EEWORLDEEWORLDEEWORLD

Part Number

Search

CT 0.1-P

Description
transducer current 0.2A 15v
CategoryThe sensor   
File Size928KB,3 Pages
ManufacturerLEM
Websitehttp://www.lem.com
Environmental Compliance  
Download Datasheet Compare View All

CT 0.1-P Overview

transducer current 0.2A 15v

Current Transducers CT 0.1 .. 0.4-P
For the electronic measurement of small currents: AC,DC, mixed,
with a galvanic isolation between the primary circuit and the
secondary circuit.
I
PN
= ± 100..400 mA
V
OUT
= ± 5 V
Electrical data
Primary nominal
current rms
I
PN
(mA)
100
200
400
Primary current,
measuring range
I
PM
(mA)
± 200
± 400
± 800
Type
RoHS since
date code
46129
46054
46234
Features
DC & AC earth leakage current
transducer using a flux-gate
principle
PCB mounting
±
15V power supply
±
5V output
@
I
PN
Isolated plastic case recognized
according to UL94-V0.
CT 0.1-P
CT 0.2-P
CT 0.4-P
V
C
I
C
R
IS
V
OUT
R
OUT
R
L
C
L
Supply voltage (± 5 %)
Current consumption
Isolation resistance @ 500 VDC
Output voltage (Analog) @ ±
I
PN,
R
L
= 10kΩ
,
T
A
=25°C
Output internal resistance
Load resistance
Capacitive loading
± 15
± 45
> 500
±5
< 51
10
5
V
mA
MΩ
V
kΩ
nF
Accuracy-Dynamic performance data
X
Advantages
<±1
%of
I
PN
< ± 0.5 %of
I
PN
< ± 0.05 %/K
< ± 100
mV
<±2
mV
< ± 20
mV
<±8
mV/K
<±4
mV/K
<±2
mV/K
20
ms
60
ms
DC 40..7000Hz
DC 40..11000Hz
DC 40..18000Hz
TCV
OUT
V
OE
V
OH
ε
L
TCV
OE
t
r
BW
Accuracy (excluding offset) @
I
PN,
T
A
= 25°C,
R
L
= 10kΩ
Linearity error (0 .. ±
I
PN
)
Temperature coefficient of
V
OUT
(of reading)
Electrical offset voltage @
I
P
= 0,
T
A
= 25°C
Hysteresis offset voltage
@
I
P
= 0; after an excursion of 1 x
I
PN
@
I
P
= 0; after an excursion of 100 x
I
PN
Temperature coefficient of
V
OE
@ -20..+85°C CT 0.1-P
CT 0.2-P
CT 0.4-P
Response time to 80% of
I
PN
step
90% of
I
PN
step
Frequency bandwidth (- 3 dB)
CT 0.1-P
CT 0.2-P
CT 0.4-P
Small size
Bandwidth :
DC and 40 up to 7..18 kHz
Response time better than 60 ms
Cost effective, compact
alternative to classical RCDs
(Residual Current Device)
Applications
Earth leakage detection in
transformerless solar inverters
1st human contact protection of
PV arrays
Failure detection in power sources
Symmetrical fault detection
(e.g. after motor inverter)
Current leakage detection in
stacked DC sources
Single phase or three phase
differential current measurement up
to
±
30A per wire (DC or AC)
General data
T
A
T
S
dCp
dCl
CTI
m
Ambient operating temperature
Ambient storage temperature
Creepage distance
Clearance distance
Comparative tracking index (Group IIIa)
Mass
Standards
- 20 .. + 85 °C
- 25 .. + 85 °C
> 5.5
mm
> 5.5
mm
> 220
25
g
EN 50178: 1997
Notes : Performance data are given for steady phase of the transducer.
Transitory period after power on lasts typically less than 2 min.
Please refer to characterization report for details.
Please don't put the high voltage between the secondary pins and fixing
pins. If it must be so, don't exceed the 2.5 kV between these pins with the
maximum isolation distance.
080909/14
Application domain
Industrial
copyright protected
Page 1/3
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com

CT 0.1-P Related Products

CT 0.1-P CT 0.4-P CT 0.2-P
Description transducer current 0.2A 15v sensor curr 400ma -/+15v mod transducer current 0.2A 15v

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号