Packard Electric Metri-Pack 150 Series, 12” 20” AWG leads
1/4-18 NPT (external), 3/8-24 UNF-2A (male) *
1
303 Stainless Steel
0.5 - 4.5 VDC
Attributes
▀
▀
▀
▀
▀
▀
▀
▀
▀
▀
Typical Applications
▀
▀
▀
▀
▀
▀
▀
▀
▀
Dry Media *
2
Superior Long Term Stability
Excellent Repeatability/Hysteresis
Superior EMI/RFI Rejection
Low Power Consumption
Linear Output
Temperature Compensated
Over-Voltage, Reverse Polarity & Short Circuit Protection
Ten Million Cycle Life Expectancy
Outstanding Shock & Vibration Performance
Steam Sterilizers
Gasoline & Diesel Engines
Natural Gas & CNG Engines
Agricultural Chemical Equipment
Level Measurement
Test Equipment
Injection Molding
Coolant Pressure
Industrial Compressors
2. For wet conductive media please contact us
Description
The model P265 is based on Kavlico’s field proven ceramic capacitive technology with the latest state-of-the-art
ASIC. Featuring a 303SS housing, the P265 is designed for general use wherever a rugged and reliable pressure
transducer is required. The P265 package has a built-in MetriPack 150, electrical connector and supports
popular process connection threads. The P265 is offered with a variety of seal materials and is suitable for many
diverse applications. Specifically intended for OEM applications, the P265 delivers a cost effective solution
without compromising performance or reliability.
www.kavlico.com
Technical Specifications
Pressure Ranges
From 0 to …
PSIA,
PSIG, 1 5
PSIS
PSIA, 75
PSIG,
PSIS
PSIA, 1000
PSIG,
PSIS
20
100
30
150
50
250
75
375
100
300
150
450
200
600
300
900
500
1500
750
1500
1000
2000
Proof pressure
1000
1000
1000
1000
2000
2000
2000
2000
2000
2000
2000
Burst pressure
Physical
Operating Life Cycle
Vibration Resistance
Shock Resistance
Drop Test
Weight
Ingress Protection
Operating Temperature
Storage Temperature
Media
2. for more details see How to Order
min. 10 million full pressure cycles over the full range
10 G’s peak to peak sinusoidal (10 to 2000 Hz)
75 G’s ½ sinewave
1 meter drop on concrete as per SAE J1455 / DIN EN 60068-2-3-1
≤
100 grams (without mating connector)
IP 65 or IP67 - depending on electrical connector
-40°C to 125°C (depending on seal material) *
2
-40°C to 125°C (depending on seal material) *
2
All class II fluids and gases compatible with stainless steel 303 and the internal seal
ring material
Performance
Total error band *
3
Stability coefficient
Temp. Coefficients - Zero
Temp. Coefficients - Span
+/-2% of span (-20
≤
T
≤
100° C) +/-3% of span (T < -20° C,T < 100° C)
+/-0.5 % of full span over 1 year
0.2 % of span / 10 K within temperature range 0°C to + 80°C.2 %
0.2 % of span / 10 K within temperature range 0°C to + 80°C.2 %
3. Including non-linearity, hysteresis, non-repeatability, zero point and full scale error (corresponds to error of measurement per IEC 61298-2). Adjusted in vertical mounting position with pressure port down
www.kavlico.com
Data Sheet P265
2
Electrical
Output Signal
Operating Supply Signal
Power Consumption
Overvoltage Protection
Short-circuit Proofness
Insulation Voltage
Reverse Polarity Protection
Load
Response Time
4. for min. 3 intervals at 5 minutes each
5. for min. 10 seconds on assigned pins
0.5…4.5 VDC Ratiometric
5 VDC ± 10%
≤
25 mW
16 VDC
Yes
*4
500 VDC
Yes *
5
≥
25 kΩ
15 ms max. to 63% of full scale pressure with step change on input
Approvals & Certificates
ROHS
2011/65/EU ROHS Directive
www.kavlico.com
Data Sheet P265
3
Dimensions
Before installation and operation, ensure that the appropriate pressure sensor has been selected in terms of pressure range, design and specific measuring
conditions. Non-compliance can result in serious injury and/or damage to the equipment.
Warning:
The product information contained in this catalogue is given purely as information and does not constitute a representation, warranty or any form
of contractual commitment. Kavlico reserve the right to modify their products without notice. It is imperative that we should be consulted over any particular
use or application of our products and it is the responsibility of the buyer to establish, particularly through all the appropriate tests, that the product is suitable
for the use or application. Under no circumstances will our warranty apply, nor shall we be held responsible for any application (such as any modification,
addition, deletion, use in conjunction with other electrical or electronic components, circuits or assemblies, or any other unsuitable material or substance)
which has not been expressly agreed by us prior to the sale of our products.
www.kavlico.com
Data Sheet P265
4
How to Order
Seal Material
B Nitrile
C Neoprene
D Fluorocarbon
E Fluorosilicone
F Ethylene Propylene
Pressure Connection (port)
1 1/4 - 18 NPT (External Threads)
2 3/8 - 24 UNF-2A (Male)
3 3/8 - 24 UNF-2B (Female)
4 1/8 - 27 NPT
P265
500
S
Reference
A Absolute
G Gage
S Sealed Gage
F
1
A
Pressure Ranges
0 - 15 PSI
15
0 - 20 PSI
0 - 30 PSI
0 - 50 PSI
0 - 75 PSI
0 - 100 PSI
0 - 150 PSI
0 - 200 PSI
0 - 300 PSI
0 - 500 PSI
0 - 750 PSI
0 - 1000 PSI
20
30
50
75
100
150
200
300
500
750
1000
Built-in Electrical Connection
A Packard with Mating Connector
B 12”, 18 AWG Leads
C Packard without Mating Connector
Example:
P265-500-S-F-1-A
Description:
P265 Pressure Transmiter, 0-500 PSIS (Sealed Gage), with Ethylene Propylene Seal Material, 1/4 - 18 NPT
Pressure Connection and Mating Connector
Before installation and operation, ensure that the appropriate pressure sensor has been selected in terms of pressure range, design and specific measuring
conditions. Non-compliance can result in serious injury and/or damage to the equipment.
Warning:
The product information contained in this catalogue is given purely as information and does not constitute a representation, warranty or any
form of contractual commitment. Kavlico reserve the right to modify their products without notice. It is imperative that we should be consulted over any
particular use or application of our products and it is the responsibility of the buyer to establish, particularly through all the appropriate tests, that the product
is suitable for the use or application. Under no circumstances will our warranty apply, nor shall we be held responsible for any application (such as any
modification, addition, deletion, use in conjunction with other electrical or electronic components, circuits or assemblies, or any other unsuitable material or
substance) which has not been expressly agreed by us prior to the sale of our products.
2021 is over. At the beginning of the year, I went to the operating room equipment room on duty according to work arrangements. This year, after continuous exploration, I summarized my own set of equi...
Today, I was learning Linux and was talking about files. I saw a function that everyone should use frequently, which is formatting. Whether you format a USB flash drive, an SD card, or a hard drive, d...
[i=s]This post was last edited by sylar^z on 2019-8-11 21:19[/i]This pedometer bracelet design is based on the F103 core board and the X-NUCLEO-IKS01A3 sensor development board. The wake-up function i...
sylar^zST Sensors & Low Power Wireless Technology Forum
Recruiting MBSE part-time training instructors
Short-term training can be done on weekends. If you want to earn some extra money, accumulate resources, and enrich your life, please contact me.Require:...
First of all, I would like to thank Qinheng and EEWORLD for providing such an opportunity.Then I am sorry that I have delayed posting it until now.Let's get to the point. Let's first open the official...
The two are essentially the same, that is, digital ground and analog ground are both ground. To understand why they need to be separated, let's listen to a story first; our company's business building...