EEWORLDEEWORLDEEWORLD

Part Number

Search

PAA600F-24

Description
Switching Power Supplies 600W 24V 27A AC-DC Power Supply
CategoryPower/power management   
File Size423KB,13 Pages
ManufacturerCosel
Download Datasheet Parametric View All

PAA600F-24 Online Shopping

Suppliers Part Number Price MOQ In stock  
PAA600F-24 - - View Buy Now

PAA600F-24 Overview

Switching Power Supplies 600W 24V 27A AC-DC Power Supply

PAA600F-24 Parametric

Parameter NameAttribute value
Product CategorySwitching Power Supplies
ManufacturerCosel
RoHSDetails
ProductSwitching Supplies
Output Voltage-Channel 124 V
Number of Outputs1 Output
Output Power648 W
Open Frame/EnclosedEnclosed
Input Voltage85 VAC to 264 VAC/120 VDC to 340 VDC
Output Current-Channel 127 A
Commercial/MedicalCommercial
Isolation Voltage3 kV
Mounting StyleChassis
Length200 mm
Width190 mm
Height92 mm
Input Frequency50 Hz/60 Hz
Load RegulationRegulated
Power - Forced Air648 W
Factory Pack Quantity3
Unit Weight8.818 lbs
AC-DC Power Supplies Enclosed type
Ordering information
PAA
PAA50F
R
PAA
1
2
50
3
F
4
-5
5
-O
1Series
name
2Output
wattage
3Universal
input
4Output
voltage
5Optional
*4
C :with Coating
G :Low leakage current
J :Connector type
N :with Cover
R :with Remote ON/OFF
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The
EMI/EMC Filter is recommended
*to
connect with several devices.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PAA50F-3
30
3V 10A
PAA50F-5
50
5V 10A
PAA50F-12
51.6
12V 4.3A
PAA50F-15
52.5
15V 3.5A
PAA50F-24
52.8
24V 2.2A
PAA50F-48
52.8
48V 1.1A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%]
POWER FACTOR
ACIN 100V
ACIN 200V
PAA50F-3
PAA50F-5
PAA50F-12
PAA50F-15
PAA50F-24
PAA50F-48
AC85 - 264 1
f
0.5typ
0.8typ
0.25typ
0.4typ
50/60 (47 - 63)
67typ
74typ
77typ
78typ
80typ
80typ
0.95typ (Io=100%)
15typ (Io=100%)
15typ (Io=100%)
0.75max (60Hz, According to UL, CSA, VDE and DEN-AN)
3
5
12
15
24
48
10
10
4.3
3.5
2.2
1.1
20max
20max
48max
60max
96max
192max
40max
40max
100max
120max
150max
240max
80max
80max
120max
120max
120max
150max
140max
140max
160max
160max
160max
200max
120max
120max
150max
150max
150max
250max
160max
160max
180max
180max
180max
300max
50max
50max
120max
150max
240max
480max
60max
60max
150max
180max
290max
600max
20max
20max
48max
60max
96max
192max
500max (ACIN 85V, Io=100%)
10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%) 100typ (ACIN 200V, Io=100%)
2.85 - 3.6
t
10%
Works over 105% of rating and recovers automatically
4.00 - 5.25V
Works at 115 - 140% of rating
LED (Green)
Optional (Refer to Instruction Manual)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
AC100V 1minute, Cutoff current = 100mA, DC100V 10M
W
min (At Room Temperature)
-10 to +65
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
Complies with IEC61000-3-2
37
X
85
X
159mm (without terminal block) (W
X
H
X
D) /400g max (without cover)
Convection
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*3
*4
*
ACIN 100V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50
C
*
1
RIPPLE[mVp-p]
-10 - 0
C
*
1
0 to +50
C
*
1
RIPPLE NOISE[mVp-p]
-10 - 0
C
*
1
0 to +50
C
TEMPERATURE REGULATION[mV]
-10 to +50
C
*
2
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
OPERATING INDICATION
REMOTE ON/OFF
*
3
INPUT-OUTPUT
-
RC
INPUT-FG
*
3
OUTPUT
-
RC-FG
*
3
OUTPUT-RC
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
According to 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
Drift is change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Applicable when Remote ON/OFF(optional) is added.
Please contact us about safety approvals for the model with option.
Derating is required when operated with case cover.
PAA-2

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号