1. Introduction
As a backup power source when the power system is out of power, batteries have been widely used in industrial production, transportation, communications and other industries. If the battery fails or the capacity is insufficient, it may cause a major accident, so the operating parameters of the battery must be fully monitored online. One of the important indicators of the battery status is its internal resistance. Whether the battery is about to fail, the capacity is insufficient, or the charging and discharging is improper, it can be reflected from the change in its internal resistance. Therefore, the working status of the battery can be evaluated by measuring its internal resistance. The common methods for measuring the internal resistance of batteries are:
(1) Density method
The density method mainly estimates the internal resistance of the battery by measuring the density of the battery electrolyte. It is often used to measure the internal resistance of open lead-acid batteries, but is not suitable for measuring the internal resistance of sealed lead-acid batteries. The scope of application of this method is narrow.
(2) Open circuit voltage method
The open circuit voltage method estimates the internal resistance of the battery by measuring the terminal voltage of the battery. The accuracy is very poor and may even lead to wrong conclusions. This is because even if the capacity of a battery has become very small, its terminal voltage may still be normal when it is in the floating charge state.
(3) DC discharge method
The DC discharge method is to discharge the battery with a large current instantaneously, measure the instantaneous voltage drop on the battery, and calculate the internal resistance of the battery by Ohm's law. Although this method has been widely used in practice, it also has some disadvantages. For example, the internal resistance of the battery must be detected in a static or offline state using this method, and online measurement cannot be achieved. Moreover, large current discharge will cause great damage to the battery, thereby affecting the capacity and life of the battery.
(4) AC injection
method The AC method injects a constant AC current signal IS into the battery, measures the voltage response signal Vo at both ends of the battery, and the phase difference between the two
According to the impedance formula
To determine the internal resistance R of the battery. This method does not require discharging the battery and can achieve safe online detection of the battery internal resistance, so it will not affect the performance of the battery. However, this method requires measuring the AC current signal Is, the voltage response signal Vo, and the phase difference between the voltage and current
It can be seen that this method not only has many interference factors, but also increases the complexity of the system and affects the measurement accuracy.
In order to solve the defects of the above methods, this paper adopts a four-terminal measurement method. The voltage response signal at both ends of the battery is multiplied by the sinusoidal signal that generates a constant AC source through an AC differential circuit through an analog multiplier. The output voltage signal of the analog multiplier is then passed through a filter circuit to convert the AC signal into a DC signal. The DC signal is amplified by a DC amplifier and then converted into an analog-to-digital signal. The converted value is sent to the microcontroller for simple processing.
2. Battery internal resistance detection principle
Since the internal resistance of the battery is in the milliohm range, the conventional two-terminal measurement method has a large measurement error. In this paper, a four-terminal measurement method is used. When measuring, a frequency of
The other two terminals are used for measurement. The measurement working principle diagram is shown in Figure 1. The response signal refers to the AC voltage signal measured at both ends of the battery after the battery is injected into the AC constant current source. The sinusoidal signal is the input signal of the voltage-controlled constant current source generated by the D/A.
Assume the sinusoidal signal is:
(1)
The response voltage signal at both ends of the battery is:
(2)
It is the phase difference
between the AC current injected into the battery and the voltage signal responding at both ends of the battery.
(3)
K is the gain factor of the analog multiplier.
After low-pass filtering, the AC component is filtered out and the following is obtained:
(4)
According to the principle of measuring internal resistance by AC method:
(5)
Where I is the maximum value of the AC constant current source signal. Comparing (4) and (5), we can get:
In the above formula, K, A, and I are all known quantities, and u is the sampled value sent to the microcontroller for processing after A/D sampling, so a simple division operation in the microcontroller can obtain the internal resistance of the battery.
3. Design of AC constant current source
The prerequisite for successfully detecting the battery status is to provide the required AC constant current source. The constant current source is a power supply device that can provide a constant current to the load. It is a power supply with a very large internal resistance. In order to ensure that the internal resistance has a high measurement accuracy and good reproducibility, the constant current source is required to have sufficient stability and low waveform distortion. The AC signal amplitude required here is 40mV and the frequency is 1KHZ.
However, there are many shortcomings in the design of traditional low-frequency AC signal generators: the use of general-purpose circuits has many components, especially the capacitors are large in size, and the waveform stability is poor, the distortion is large, and the adjustment is extremely inconvenient; the use of special-purpose circuits, such as ICL8038, MAX038, etc., has obvious improvements in distortion and stability, but is not suitable for low-frequency applications, is inconvenient to adjust, and has a high cost.
3.1 Design Principles
This paper adopts a digital signal generator to generate a standard sine wave and a current negative feedback method to generate an accurate AC constant current source. The implementation principle of the AC constant current source is shown in Figure 2.
The circuit block diagram is shown in Figure 2: This is a closed-loop control system, a current negative feedback circuit. The standard sine wave generates a 1KHz sine wave signal with stable frequency, symmetry and low distortion. The drive circuit amplifies the sine wave to drive the power amplifier circuit to obtain a sinusoidal AC current output. The constant current control circuit obtains a signal from the power amplifier output and adjusts the signal of the drive circuit by comparing it with a given signal, so that the output current remains stable.
3.2 Principle of generating standard sine wave
The standard sine wave signal is generated by a digital signal generator. First, the sine table data is stored in the sine signal memory as shown in Figure 3. The crystal oscillator generates an oscillation frequency f, which is converted into a complete square wave frequency through a shaping circuit, and then passes through the R frequency division circuit to obtain a frequency of f/R. After the phase detector FD and the loop filter LF circuit are phase-locked and divided, the sine value stored in the sine signal memory is read, and the standard sine wave required by Figure 2 is generated through a D/A conversion circuit and a low-pass active filter circuit.
Figure 3 Principle block diagram of standard sine wave signal source
4. Summary
Compared with the existing technology, this processing method has a wide range of applications, high measurement accuracy, and little damage to the battery. It can safely monitor and manage the battery online. At the same time, the internal resistance of the battery can be obtained without AC sampling and solving cos. This simplifies the complexity of the software and hardware required to measure the AC voltage and phase difference at both ends of the battery in the AC injection method. This method can meet the requirements of battery detection, achieve good practical results, and complete the performance detection and fault diagnosis of lead-acid batteries. It provides a practical method for online detection of batteries.
Previous article:Introduction to IC Packaging and Device Testing Equipment
Next article:Analysis and processing of aircraft power supply performance parameter test system errors
- Popular Resources
- Popular amplifiers
- Keysight Technologies Helps Samsung Electronics Successfully Validate FiRa® 2.0 Safe Distance Measurement Test Case
- From probes to power supplies, Tektronix is leading the way in comprehensive innovation in power electronics testing
- Seizing the Opportunities in the Chinese Application Market: NI's Challenges and Answers
- Tektronix Launches Breakthrough Power Measurement Tools to Accelerate Innovation as Global Electrification Accelerates
- Not all oscilloscopes are created equal: Why ADCs and low noise floor matter
- Enable TekHSI high-speed interface function to accelerate the remote transmission of waveform data
- How to measure the quality of soft start thyristor
- How to use a multimeter to judge whether a soft starter is good or bad
- What are the advantages and disadvantages of non-contact temperature sensors?
- Innolux's intelligent steer-by-wire solution makes cars smarter and safer
- 8051 MCU - Parity Check
- How to efficiently balance the sensitivity of tactile sensing interfaces
- What should I do if the servo motor shakes? What causes the servo motor to shake quickly?
- 【Brushless Motor】Analysis of three-phase BLDC motor and sharing of two popular development boards
- Midea Industrial Technology's subsidiaries Clou Electronics and Hekang New Energy jointly appeared at the Munich Battery Energy Storage Exhibition and Solar Energy Exhibition
- Guoxin Sichen | Application of ferroelectric memory PB85RS2MC in power battery management, with a capacity of 2M
- Analysis of common faults of frequency converter
- In a head-on competition with Qualcomm, what kind of cockpit products has Intel come up with?
- Dalian Rongke's all-vanadium liquid flow battery energy storage equipment industrialization project has entered the sprint stage before production
- Allegro MicroSystems Introduces Advanced Magnetic and Inductive Position Sensing Solutions at Electronica 2024
- Car key in the left hand, liveness detection radar in the right hand, UWB is imperative for cars!
- After a decade of rapid development, domestic CIS has entered the market
- Aegis Dagger Battery + Thor EM-i Super Hybrid, Geely New Energy has thrown out two "king bombs"
- A brief discussion on functional safety - fault, error, and failure
- In the smart car 2.0 cycle, these core industry chains are facing major opportunities!
- The United States and Japan are developing new batteries. CATL faces challenges? How should China's new energy battery industry respond?
- Murata launches high-precision 6-axis inertial sensor for automobiles
- Ford patents pre-charge alarm to help save costs and respond to emergencies
- New real-time microcontroller system from Texas Instruments enables smarter processing in automotive and industrial applications
- The Three Realms of Oscilloscopes
- Problems with the snubber circuit
- [RVB2601 Creative Application Development] Introduction and use of cJSON for RVB2601
- I bought an ST-LINK emulator for SensorTile.box for 19 RMB
- Common RF Certification Systems
- [RVB2601 Creative Application Development] VII. RVB2601 Sound Recognition Preliminary Test
- Use FPGA to simulate USB function (written in VHDL language).rar
- The internal crystal oscillator of SMIC 5897 is inaccurate
- KEYENCE Fiber Optic Sensor Disassembly
- DSP28335 burning program, besides CCS software, is there any third-party program download software tool? ?