Technical Reference Note
AIF - PFC Power Factor
Correction Series
AIF - PFC 1600W AC-DC Converter Module
The PFC Power Factor Correction module is part of Astec’s family of advanced High Density modular power supply
components. Featuring high reliability and convenient control and monitoring functions, these modules are designed to
reduce product development time and enhance system performance. The PFC is designed to work over all typical line
voltages used worldwide, and provide unity power factor with very low levels of harmonic distortion in line current. The PFC
includes active start-up current control. Power Line Disturbance (PLD) circuitry copes with a wide range of input voltage
fluctuations..
Electrical Parameters
Input
85 – 264 VAC
120 - 370VDC (Configurable)
Input Surge
290Vac / 1s
Efficiency
95%@ 230Vac, 1600W (Typical)
Total Harmonic 10%
Distortion
Control
Enable TTL compatible
(Positive & negative enable options)
Input range
Special Features
•
•
•
•
•
•
•
•
•
•
•
•
•
Switching Frequency 125KHz
Unity Power Factor
DC input (Configurable)
High Efficiency - up to 95%
Universal input voltage and frequency range
Up to 1600W output power
Parallelable with current sharing within 10%
< 10% harmonic distortion conforming to IEC 1000-
3-2 Compliance
100°C baseplate operating temperature.
High Reliability - over 1 million hours MTBF
@ baseplate temperature 50°C
Programmable Power Fail Warning Signal
EEPROM data storage via I
2
C interface
Power Density up to 290W/in
3
Output
Output Voltage
Io =4.2A / Vi > 180Vac
Io = 0
380V typ
393V typ
Maximum output Power
85Vac
≤
Vin
≤
120Vac 1000W
120Vac < Vin < 220Vac See P. 16
Vin
≥
220Vac
1600W
Output voltage
Adjust range
76% - 100% of nominal
output
Overvoltage Protection 430V
Environmental Specifications
•
•
•
Operating temperature: -20°C to +100°C
(baseplate)
Storage temperature: -40°C to +110°C
Meet power line disturbance immunity
specification per IEC 61000-4-11
“ Generic Immunity Standards against
voltage dips, interruptions”
Safety
UL, cUL
TUV
60950 Recognized
EN60950 Licensed
MODEL : AIF -
PFC SERIES
December, 2004 REVISION 07
SH 1 of 30
Technical Reference Note
AIF - PFC Power Factor
Correction Series
AIF - PFC SERIES
THIS SPECIFICATION COVERS THE REQUIREMENTS
FOR A New Full Brick 1600W AC/DC Converter
MODEL NAME
AIF04ZPFC-01
AIF04ZPFC-01N
AIF04ZPFC-02
AIF04ZPFC-02N
AIF04ZPFC-01NT
AIF04ZPFC-01NNT
AIF04ZPFC-02NT
AIF04ZPFC-02NNT
* 1600W max
SIS CODE
AIF04ZPFC-01
AIF04ZPFC-01N
AIF04ZPFC-02
AIF04ZPFC-02N
AIF04ZPFC-01NT
AIF04ZPFC-01NNT
AIF04ZPFC-02NT
AIF04ZPFC-02NNT
Vout,Iout
380V, 4.2A
380V, 4.2A
380V, 4.2A
380V, 4.2A
380V, 4.2A
380V, 4.2A
380V, 4.2A
380V, 4.2A
SERIAL NO.
PREFIX
A648
B796
A826
B797
D943
D945
D944
D946
Suffix
N
No Suffix
NT
Option
Negative Logic Enable
Positive Logic Enable
Non-thread hole
MODEL : AIF -
PFC Series
December, 2004 REVISION 07
SH
2 of 30
Technical Reference Note
AIF - PFC Power Factor
Correction Series
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage and temperature conditions.
Standard test condition on a single unit.
Tambient:
L1:
L2:
Enable:
+Vout1:
−Vout1:
Trim(Vadj):
Output Cap:
25°C
115Vac, 220Vac
return pin for L1
Open
connect to load
connect to load (return)
connect to S GND
470uF x 2
ABSOLUTE MAXIMUM RATINGS
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute
stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of
those given in the operational sections of the specs. Exposure to absolute maximum ratings for extended periods can
adversely affect device reliability.
Parameter
Input Voltage:
Continuous:
Surge Voltage (1 sec)
Operating Case Temperature
Start up Case Temperature
Storage Temperature
Operating Humidity
Isolation
Input to Baseplate
Output to Baseplate
Baseplate Capacitance
Device
Symbol
Min
Typ
Max
Unit
All
All
All
All
All
All
V
I
V
I
Tc
85
-
264
290
100
100
Vac
Vac
ºC
ºC
ºC
%
-20
-40
-
T
STG
-
-40
-
-
-
110
95
All
-
-
-
-
-
-
-
-
2700
2700
1300
Vdc
Vdc
PF
MODEL : AIF -
PFC Series
December, 2004 REVISION 07
SH
3 of 30
Technical Reference Note
AIF - PFC Power Factor
Correction Series
CONTROL SIGNALS
Control Function
TEMP MON - temperature
monitor signal
V ADJ - voltage adjust
C MON - current monitor
signal
C SHARE - current share
function**
CLK OUT - clock output
Conditions
Parameter
V
TEMP MON
Sensitivity
Source impedence
Vo
I
C MON
I
O
/I
C MON
C SHARE accuracy
Max no. of units
V
CLK OUT
Clock freq.
Max fan out
VCLK IN
Clock freq
PFW set point
PFW set point
PFW set point
PFW ADJ current source
V
PFW
V
PFW
PFW current source
V
LD ENABLE
V
LD ENABLE
LD ENABLE current source
V
PF ENABLE
V
PF ENABLE
V
PF ENABLE
V
PF ENABLE
PF ENABLE current source
PV_AUX Voltage
PV_AUX Voltage
Min
9.8
76
0.9
Typ
10
16
1
4.2
±3%
5
1
Max
10.2
100
1.1
±10
10
1.03
2
6
1.05
295
335
355
15
0.4
-
15
0.4
-
0.8
5
5
0.8
400
8
11
9
Units
mV/°C
KΩ
% VO
nom
mA
A/mA
%IO
rated
Vp-p
MHz
Vp-p
MHz
VDC
VDC
VDC
mA
V
V
mA
V
V
mA
V
V
V
V
µA
V
V
Adjust using external resistor
IO = 4.2A
IO = 20 to 100% IOrated
C SHARE pins of modules in
parallel connected
CLK IN open
0.97
4.5
0.95
265
305
325
12
0
–
12
0
–
0
2.2
2.2
0
CLK IN - clock input
PFW ADJ - power fail
warning adjust
PFW ADJ=0 to 2.80 VDC
PFW ADJ=3.2 VDC
PFW ADJ = 3.40VDC
Input Power OK, I
PFW
= 0
Input Power Fail, I
PFW
= 15mA
(PFW short to S_GND)
Load enabled, (I
LD ENABLE
= 0)
Load disabled, (I
LD ENABLE
= 15mA)
LD ENABLE short to S_GND
Negative Enable:
Module enabled
Module disabled
Positive Enable:
Module enabled
Module disabled
V
ENABLE
= 0.8V
I
PV_AUX
= 0A
I
PV_AUX
= 20mA
PFW - power fail warning***
LD ENABLE - load enable
1
280
320
340
1
13.7
0.2
2.9
13.7
0.2
2.9
PF ENABLE - module
enable***
PV_AUX***
** For AIF04ZPFC-01, total input current of all the modules must not exceed 16A rms
*** Only apply on primary side
MODEL : AIF -
PFC Series
December, 2004 REVISION 07
SH
4 of 30
Technical Reference Note
AIF - PFC Power Factor
Correction Series
INPUT SPECIFICATIONS
Parameter
Operating Input Voltage
Input Current
(V
I
= 115Vac, Load = 1000W)
Inrush Transient
(Need external inrush limiting
circuit)
Power Factor
No Load Input Power
(V
I
= V
I,nom
)
Total Harmonic Distortion
(IEC1000-3-2)
Note:
1)
2)
3)
4)
5)
6)
Half cycle surge current due to input transient surge must be limited to 20A peak or less
Need external inrush limiting circuit
For AIF04ZPFC-01, total input current for modules connected in parallel must not exceed 16A
For AIF04ZPFC-02, negative rail input rectifiers must be provided by external circuitry. See P.24
Total harmonic distortion – input harmonics meet the requirements of IEC 1000-3-2
The PFC’s LD ENABLE signal is recommended to be used to enable the load in case of initial surge load condition
Device
All
Symbol
V
I
I
I,max
Min
85
-
Typ
Max
264
Unit
V
AC
A
-
10
-
20
Apk
Po
≥
500W
Po
≥
1000W
All
-
0.96
0.98
-
0.97
0.99
-
3.8
W
All
-
-
-
10
%
MODEL : AIF -
PFC Series
December, 2004 REVISION 07
SH