EEWORLDEEWORLDEEWORLD

Part Number

Search

VI-J7X-CY

Description
Isolated DC/DC Converters VI J00/200 - 165 Vin, 5.2 Vout, 50 W, C Product Grade
CategoryPower/power management    The power supply circuit   
File Size655KB,8 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Download Datasheet Parametric View All

VI-J7X-CY Online Shopping

Suppliers Part Number Price MOQ In stock  
VI-J7X-CY - - View Buy Now

VI-J7X-CY Overview

Isolated DC/DC Converters VI J00/200 - 165 Vin, 5.2 Vout, 50 W, C Product Grade

VI-J7X-CY Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerVICOR
Reach Compliance Codenot_compliant
ECCN codeEAR99
Other featuresCAN BE OPERATED AT 300V NOMINAL INPUT ALSO
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage375 V
Minimum input voltage100 V
Nominal input voltage150 V
JESD-30 codeR-XDMA-P9
JESD-609 codee0
Maximum load regulation0.2%
Number of functions1
Output times1
Number of terminals9
Maximum operating temperature100 °C
Minimum operating temperature-25 °C
Maximum output voltage5.72 V
Minimum output voltage2.6 V
Nominal output voltage5.2 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelOTHER
Terminal surfaceTIN LEAD OVER COPPER
Terminal formPIN/PEG
Terminal locationDUAL
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output50 W
Fine-tuning/adjustable outputYES
Half Brick, DC-DC Converters
VI-J00
VE-J00
®
S
C
US
C
NRTL
US
25 to 100 Watts
Features & Benefits
Isolated output
Up to 50W/in
3
cURus, cTÜVus
CE Marked
Up to 90% efficiency
Size: 2.28” x 2.4” x 0.5”
(57,9 x 61,0 x 12,7mm)
Remote sense and current limit
Logic disable
Wide range output adjust
ZCS power architecture
Low noise FM control
RoHS compliant (VE verisons)
Product Highlights
The VI-J00 MiniMod family established a new standard in component-level DC-DC
converters. This “junior” size complement to the higher power VI-200 family offers up
to 100W of isolated and regulated power in a board mounted package. With thousands
of input/output/power combinations, and with a maximum operating temperature
rating of 100°C, the MiniMod provides nearly unlimited flexibiliy for power system
designers to meet demanding time to market requirements.
Utilizing Vicor’s “zero-current-switching” forward converter technology, proven
by an installed base of over 8 million units, the MiniMod family combines state of
the art power density with the efficiency, low noise and reliability required by next
generation power systems.
Part Numbering
VI
J
6
1
C
W
Family
VI
=Non-RoHS
VE
= RoHS
Series
J
= J00
0
= 12V
V
= 24V
1
= 24V
W
= 24V
2
= 36V
3
= 48V
Input
N
= 48V
4
= 72V
T
= 110V
5
= 150V
6
= 300V
7
= 150/300V
Z
= 2V
Y
= 3.3V
0
= 5V
X
= 5.2V
W
= 5.5V
V
= 5.8V
T
= 6.5V
R
= 7.5V
Output
M
= 10V
1
= 12V
P
= 13.8V
2
= 15V
N
= 18.5V
3
= 24V
L
= 28V
J
= 36V
K
= 40V
4
= 48V
H
= 52V
F
= 72V
D
= 85V
B
= 95V
Grade
E
= –10 to 100°C
I
= – 40 to 100°C
M
= –55 to 100°C
≥ 5V
Power
< 5V
W
= 20A
X
= 15A
Y
= 10A
Z
= 5A
C
= –25 to 100°C
W
= 100W
X
= 75W
Y
= 50W
Z
= 25W
Note:
For additional
packaging options,
please see page 5.
VI-J00 DC-DC Converters
Page 1 of 7
Rev 3.0
06/2017
Tailing Micro B91 Development Kit --- Testing Power Consumption in BLE Connections
[i=s]This post was last edited by xiaolinen on 2022-10-12 22:08[/i]1. Narrative This test was conducted according to the Telink B91 BLE Single Connection SDK Developer Handbook document, mainly to mea...
xiaolinen RF/Wirelessly
Application areas of Bluetooth Low Energy
[size=3]For more than a decade, Bluetooth has played an important role in the field of short-range wireless communications. Whether it is mobile phones, tablets, PCs, headphones, game controllers, spe...
Jacktang Wireless Connectivity
During the fight against the epidemic, we will teach you how to have instruments in your mind without having any in your hands.
In the past few days, all engineers have received news that they can work remotely from home.With the wave of resumption of work during the COVID-19 pandemic, remote work has become very necessary. We...
eric_wang Integrated technical exchanges
Migrating between TMS320F28004x and TMS320F28002x
This migration guide describes the hardware and software differences to be aware of when migrating between the F28004x and F28002x C2000 MCUs. This document provides block diagrams of the two MCUs to ...
fish001 Microcontroller MCU
K210 performance test again
使用Loboris的K210版本,进行了一次计算性能测试,供大家参考。[table] [tr=rgb(230, 230, 230)][td] [/td][td][b]MCU[/b][/td][td][align=left][b]Freq[/b][/align][/td][td][align=center][b]Int Add[/b][/align][/td][td][align=center][b...
dcexpert MicroPython Open Source section
5G high-frequency board material selection and multi-layer board design requirements
5G high-frequency board material selection and multi-layer board design requirements...
deamxiao PCB Design

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号