problem.
The second point is the lightning protection problem. Whether it is a split electromagnetic flowmeter for settlement water meters or regional metering , in relatively open suburbs, especially in Guangdong where thunderstorms cover a large area, the lightning protection of the split electromagnetic flowmeter is a more severe test. After strictly doing grounding and power protection, the probability of being struck by lightning for split electromagnetic flowmeters installed in open areas is still very high. Therefore, the simplest and most effective way is to improve the lightning protection performance of the flowmeter itself. If it cannot be fundamentally solved, its internal circuit should be separated and protected, so that even if it is damaged by lightning, the replacement cost can be reduced. The
third point is the signal transmission problem. The split electromagnetic flowmeter used in the regional pipe network can provide certain decision-making information for urban water supply scheduling, so we hope that the electromagnetic flow signal used for user settlement or regional pipe network is real-time and continuous. The current split electromagnetic flowmeter requires water supply enterprises to develop or select other data transmission systems to achieve real-time monitoring of data. This not only increases cost investment, but also increases the difficulty of operation and management. If the split electromagnetic flowmeter can complete the automatic conversion and wireless transmission of signals in the instrument itself, reducing the compatibility or mutual conversion of data collection, it will provide convenience for the use of enterprises and will also add greater advantages to the promotion and application of split electromagnetic flowmeters.
In general, the split electromagnetic flowmeter has high measurement accuracy, high sensitivity and good stability. The metering application of water supply is becoming more and more extensive, especially in factories, communities and other places with large calibers and good installation environments. The installation and use technology of split electromagnetic flowmeters is already quite mature.
Previous article:What are the key points to be aware of when installing a magnetic flap level gauge on the outer extension pipe of a tank?
Next article:Reasons for demagnetization of remote magnetic flap level gauge and related troubleshooting methods
Latest Test Measurement Articles
- Keysight Technologies Helps Samsung Electronics Successfully Validate FiRa® 2.0 Safe Distance Measurement Test Case
- From probes to power supplies, Tektronix is leading the way in comprehensive innovation in power electronics testing
- Seizing the Opportunities in the Chinese Application Market: NI's Challenges and Answers
- Tektronix Launches Breakthrough Power Measurement Tools to Accelerate Innovation as Global Electrification Accelerates
- Not all oscilloscopes are created equal: Why ADCs and low noise floor matter
- Enable TekHSI high-speed interface function to accelerate the remote transmission of waveform data
- How to measure the quality of soft start thyristor
- How to use a multimeter to judge whether a soft starter is good or bad
- What are the advantages and disadvantages of non-contact temperature sensors?
MoreSelected Circuit Diagrams
MorePopular Articles
- Innolux's intelligent steer-by-wire solution makes cars smarter and safer
- 8051 MCU - Parity Check
- How to efficiently balance the sensitivity of tactile sensing interfaces
- What should I do if the servo motor shakes? What causes the servo motor to shake quickly?
- 【Brushless Motor】Analysis of three-phase BLDC motor and sharing of two popular development boards
- Midea Industrial Technology's subsidiaries Clou Electronics and Hekang New Energy jointly appeared at the Munich Battery Energy Storage Exhibition and Solar Energy Exhibition
- Guoxin Sichen | Application of ferroelectric memory PB85RS2MC in power battery management, with a capacity of 2M
- Analysis of common faults of frequency converter
- In a head-on competition with Qualcomm, what kind of cockpit products has Intel come up with?
- Dalian Rongke's all-vanadium liquid flow battery energy storage equipment industrialization project has entered the sprint stage before production
MoreDaily News
- Allegro MicroSystems Introduces Advanced Magnetic and Inductive Position Sensing Solutions at Electronica 2024
- Car key in the left hand, liveness detection radar in the right hand, UWB is imperative for cars!
- After a decade of rapid development, domestic CIS has entered the market
- Aegis Dagger Battery + Thor EM-i Super Hybrid, Geely New Energy has thrown out two "king bombs"
- A brief discussion on functional safety - fault, error, and failure
- In the smart car 2.0 cycle, these core industry chains are facing major opportunities!
- The United States and Japan are developing new batteries. CATL faces challenges? How should China's new energy battery industry respond?
- Murata launches high-precision 6-axis inertial sensor for automobiles
- Ford patents pre-charge alarm to help save costs and respond to emergencies
- New real-time microcontroller system from Texas Instruments enables smarter processing in automotive and industrial applications
Guess you like
- How to read and decode the PPM signal of the RC remote control
- 【TouchGFX Design】graph waveform drawing
- C5000 compiles SUBC instruction to implement division
- [Project source code] Verilog language routine "Wang Jinming: "Verilog HDL Programming Tutorial""
- Recommend a micropython development software thonny
- Understanding design engineers from a system perspective
- [SC8905 EVM Evaluation] +Discharge Output Voltage Regulation
- Recruiting energy storage hardware engineers
- Please analyze the diode in this circuit.
- National Chip 1 at TaoTaoMu Exhibition: Qinheng Beauty Chapter "Bluetooth 5.1 Chip & RISC-V Series MCU"