ZWQ Series
80-170W Quad Output Power Supplies
Features
Universal Input (85 - 265VAC)
Power Factor Corrected
Floating Adjustable Fourth Output
Low Profile <1U High
Key Market Segments & Applications
Specifications
Model
Input Voltage
Input Current (1)
Inrush Current (1)
Power Factor
Temperature Coefficient
Max Output Power (convection)
Max Output Power (forced air)
Overpower Protection (2)
Minimum Load
Output Voltage Accuracy
Efficiency (Typ)
Hold Up Time (1)
Leakage Current
Remote On / Off
Oper Temp (convection cooled)
Oper Temp (forced air cooled)
Storage Temperature
Humidity (non condensing)
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Approvals
Conducted & Radiated EMI
Immunity
Weight (Typ)
Size (W x H x D)
Warranty
ZWQ80
-5222
-
A
A
-
-
W
W
W
A
%
%
ms
-
-
°C
°C
°C
-
-
-
-
-
-
-
-
g
mm
yrs
ZWQ80
ZWQ80 ZWQ130 ZWQ130 ZWQ130 ZWQ130
-5224
-5225
-5222
-5223
-5224
-5225
85-265VAC (47-63Hz), 120-370VDC*
1.6 / 0.8
2.6 / 1.3
14/28
Meets EN61000-3-2
<0.02%/°C
80
130
104
88.7
104
104
170
149.6
170
170
>109
>93
>109
>109
>173
>152
>173
>173
V1: 0.9A Conv, 1.4A Forced Air
V1: 1.5A Conv, 2.1A Forced Air
±5% for outputs V2 and V3
72
20
0.75mA max, 0.2mA (Typ) at 100VAC / 0.44mA(Typ) at 230VAC
See installation manual (Not available with /A cover option)
-10°C to 60°C, derate linearly to 50% load from 40°C to 60°C. (3)
-10°C to 70°C, derate linearly to 50% load from 50°C to 70°C. (>30cfm airflow)(3)
-30° to +85°C
Operating: 30 - 90% RH; Non-operating 10-95% RH
I/P~Grnd 2kVAC (20mA), I/P~O/P 3kVAC (20mA), O/P~Grnd 500VAC (100mA) for 1 min.
>100M at 25°C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s
2
constant X, Y, Z 1 hour
< 196.1 m/s
2
UL60950-1, CSA60950-1, EN60950-1, CE Mark, EN50178
EN55011, EN55022-B, FCC Class B, VCCI-B
EN61000-4-2,-3,-4,-5,-6,-8,-11
550
730
93.5 x 35 x 210 (refer to outline drawing)
106 x 35 x 225 (refer to outline drawing)
One Year
*Safety certified for AC input only
ZWQ80
-5223
(1) 100/200VAC
(2) Avoid prolong operation in overload
(3) /A version - additional derating, see installation manual
1-800-526-2324 • www.us.tdk-lambda.com/lp/
85
Disclaimer: us.tdk-lambda.com/lp/legal.htm
ZWQ Series
Model Selector
Voltage
Peak or
Max
Max
Ripple
Adjust
Convect. Forced Air Load Reg Line Reg Noise
Model
Output
Voltage (V)
Range (V)
(A)
(A)(4)
(mV)
(mV)
(mV)
ZWQ80-5222
V1
5
5.0-5.25
8.0
10.0
100
20
120
V2
+12/15*
+12/+15
2.0
2.5
300
48
150
V3
-12/15*
-12/-15
2.0
2.5
300
48
150
V4
12
11.4-12.6
3.0
4.0
300
48
150
ZWQ80-5223
V1
5
5.0-5.25
8.0
10.0
100
20
120
V2
+12/15*
+12/+15
2.0
2.5
300
48
150
V3
-12/15*
-12/-15
2.0
2.5
300
48
150
V4
3.3
2.0-3.63
7.0
9.0
100
20
120
ZWQ80-5224
V1
5
5.0-5.25
8.0
10.0
100
20
120
V2
+12/15*
+12/+15
2.0
2.5
300
48
150
V3
-12/15*
-12/-15
2.0
2.5
300
48
150
V4
24
22.8-25.2
1.5
2.0
400
96
200
ZWQ80-5225
V1
5
5.0-5.25
8.0
10.0
100
20
120
V2
+12/15*
+12/+15
2.0
2.5
300
48
150
V3
-12/15*
-12/-15
2.0
2.5
300
48
150
V4
5
2.0-5.25
7.0
9.0
100
20
120
ZWQ130-5222
V1
5
5.0-5.25
15.0
19.0
100
20
120
V2
+12/15*
+12/+15
4.0
5.0
300
48
150
V3
-12/15*
-12/-15
4.0
5.0
300
48
150
V4
12
11.4-12.6
4.0
5.0
300
48
150
ZWQ130-5223
V1
5
5.0-5.25
15.0
19.0
100
20
120
V2
+12/15*
+12/+15
4.0
5.0
300
48
150
V3
-12/15*
-12/-15
4.0
5.0
300
48
150
V4
3.3
2.0-3.63
10.0
12.0
100
20
120
ZWQ130-5224
V1
5
5.0-5.25
15.0
19.0
100
20
120
V2
+12/15*
+12/+15
4.0
5.0
300
48
150
V3
-12/15*
-12/-15
4.0
5.0
300
48
150
V4
24
22.8-25.2
2.0
2.5
400
96
200
ZWQ130-5225
V1
5
5.0-5.25
15.0
19.0
100
20
120
V2
+12/15*
+12/+15
4.0
5.0
300
48
150
V3
-12/15*
-12/-15
4.0
5.0
300
48
150
V4
5
2.0-5.25
10.0
12.0
100
20
120
* User selectable via connector or PCB. Outputs are floating from V1 & V4. Can be connected in series for 24/30V.
OVP
(V)(5)
5.7-7.0
16.5-22.5
16.5-22.5
13.8-16.2
5.7-7.0
16.5-22.5
16.5-22.5
3.79-4.95
5.7-7.0
16.5-22.5
16.5-22.5
27.6-32.4
5.7-7.0
16.5-22.5
16.5-22.5
5.7-7.0
5.7-7.0
16.5-22.5
16.5-22.5
11.4-12.6
5.7-7.0
16.5-22.5
16.5-22.5
3.79-4.95
5.7-7.0
16.5-22.5
16.5-22.5
27.6-32.4
5.7-7.0
16.5-22.5
16.5-22.5
5.7-7.0
Other Industrial Products
ZWS/ZWD
SC
NV
HWS
5W to 480W Single and dual output
30W to 120W Single, dual, & triple output
175 to 700W Single and multiple output
15 to 1500W Single output
Options
Suffix
blank
/L
/A
Description
No cover or L Bracket
L Bracket
Cover and L Bracket
(4) The peak current draw must not exceed a 10 sec. duration with a
duty cycle of 35%.
(5) An overvoltage condition on any output will shut down all outputs,
the power supply must be re-set by cycling the AC input.
For Additional Information, please visit
us.tdk-lambda.com/lp/products/zwq-series.htm
1-800-526-2324 • www.us.tdk-lambda.com/lp/
86
Revision A5: Apr 2015