The following points should be noted when using metal rotor flowmeter

Publisher:彩虹微笑Latest update time:2012-12-03 Source: 21IC Reading articles on mobile phones Scan QR code
Read articles on your mobile phone anytime, anywhere
In order to ensure the normal operation of the metal rotor flowmeter and achieve the required measurement accuracy, the following points should generally be noted:

the metal rotor flowmeter must be installed vertically, the fluid flows through the flowmeter from bottom to top, and the verticality is better than 2°. When installed horizontally, the horizontal angle is better than 2°; the metal tube float flowmeter installed on the process pipeline should be bypassed so that the production will not be affected when handling faults or flushing; the metal rotor flowmeter should have a straight pipe section of more than 5 times the pipe diameter at the inlet and a 250mm straight pipe section at the outlet to ensure the measurement accuracy of the instrument; if the medium contains ferromagnetic substances, a magnetic filter should be installed; if the medium contains solid impurities, consideration should be given to adding a bypass between the valve and the straight pipe section. Install filters between pipe sections; when used for gas measurement, the pipeline pressure should be no less than 5 times the pressure loss of the flowmeter to ensure stable operation of the float; if the temperature of the measured medium is higher than 220℃ or the fluid temperature is too low and crystallization is easy to occur, thermal insulation protection measures should be taken, and the jacket type should be selected for cooling or heat preservation; the pipeline flange, fasteners, and sealing gaskets must be the same as the flowmeter flange standards to ensure normal installation and operation of the instrument. After the normal operation of the general device of this product, no maintenance is required. Failures often occur when the device is just started. Due to the unclean flushing of the pipeline, the float is stuck by solid particles, and the pointer of the indicator stops at one position. At this time, the valves on both sides of the flowmeter should be closed first, and then the upper flange should be removed, the float should be taken out for cleaning, and then reinstalled. Note that the nuts on the flange should be tightened evenly and the gaskets should be placed properly. In order to avoid deformation of the flowmeter caused by the pipeline, the flange of the process pipeline must be coaxial with the flange of the flowmeter and parallel to each other. Appropriate pipeline support should be provided to avoid pipeline vibration and reduce the axial load of the flowmeter. The control valve in the measurement system should be installed downstream of the flowmeter. Since the instrument transmits signals through magnetic coupling, in order to ensure the performance of the instrument, no ferromagnetic material is allowed to exist at least 10cm around the installation. The instrument for measuring gas is calibrated at a specific pressure. If the gas is discharged directly into the atmosphere at the outlet of the instrument, a pressure drop will occur at the float and cause data distortion. If this is the working condition, a valve should be installed at the outlet of the instrument. For instruments with LCD display, metal rotor flowmeters should be installed to avoid direct sunlight on the display as much as possible to avoid reducing the service life of the LCD. For instruments with battery power supply, direct sunlight and high temperature environment (≥65℃) should be avoided as much as possible to avoid reducing the capacity and life of the lithium battery.
Reference address:The following points should be noted when using metal rotor flowmeter

Previous article:Target flowmeter fault analysis and troubleshooting
Next article:Application of intelligent vortex gas flowmeter in gas fields and urban natural gas

Latest Test Measurement Articles
Change More Related Popular Components

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号