FLATPACK RELAY
NF-REL
FEATURES
30.2
1.189
20.0
.787
10.8
.425
1. Flatpack
2. Long seller
mm
inch
SPECIFICATIONS
Contacts
Arrangement
1]
Initial contact resistance
(By voltage drop 6 V DC 1 A)
Contact material
Rating,
(resistive load)
Max.
Typical
Movable contact
Stationary contact
Max. switching power
Max. switching voltage
Max. switching current
Mechanical
Expected life
(min. operations)
1].
Characteristics (at 25°C
77°F,
50% R.H. sea
2 Form C, 4 Form C
50 mOhm
25 mOhm
Gold-clad silver
Gold-clad silver
60 W 100 VA
220 V AC, DC
2A
10
8
2 x 10
5
10
6
10
7
Electrical
(Resistive)
2 A 30 V DC
1 A 30 V DC
0.5 A 30 V DC
MBB types available: 2MBB & 4MBB
(See next page for contact positions.)
Max. operating speed
Initial insulation resistance*
1
Contact/Contact
Electrostatic
Contact/Coil
capacitance
Contact/Ground
Between open contacts
Initial
Between contact sets
breakdown
Between live parts and ground
voltage*
2
Between contacts and coil
Operate time*
3
(at nominal voltage)
Release time (without diode)*
3
(at nominal voltage)
Contact bounce
In de-energized
condition
In energized
condition
Destructive*
5
1,00
Max. 1
Max. 1
Coil
Nominal operating power, at 25∞C
2C
4C
Approx. 300 mW
Approx. 480 mW
Approx. 1 W
at 40°C
104°F
Shock
resistance
Functional*
4
Mi
(In
Mi
(perp
Min
Max. operating power for continuous duty
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as "Initial breakdown voltage" section
*
2
Detection current: 10 mA
*
3
Excluding contact bounce time
*
4
Half-wave pulse of sine wave: 11ms; detection time: 10µs
*
5
Half-wave pulse of sine wave: 6ms
*
6
Detection time: 10µs
*
7
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61).
Vibration
resistance
Functional*
6
In de-energized
condition
In energized
condition
Destructive
Conditions for operation,
Ambient temp.
transport and storage*
7
(Not freezing and condens-
Humidity
ing at low temperature)
2C
Unit weight
4C
Min
29.4 m
at doubl
(in
98 m/
at doubl
(perp
117.6 m
at doub
196 m/
at doub
–
–4
Ap
App
TYPICAL APPLICATIONS
NF relays are widely acceptable in appli-
cations where small size and high sensi-
tivity are required.
Such applications include: Electronic
equipment, Household applications,
198
Alarm systems, Office machines, Com-
munication equipment, Measuring equip-
ment, Remote control systems, General
control circuits, Machine tools, Industrial
machinery, etc.
ORDERING INFORMATION
Ex. NF
4
EB
4M
48V
1
Contact arrangement
2: 2 Form C
4: 4 Form C
Type classification
EB: Standard
MBB function
Nil: Form C type
2M: 2MBB (2 Form D)
4M: 4MBB (4 Form D)
Coil voltage (DC)
5, 6, 12,
24, 48 V
Nil: Gold
1: Gold-c
(Notes) 1. For VDE recognized types, add suffix VDE.
(Notes)
2. For UL/CSA recognized type, add suffix-A, as NF2EB-12V-A whose ground terminal is cut off.
(Notes)
3. Standard packing Carton: 20 pcs.; Case: 200 pcs.
TYPES AND COIL DATA (at 25°C
77°F)
Part No.
NF2EB-5V
NF2EB-6V
NF2EB-12V
NF2EB-24V
NF2EB-48V
NF4EB-5V
NF4EB-6V
NF4EB-12V
NF4EB-24V
NF4EB-48V
Nominal voltage,
V DC
5
6
12
24
48
5
6
12
24
48
Pick-up voltage,
V DC (max.)
4.0
4.8
9.6
19.2
38.4
4.0
4.8
9.6
19.2
38.4
Drop-out
voltage,
V DC (min.)
0.5
0.6
1.2
2.4
4.8
0.5
0.6
1.2
2.4
4.8
Max. allowable
voltage,
V DC (at 40°C)
8.7
10.5
21
42
84
7
8.5
17.0
34
68
Coil resistance,*
Ohm
90
137
500
2,000
7,000
53
90
330
1,200
4,200
Nom
operatin
m
27
26
29
29
33
47
40
44
48
55
DIMENSIONS
2 Form C
10.8±0.3
.425±.012
0.3
.012
30.2
1.189
20.6
.811
PC board pa
Schematic
4.9
.193
5.1±0.2
.2±.008
4.9
.193
Relay
outline
6 3
4-0.8 dia.
.031 dia.
Stand-off
1.13
.044
8 5
Resin rise
max. 0.5
max.
.020
3.3
.130
N.O. N.C.
Ground terminal
13 20
.512 .787
7 4
2
Common terminal
Coil terminal
Terminal dimensions (except soldering)
Width: 0.8
.031
Thickness: 0.3
.012
MBB contact position
NF2-2M: terminal 6-7-8, 3-4-5
4 Form C
10.8±0.3
.425±.012
0.3
.012
30.2
1.189
20.6
.811
1
PC board pa
Schematic
2.1
.083
5
4
3
1.13
.044
4-0.8 dia.
.031 dia.
Stand-off
1
11 8
13.6 24.6
.535 .969
10 7
9 6
14
13
12
Resin rise
max. 0.5
max.
.020
3.3
.130
N.O. N.C.
Ground terminal
2
5.1±0.2
.2±.008
Common terminal
Coil terminal
2.1
.083
Terminal dimensions (except soldering)
Width: 0.8
.031
Thickness: 0.3
.012
MBB contact position
NF4-2M: terminals 6-7-8, 9-10-11
NF4-2M: terminals 6-7-8, 3-4-5, 12-13-14, 9-10-11
Relay
outline
General tolerance:
±0.5
±.020
(Except for the cover height)
NF
REFERENCE DATA
1. Life curve
2. Coil temperature rise (resistance method)
3. H
2
S gas test
100Ω
Coil temperature rise,
°C
No. of operations,
×10
4
50Ω
60
Contact resistance
0.2 0.4 0.6 0.8 1.0 1.2 1.4
Operating power, W
10Ω
5Ω
1Ω
1,000
100
30 V DC Resistive
40
500mΩ
20
100mΩ
50mΩ
10
0.5
1
1.5
2
2.5
Load current, A
20 50 100 200 1,0
500
Expo
4. Contact reliability
Test conditions:
1. Contact current/voltage: 10
µA
100 mV 1 kHz
2. Cycle rate 20 cps.
3. Miscontact detection level: 1 mW (= 100
Ohm)
4. Detection method: Observation of all changeover
contacts
5. High temperature test
Test conditions:
Ambient temperature: 80°C
±2°C
Test method:
1. All contacts were switched for 100 operations on 2
A 30 V DC resistive load.
2. Samples then were exposed to 80°C temperature
for 5,000 hours, continuous
3. Contact resistance was measured with Hewlett-
Packard testing equipment.
70
Contact resistance, mΩ
60
50
40
N.C. contacts
30
20
10
N.O. contacts
Max.
Min.
Max.
Min.
Test result:
Amber relays showed a stable
tance within the initially speci
hours exposure.
F(t)(%)
99.9
99.0
95.0
90.0
80.0
60.0 70.0
50.0
40.0
30.0
25.0
20.0
15.0
10.0
5.0
4.0
3.0
2.0
1.5
1.0
0.5
0.4
0.3
0.2
0.15
0.1
0.1
0.5 1.0
5.0 10.0
50 100
No. of operations,
×10
6
0
100 200 300 400 500 1,000
5,000
3,000
Exposure, hrs.
Test result:
m = 1.5
m
= 21.2 x 10
6
95% confidence level = 3.1
x
10
6
17 contacts out of 20 achieved 10 million no miscon-
tact operations.
NOTES
1. Prevention of vibration and shock
To reduce the likelihood of vibration and
shock, we recommend that you install so
that the contact action is not in the direc-
tion of gravity.
Top
Common terminal
Coil terminal
NC terminal
NO terminal
Bottom
200
2001 Matsushita Electric Works Group Europe
For Cautions for Use, see Relay Technical Information.