Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25° if not specified separately.
C,
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40° and +50° For use in outside this temperature range, derating is needed.
C
C.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL CC1R5-1203Sx-E CC1R5-1205Sx-E
CC1R5-1212Sx-E
CC1R5-1212Dx-E
ITEMS/UNITS
Nominal Voltage
V
DC12
Voltage Range
V
DC9.0-18
Input
Efficiency (typ)
(*1)
%
73
78
82
81
Current (typ)
(*1) A
0.151
0.160
0.152
0.154
Nominal Voltage
VDC
3.3
5
12
15
12
15
Maximum Current
A
0.400
0.300
0.125
0.100
0.060
0.050
Maximum Power
(*2) W
1.32
1.5
Maximum Line Regulation (Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature–40° to +50°
C
C)
Max Power Total Regulation (max) (*4)
%
3
±
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
VDC
3.15-3.6
4.75-6.0
11.4-15.0
11.4 - 15.0
Voltage Adjustable Range
Over Current Protection
(*6)
Available
Function Over Voltage Protection
Not available
Remote ON/OFF Control
Available
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
℃
-40 to +85
%
RH
5-95 (the conditions of maximum 38° in wet bulb temperature and non-condensation should be ensured.)
C
Operating Ambient Humidity
Environment
Storage Ambient Humidity
%
RH
5-95 (the conditions of maximum 38° in wet bulb temperature and non-condensation should be ensured.)
C
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Isolation Resistance
Between input terminal and output terminal: 500VDC, 50MΩ min
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25° if not specified separately.
C,
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40° and +50° For use in outside this temperature range, derating is needed.
C
C.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
・All specifications are subject to change without notice.
2
CC1R5-E
3
MODEL CC1R5-2403Sx-E CC1R5-2405Sx-E
CC1R5-2412Sx-E
CC1R5-2412Dx-E
ITEMS/UNITS
Nominal Voltage
V
DC24
Voltage Range
V
DC18-36
Input
Efficiency (typ)
(*1)
%
72
77
81
79
Current (typ)
(*1) A
0.076
0.081
0.077
0.079
Nominal Voltage
VDC
3.3
5
12
15
12
15
Maximum Current
A
0.400
0.300
0.125
0.100
0.060
0.050
Maximum Power
(*2) W
1.32
1.5
Maximum Line Regulation (Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature–40° to +50°
C
C)
Max Power Total Regulation (max) (*4)
%
3
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
VDC
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Voltage Adjustable Range
Over Current Protection
(*6)
Available
Not available
Function Over Voltage Protection
Remote ON/OFF Control
Available
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
℃
-40 to +85
Operating Ambient Humidity
%
RH
5-95 (the conditions of maximum 38° in wet bulb temperature and non-condensation should be ensured.)
C
Environment
Storage Ambient Humidity
%
RH
5-95 (the conditions of maximum 38° in wet bulb temperature and non-condensation should be ensured.)
C
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Isolation Resistance
Between input terminal and output terminal: 500VDC, 50MΩ min
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25° if not specified separately.
C,
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40° and +50° For use in outside this temperature range, derating is needed.
C
C.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL CC1R5-4803Sx-E CC1R5-4805Sx-E
CC1R5-4812Sx-E
CC1R5-4812Dx-E
ITEMS/UNITS
Nominal Voltage
V
DC48
Voltage Range
V
DC36-76
Input
Efficiency (typ)
(*1)
%
70
76
80
79
Current (typ)
(*1) A
0.039
0.041
0.039
0.040
Nominal Voltage
VDC
3.3
5
12
15
12
15
Maximum Current
A
0.400
0.300
0.125
0.100
0.060
0.050
Maximum Power
(*2) W
1.32
1.5
Maximum Line Regulation (Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature–40° to +50°
C
C)
Max Power Total Regulation (max) (*4)
%
3
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
VDC
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Voltage Adjustable Range
Over Current Protection
(*6)
Available
Not available
Function Over Voltage Protection
Remote ON/OFF Control
Available
℃
-40 to +85
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
%
RH
5-95 (the conditions of maximum 38° in wet bulb temperature and non-condensation should be ensured.)
C
Operating Ambient Humidity
Environment
%
RH
5-95 (the conditions of maximum 38° in wet bulb temperature and non-condensation should be ensured.)
C
Storage Ambient Humidity
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Between input terminal and output terminal: 500VDC, 50MΩ min
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25° if not specified separately.
C,
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40° and +50° For use in outside this temperature range, derating is needed.
C
C.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
・All specifications are subject to change without notice.
CC1R5-E
Outline Drawing
CC1R5-xxxxxF-E (DIP type)
Shape/Dimensions
8.5max.
4
16.6±0.2
Recommended measurements for
mounting board
4.0
14.605
2.92
Outer shape of
product
16.51
2.54
(3.22)
0.5
1.905
a
3
2
7.62
12.7
1.905
b
4
5
a
2.7
13.08
12.7
7-ø1.0 (land diameter ø2.0)
2-ø1.5 (land diameter ø2.5)
3.5
2.54 5.08 2.54
16.51
1.0
b
0.5
7-0.3×0.6
1
b
6
7
a
2.7
CC1R5-xxxxxR-E (SMD type)
Shape/Dimensions
8.8max.
(3.22)
Unit: mm
Allowable tolerance is ±0.5 if not specified separately.
16.6±0.2
Recommended measurements for
mounting board
4.0
(3.22)
Outer shape of
product
2.54 5.08 2.54
3.2
3.5
t=0.3
10.16
7.62
t=0.3
(13.38)
16.51
Coplanarity: 0.1 or lower
1.8
19.81
1.8
2.54
(3.22)
3.2
15.6
22.0
2
7.62
5
7-0.3×0.6
6
7
(3.22)
1
2.54 5.08 2.54
3
4
Unit: mm
Allowable tolerance is ±0.5 if not specified separately.
Connection diagram
CC1R5-xxxxSx-E
+Vin
1
7
6
RC
–Vin
5
2
3
+Vout
Terminal connections
No.1
No.2
No.3
No.4
No.5
No.6
No.7
+Vin
RC
–Vin
NC
–Vout
TRM
+Vout
Load
CC1R5-xxxxDx-E
+Vin
1
7
6
RC
–Vin
5
2
3
4
+Vout
Terminal connections
No.1
No.2
No.3
No.4
No.5
No.6
No.7
+Vin
RC
–Vin
–Vout
Common out
TRM
+Vout
Load
TRM
–Vout
TRM
COM
–Vout
4 NC
Derating Curve
100
Output power (%)
80
60
40
20
Natural air cooling
a
b
a:
0.5m/s
(100LFM)
b:
1m/s
(200LFM)
Ambient temperature (°
C)
0
-40 -20 0 20 40 60 80 100
Output power derating by ambient temperature
(common specification)
・All specifications are subject to change without notice.
2.54 5.08 2.54
10.16
7.62
1.2
Load
(DIP/SMD)
CC3-E
CC3-E Specifications
MODEL CC3-0503Sx-E
CC3-0505Sx-E
CC3-0512Sx-E
CC3-0512Dx-E
ITEMS/UNITS
Nominal Voltage
V
DC5.0
Voltage Range
V
DC4.5-9.0
Input
Efficiency (typ)
(*1)
%
73
77
82
81
Current (typ)
(*1) A
0.723
0.779
0.732
0.741
VDC
3.3
5
12
15
12
15
Nominal Voltage
Maximum Current
A
0.800
0.600
0.250
0.200
0.125
0.100
Maximum Power
(*2)
2.64
3
Maximum Line Regulation(Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature -40℃ to +50℃ )
Max Power Total Regulation (max) (*4)
%
3
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
Voltage Adjustable Range
VDC
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Over Current Protection
(*6)
Available
Function Over Voltage Protection
Not available
Remote ON/OFF Control
Available
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
℃
-40 to +85
Operating Ambient Humidity
%
RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
Environment
Storage Ambient Humidity
%
RH
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each
Vibration
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Isolation Resistance
Between input terminal and output terminal: 500VDC, 50MΩ min
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25° if not specified separately.
C,
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40° and +50° For use in outside this temperature range, derating is needed.
C
C.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL CC3-1203Sx-E
CC3-1205Sx-E
CC3-1212Sx-E
CC3-1212Dx-E
ITEMS/UNITS
Nominal Voltage
V
DC12
Voltage Range
V
DC9.0-18
Input
Efficiency (typ)
(*1)
%
74
79
82
81
Current (typ)
(*1) A
0.297
0.316
0.305
0.309
Nominal Voltage
VDC
3.3
5
12
15
12
15
Maximum Current
A
0.800
0.600
0.250
0.200
0.125
0.100
Maximum Power
(*2) W
2.64
3
Maximum Line Regulation(Within input voltage range) mV
20
40
80
Maximum Load Regulation (0-100% load) (*3) mV
40
100
600
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature -40℃ to +50℃ )
Max Power Total Regulation (max) (*4)
%
3
5
Maximum Ripple & Noise (typ/max) (*5) mVp-p
40/120
30/120
VDC
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Voltage Adjustable Range
Over Current Protection
(*6)
Available
Not available
Function Over Voltage Protection
Remote ON/OFF Control
Available
℃
-40 to +85
Operating Ambient Temperature
℃
-40 to +85
Storage Ambient Temperature
%
RH
5-95 (the conditions of maximum 38° in wet bulb temperature and non-condensation should be ensured.)
C
Operating Ambient Humidity
Environment
%
RH
5-95 (the conditions of maximum 38° in wet bulb temperature and non-condensation should be ensured.)
C
Storage Ambient Humidity
Vibration
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each
Shock
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation
Isolation Resistance
Between input terminal and output terminal: 500VDC, 50MΩ min
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25° if not specified separately.
C,
Note: For 12V/±12V models, output voltage can be set to 15V/±15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°
C.
(*2) The maximum output power value is between -40° and +50° For use in outside this temperature range, derating is needed.
C
C.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°
C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
・All specifications are subject to change without notice.