Embedded Power for
Business-Critical Continuity
AIF - PFC Series
1600 Watts
Total Power:
1600 Watts
/120 - 370VDC
(Configurable)
Input Voltage: 85 - 264VAC
# of Outputs:
Single
Rev. 09.07.10
AIF-PFC Series
1 of 2
Electrical Specifications
Special Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Unity power factor
High efficiency - up to 95%
Universal input voltage
and frequency range
Up to 1600W output power
Positive and Negative
enable function
Parallelable with accurate
current sharing
<10% harmonic distortion
conforming to IEC1000-3-2
Compliance
100°C baseplate operating
temperature
DC Input option
Power fail warning signal
Enable output to control
DC-DC Converter
EEPROM data storage via
I2C Interface
External inrush current
limited protection
Power Density up to 290W/in
3
Input
Input ra nge
Input surge
Input Frequency
Efficiency
Total Harmonic Distortion
Power Factor
85 - 264 Vac / 120 - 370 Vdc (configurable)
290 Vac / 1s
50/60 Hz
95% @ 230Vac, 1600 W (typical)
Less than 10%
0.99 typical (Po ± 500 W); 0.97 typical (Po ± 1000 W)
380V typical(Io =4.2A / Vi > 180 Vac); 393V typical (Io = 0A)
Note: Vin peak must always be lower than Vout
10% max
430 max
Vin = 85Vac, Pmax = 1000W; Vin = 230Vac, Pmax = 1600W
Vin = 370Vdc, Pmax =1600W
Direct drive output to opto-isolator
195 to 355Vdc adjustable
Direct drive output to opto-isolator
TTL compatiable
76% to 100% Vo
6Vp-p typical @ 1MHz ± 5%
6Vp-p typical @ 1MHz ± 5%
10mV/°C
0 to 1mA (1mA = 4.2A output)
Output
Output Voltage
Current Share Accuracy
Overvoltage Protection
Power Limit for AC input
for DC input
Control
Power Fail Warning
Power Fail Warning Adjust
LD Enable
PFC Enable
Voltage Adjust
DC Input Enable
Clock Input (external sync)
Clock Output (int. clock)
Temperature Monitor Output
Current Monitor Output
I
2
C Interface
Safety
UL
cUL
TUV
60950 Recognized
60950 Recognized
EN60950
Licensed
Notes
Nominal values apply with sense pins disconnected and other control pin unconnected.
Embedded Power for
Business-Critical Continuity
Environmental Specifications
Operating temperature
Startup temperature
-20°C to +100°C (baseplate temperature)
-40°C to +100°C (baseplate temperature)
Storage temperature
-40°C to +120°C
Overtemperature protection 120°C max
MTBF
1million hours
Americas
Rev. 09.07.10
AIF-PFC Series
2 of 2
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Europe (UK)
Ordering Information
Model Number
AIF04ZPFC-01L
AIF04ZPFC-02L
AIF04ZPFC-01NL
AIF04ZPFC-01NL
Description
1600W Low Profile PC Module
Notes
For parallel operation the total input current must be
<16Arms.
Designed for parallel operation where the total input
1600W Low Profile PC Module
current >16Arms, requires external rail rectifiers.
Negative Enable
Negative Enable
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
1. Fon Non-thread hole, add suffix “-NT”.
Pin Assignments
Mechanical Drawing
Input (AC) Output (DC)
31. L1
32. L1
33. L2
34. L2
21. Positive
22. Positive
23. Negative
24. Negative
Control
Pins
1. PV Aux -
2. Temp Mon
3. C Mon
4. C Share
5. Clk Out
6. Clk In
7. PV Aux +
8. SDA
9. SCL
10. DC Enable
11. V Adj
12. PFW Adj
13. S Gnd
14. PFW
15. LD Enable
16. PF Enable
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.Emerson.com/EmbeddedPower
techsupport.embeddedpower
@emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower.com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2010 Emerson Electric Co.
Specifications subject to change without notice.