Compact Non-contact Door Switch
D40B
Detects the open/
closed state of doors
without making
contact and has high
resistance to the
environment.
• Detects the open/closed state of doors
without making contact by combining a
special magnetic actuator and switch.
The switching mechanism is not easily
disabled.
• The non-contact operation prevents
the creation of particles due to abra-
sion.
• The actuator and switch can be
washed in water. There are no key-
holes where dirt can accumulate, mak-
ing it easy to keep machinery clean.
• Small distortions in the door and me-
chanical discrepancies can be ab-
sorbed in the allowable operating range
of the magnetic actuator and switch.
• Conforms to Category 3.
Model Number Structure
Model Number Legend
Sensor
Controller
D40B-@@@@
1 2 3 4
1. Type
1: Standard Sensor
2: Elongated Sensor
3: High-temperature Type Sensor
2. Auxiliary Output
B: None
D: 1 NC
E: 1 NO
3. Cable Length
3:
3m
5:
5m
10: 10 m
4. Wiring Method
None: Pre-wired
C:
Connector (switch side only)
D40B-J@
1
1. Type
1: One main contact + one auxiliary contact (See note.)
2: Two main contacts + one auxiliary contact (See note.)
Note: The auxiliary contacts use non-safety output.
F3SL
G-197
D40B
Ordering Information
List of Models
Sensors (Switches/Actuators)
Classification
Standard Sensor
Shape
Auxiliary output
None
3m
10 m
1 NC
3m
10 m
None
3m
Cable length
Model
D40B-1B3
D40B-1B10
D40B-1D3
D40B-1D10
D40B-2B3
W
×
H
×
D: 48
×
25
×
12
Elongated Sensor
10 m
D40B-2B10
1 NC
3m
D40B-2D3
10 m
D40B-2D10
W
×
H
×
D: 19
×
82
×
19
High-temperature Type
Sensor
1 NC
5m
D40B-3D5C
1 NO
D40B-3E5C
W
×
H
×
D: 33.5
×
78.5
×
16
Note:
A Sensor used in combination with a Controller is classified Category 3.
Controllers
Safety contacts
1 NO
2 NO
Auxiliary contacts/output
(See note 2.)
1 NC (See note 1.)
1 NC
Rated voltage
24 VAC/VDC
24 VAC/VDC
110/230 VAC
Model
D40B-J1
D40B-J2
Note: 1.
MOS output.
2.
Non-safety output.
Accessories
Classification
Fuse
D9M-P1
Model
G-198
Safety Sensors / Components
Specifications
Sensor (Switch/Actuator)
Item
Switching distance (See note 1.)
(nominal value)
Actuator approach speed (See note 2.)
Operating temperature
Operating humidity
Degree of protection
Material
Mounting method
Mounting screw tightening torque
Type
Standard Sensor
OFF→
ON: 5 mm
ON→
OFF: 15 mm
17 mm/s min.
−
to +55°C
10
90% at +50°C
IP67
ABS
M4 screws
1 N·m
Stainless steel
−
to +125°C
25
Elongated Sensor
High-temperature Type
Sensor
OFF→
ON: 9 mm
ON→
OFF: 17 mm
Note: 1.
These values represent the distances at which OFF changes to ON (approaching) or ON changes to OFF (separating) when the switch
and actuator's target marks are aligned and the sensing surfaces have the same orientation.
2.
If the approach speed is less than the specified value, the Controller's safety contact output may not turn ON, even if the distance is less
than the switching distance.
Controller
Ratings
Power Supply
Item
Power supply voltage
Allowable voltage range
Power consumption
Type
24 VAC/DC
Power supply voltage ±15%
2.0 VA max.
4.0 VA max.
D40B-J1
D40B-J2
24 VAC/DC or 110/230 VAC (selectable)
Switch
Item
Rated load
Type
Safety contacts
Auxiliary contacts/output
(See note.)
D40B-J1
250 VAC, 4 A, cosφ = 1
30 VDC, 2 A, cosφ = 1
230 VAC, 100 mA, cosφ = 1
24 VDC, 100 mA, cosφ = 1
250 VAC, 4 A, cosφ = 1
30 VDC, 2 A, cosφ = 1
D40B-J2
Note:
D40B-J1: MOS output; D40B-J2: Contact output.
Characteristics
Item
Contact resistance
Auxiliary output ON resistance
Response time
Insulation resistance
Dielectric
strength
Between output poles
Between inputs and outputs
Between power supply and out-
puts
Vibration resistance
Shock resistance
Durability
Mechanical
Electrical
Minimum rated current for safety contacts
Operating temperature
Operating humidity
Mounting method
Terminal screw tightening torque
Weight
10 to 55 Hz, 1-mm single amplitude, IEC68-2-6
1,000,000 operations min.
100,000 operation min. (at the rated load)
10 VAC/VDC, 10 mA (reference values)
−
to +55 °C
10
90% at +50 °C.
35 mm DIN Track (Screw mounting is not possible.)
1 N·m
147 g
590 g
D40B
30G, 11 ms, IEC68-2-27
Type
D40B-J1
100 mΩ (not including auxiliary output)
36
Ω
(nominal value)
25 ms max.
100 MΩ (at 500 VDC)
1,500 VAC 1 min.
100 mΩ
---
D40B-J2
F3SL
G-199
Approved Standards
•
EN standards certified by TÜV Nord
EN954-1
EN/IEC60204-1
EN/IEC60947-5-3
•
UL508, CSA C22.2 No. 14
•
EN1088 conformance
Internal Connection Diagram
D40B-J1
2
1
A1
13
21
D40B-J2
2
1
A1
+
13
23
31
Control circuit
NC
MOS
output
Control circuit
3
4
A2
X1
X2
14
22
3
4
A2
−
X1
X2
14
24
32
Note: 1.
If a 100/230 VAC power supply is used, connect it to the A1
and A2 terminals. Do not connect the power supply to the +
and
−
terminals.
2.
If a 24 VDC power supply is used, connect it to the + and
−
terminals. Do not connect the power supply to the A1 and
A2 terminals.
!WARNING
Do not connect a 100/230 VAC power supply to the +
and
−
terminals.
Doing so may result in electric shock.
Engineering Data
Detection Ranges
Standard Sensor
Distance between the switch and actuator
sensing surfaces Y (mm)
OFF
14
12
10
8
6
4
ON
2
0
−6
−4
−2
2
0
−6
−4
−2
0
−6
Elongated Sensor
Distance between the switch and actuator
sensing surfaces Y (mm)
OFF
14
12
10
8
6
ON
4
High-temperature Type Sensor
Distance between the switch and actuator
sensing surfaces Y (mm)
25
16
16
20
OFF
15
10
ON
5
0
2
4
6
0
2
4
6
−4
−2
0
2
4
6
Distance from the target mark on the switch X (mm)
Distance from the target mark on the switch X (mm)
Distance from the target mark on the switch X (mm)
G-200
Safety Sensors / Components
Dimensions
Note:
All units are in millimeters unless otherwise indicated.
Sensor (Switch/Actuator)
Standard Sensor
Target mark
Target mark
12
48
48
12
D40B-1B3
D40B-1B10
D40B-1D3
D40B-1D10
4.8
25
4.8
25
13
Two, 4.2 dia.
13
7
22
7
5.5
7.8
Cable diameter: 4.2 dia.
7.8
7
22
Two, 4.2 dia.
7
(Switch)
(Actuator)
Elongated Sensor
D40B-2B3
D40B-2B10
D40B-2D3
D40B-2D10
Target mark
19
4.2
9
Target mark
4.2
19
19
9
4.3
19
9
82
68
54
82
73
64
4.3
9
7
4.5
4.5
10
5
Cable diameter: 4.2 dia.
10
5
5
5
7
(Switch)
(Actuator)
33.5
19.5
4.4
33.5
19.5
16
11.5
8
4.4
11.5
High-temperature Type Sensor
D40B-3D5C
D40B-3E5C
Target mark
Target mark
16
8
62
78.5
62
78.5
11.5
8
11.5
4.4
Note: A cable with connectors is in-
cluded.
11.5
10.5
11
11
10.5
(Switch)
(Actuator)
F3SL
G-201
D40B