First, create a new VI project
Next, drag and drop a display panel on the front panel.
Finally, let's deal with the program structure. We hope that the program can be executed infinitely until we ask it to stop. Right-click on a blank area of the back panel (that is, the block diagram panel), select "While Loop" in "Structure", and select Create Input Control for the end condition of the loop. This is all done. The first program will have some flaws, and we will improve it later!
Keywords:LabVIEW
Reference address:LabVIEW Learning Notes - First Program: Waveform Display
Then, press CTRL+E to switch to the program panel to edit the program block diagram. Right-click a blank area in the program panel and select "Basic Function Generator" under "Signal Generation" under the "Signal Processing" module.
”
Right-click the "Signal Type", "Frequency", "Amplitude", and "Phase" ports on the "Basic Function Generator" and select Create Input Control. Finally, connect its "Signal Output" port to the input of the waveform graph.
Finally, let's deal with the program structure. We hope that the program can be executed infinitely until we ask it to stop. Right-click on a blank area of the back panel (that is, the block diagram panel), select "While Loop" in "Structure", and select Create Input Control for the end condition of the loop. This is all done. The first program will have some flaws, and we will improve it later!
Previous article:LabVIEW Learning Notes - Second Program: Sum of Squares of Multiple Integers
Next article:LabVIEW Learning Notes - Related Concepts
Recommended ReadingLatest update time:2024-11-16 14:51
element14 launches sales of NI LabVIEW+ suite to accelerate test product launch
The software packages provided by NI are economical and time-saving, not only helping developers save time, but also providing new opportunities for makers Shanghai, China, February 29, 2024 - element14, a global distributor of electronic components products and solutions owned by Avnet, announced the ready availabi
[Test Measurement]
Causes and solutions for the problem of file not found when compiling LabVIEW
During the program compilation process, the file cannot be found, and the file is found in another location during the compilation process, requiring the programmer to save the file.
1. The first thing that comes to mind is whether the file has been replaced, so the Database tool package is reinstalled (because the
[Test Measurement]
Labview VI initial continuous running problem while loop
There are "Run" and "Link Run" on the front panel. Some programs need to run continuously. How can we achieve the effect of link run in point run? You can add a while loop, drag the original program into the loop, and set the timing time to control the loop frequency.
[Test Measurement]
Teach you how to use OPC in LabVIEW
NI LabVIEW software can communicate with programmable logic controllers (PLCs) in a variety of ways. OLE for Process Control (OPC) defines a standard for real-time object data communication between control devices and human-machine interfaces (HMIs). OPC servers are available for nearly all PLCs and programmable aut
[Test Measurement]
Introduction to LabView Developing Embedded Applications
Regardless of the design language used, poor programming techniques can negatively impact an application's performance, especially for an embedded application. While efficient programming techniques are important for most applications, the resource-starved environments in which embedded applications operate require sp
[Test Measurement]
Design of Network Virtual Laboratory Based on LabVIEW
0 Introduction
With the continuous expansion of enrollment, the experimental equipment of ordinary colleges and universities in China is often outdated and cannot be updated in time, thus failing to keep up with the rapid development of education. At present, higher engineering colleges still use traditiona
[Microcontroller]
Remote control of the LEGO NXT robotic car using the LabVIEW front panel
The software that comes with the LEGO NXT kit is NXT-G software, which is based on the National Instruments LabVIEW software. The NXT-G software interface is simple and easy to understand, but to develop programs with complex functions, a higher-level development platform is required, such as NI's LabVIEW or Microsof
[Test Measurement]
Applying wireless data acquisition methods to bridge collapse testing
Challenge
: Find a way to quickly and safely measure the weight of road fill that would collapse a bridge to the breaking point when the road fill is lifted by a crane boom.
Solution
: By attaching a load cell sensor to the load-bearing cable of the vehicle-mounted crane hanging bucket and connectin
[Test Measurement]
- Popular Resources
- Popular amplifiers
- 100 Examples of Microcontroller C Language Applications (with CD-ROM, 3rd Edition) (Wang Huiliang, Wang Dongfeng, Dong Guanqiang)
- Arduino Nano collects temperature and humidity data through LabVIEW and DHT11
- Modern Testing Technology and System Integration (Liu Junhua)
- Computer Control System Analysis, Design and Implementation Technology (Edited by Li Dongsheng, Zhu Wenxing, Gao Rui)
Recommended Content
Latest Test Measurement Articles
- Keysight Technologies Helps Samsung Electronics Successfully Validate FiRa® 2.0 Safe Distance Measurement Test Case
- From probes to power supplies, Tektronix is leading the way in comprehensive innovation in power electronics testing
- Seizing the Opportunities in the Chinese Application Market: NI's Challenges and Answers
- Tektronix Launches Breakthrough Power Measurement Tools to Accelerate Innovation as Global Electrification Accelerates
- Not all oscilloscopes are created equal: Why ADCs and low noise floor matter
- Enable TekHSI high-speed interface function to accelerate the remote transmission of waveform data
- How to measure the quality of soft start thyristor
- How to use a multimeter to judge whether a soft starter is good or bad
- What are the advantages and disadvantages of non-contact temperature sensors?
MoreSelected Circuit Diagrams
MorePopular Articles
- Innolux's intelligent steer-by-wire solution makes cars smarter and safer
- 8051 MCU - Parity Check
- How to efficiently balance the sensitivity of tactile sensing interfaces
- What should I do if the servo motor shakes? What causes the servo motor to shake quickly?
- 【Brushless Motor】Analysis of three-phase BLDC motor and sharing of two popular development boards
- Midea Industrial Technology's subsidiaries Clou Electronics and Hekang New Energy jointly appeared at the Munich Battery Energy Storage Exhibition and Solar Energy Exhibition
- Guoxin Sichen | Application of ferroelectric memory PB85RS2MC in power battery management, with a capacity of 2M
- Analysis of common faults of frequency converter
- In a head-on competition with Qualcomm, what kind of cockpit products has Intel come up with?
- Dalian Rongke's all-vanadium liquid flow battery energy storage equipment industrialization project has entered the sprint stage before production
MoreDaily News
- Allegro MicroSystems Introduces Advanced Magnetic and Inductive Position Sensing Solutions at Electronica 2024
- Car key in the left hand, liveness detection radar in the right hand, UWB is imperative for cars!
- After a decade of rapid development, domestic CIS has entered the market
- Aegis Dagger Battery + Thor EM-i Super Hybrid, Geely New Energy has thrown out two "king bombs"
- A brief discussion on functional safety - fault, error, and failure
- In the smart car 2.0 cycle, these core industry chains are facing major opportunities!
- The United States and Japan are developing new batteries. CATL faces challenges? How should China's new energy battery industry respond?
- Murata launches high-precision 6-axis inertial sensor for automobiles
- Ford patents pre-charge alarm to help save costs and respond to emergencies
- New real-time microcontroller system from Texas Instruments enables smarter processing in automotive and industrial applications
Guess you like