15W DC-DC Converter P15D-Series
●
●
●
●
●
●
Efficiency up to 92 %
Wide 2:1 input range
1500 V
DC
isolation
Continuous short circuit protection
Five – sided continuous shield
Standard package 2” x 1” x 0.4”
Model selection guide
Typ
Single output
P15D123R3S
P15D1205S
P15D127R2S
P15D1209S
P15D1212S
P15D1215S
P15D1218S
P15D1224S
P15D243R3S
P15D2405S
P15D247R2S
P15D2409S
P15D2412S
P15D2415S
P15D2418S
P15D2424S
P15D483R3S
P15D4805S
P15D487R2S
P15D4809S
P15D4812S
P15D4815S
P15D4818S
P15D4824S
Dual output
P15D123R3D
P15D1205D
P15D127R2D
P15D1209D
P15D1212D
P15D1215D
P15D1218D
P15D1224D
P15D243R3D
P15D2405D
P15D247R2D
P15D2409D
P15D2412D
P15D2415D
P15D2418D
P15D2424D
P15D483R3D
P15D4805D
P15D487R2D
P15D4809D
P15D4812D
P15D4815D
P15D4818D
P15D4824D
Input nominal voltage
[V
DC
]
9...18
9...18
9...18
9...18
9...18
9...18
9...18
9...18
18...36
18...36
18...36
18...36
18...36
18...36
18...36
18...36
36...72
36...72
36...72
36...72
36...72
36...72
36...72
36...72
9...18
9...18
9...18
9...18
9...18
9...18
9...18
9...18
18...36
18...36
18...36
18...36
18...36
18...36
18...36
18...36
36...72
36...72
36...72
36...72
36...72
36...72
36...72
36...72
Output voltage
[V
DC
]
3.3
5.0
7.2
9.0
12.0
15.0
18.0
24.0
3.3
5.0
7.2
9.0
12.0
15.0
18.0
24.0
3.3
5.0
7.2
9.0
12.0
15.0
18.0
24.0
±3.3
±5.0
±7.2
±9.0
±12.0
±15.0
±18.0
±24.0
±3.3
±5.0
±7.2
±9.0
±12.0
±15.0
±18.0
±24.0
±3.3
±5.0
±7.2
±9.0
±12.0
±15.0
±18.0
±24.0
Output current
[mA]
3000
3000
2083
1667
1250
1000
833
625
3000
3000
2083
1667
1250
1000
833
625
3000
3000
2083
1667
1250
1000
833
625
±1500
±1500
±1042
±833
±625
±500
±417
±312
±1500
±1500
±1042
±833
±625
±500
±417
±312
±1500
±1500
±1042
±833
±625
±500
±417
±312
Efficiency typ.
[%]
83
83
83
84
85
85
86
86
84
85
86
87
88
88
89
90
85
86
86
87
89
89
90
92
83
83
83
84
85
85
86
86
83
85
86
87
88
88
89
90
84
86
86
87
89
89
89
90
Page 1 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: power@hy-line.de
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: power@hy-line.ch
15W DC-DC Converter P15D-Series
Specifications
Input
Voltage range
Filter
Isolation:
Rated voltage
Resistance
Capacitance
Output
Voltage accuracy
Voltage balance
(dual outputs)
Ripple and noise
(at 20 MHz BW)
Short circuit protection
Over load protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
12 V
DC
, 9…18 V
DC
24 V
DC
, 18…36 V
DC
48 V
DC
, 36…72 V
DC
Capacitors
1500 V
DC
9
10
Ω
500 pF, typ.
± 1%, max
± 1%
100 mVp-p, max
Continuous
130 %, typ.
Automatic
± 0.5%, max.
± 0.5%, max.
± 0.02% / °C
General
Efficiency
Switching frequency
Environmental
Operating temperatur
(ambient)
Case temperature
Storage temperature
Derating
Humidity
Cooling
Physical
Dimensions
Weight
Case material
83..92 %
200 kHz, typ.
-40 °C to +85 °C
100 °C, max.
-40 °C to +125 °C
None required
Up to 90%,
non-condensing
Free-air convection
50.80 x 25.40 x 10.16 mm
46.0 g
Nickel-coated copper metal
Dimensions
Common
Bottom view
Stand offs
All dimensions in mm (inches)
Tolerance ±0.25 mm (±0.01)
Output ripple and noise reduction
+
DC Power
Source
-
+input
+output
Scope
Load
To reduce ripple and noise, it is recommended to use
1µF ceramic and a 10µF electrolytic capacitors to the
output
DC/DC -
Converter
-input
-output
Life Support Policy:
HY-LINE does not authorize the use of any of its products for use in life support devices or systems
without the express written approval of an officer of the Company. Life support systems are devices which support or
sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the
labeling, can be reasonably expected to result in significant injury to the user.
Rev: 6 / 05f
Page 2 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: power@hy-line.de
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: power@hy-line.ch