IP Rating ............................................................ IP 40 .....................................................................IP 40
*RoHS Directive 2002/95/EC Jan 27 2003 including Annex
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
Model 91, 92, 93, 94 & 95 - 5/8 ” Square Single-Turn Panel Control
Mechanical Characteristics
1
Stop Strength (1/4 ” D shaft) .............................................................................................................................................45.19 N-cm (4 lb.-in.)
(1/8 ” D shaft) .............................................................................................................................................33.89 N-cm (3 lb.-in.)
Starting ........................................................................................................................................... 0.3 max. above average running torque
Running Torque
Single or Dual Section (A & R Bushings) .................................................................................................. 0.21 to 1.06 N-cm (0.3 to 1.5 oz.-in.)
Single or Dual Section (C & U Bushings) .................................................................................................. 0.14 to 1.06 N-cm (0.2 to 1.5 oz.-in.)
Mounting .............................................................................................................................................1.7-2.0 N-m (15-18 lb.-in.) maximum
Variation ...................................................................................................................... 0.35 N-cm (0.5 oz.-in.) maximum in 45 ° shaft travel
Weight (Single Section, Metal Bushing)...............................................................................................................................12.7 grams nominal
Terminals .................................................................................................................................Printed circuit terminals, J-Hooks or solder lugs
Soldering Condition ...........................................Recommended hand soldering using Sn95/Ag5 no clean solder, 0.025 ” wire diameter.
Maximum temperature 399 °C (750 °F) for 3 seconds. No wash process to be used with no clean flux.
Marking ..................................................................................Manufacturer’s trademark, date code, resistance, manufacturer’s part number
Ganging (Multiple Section Potentiometers).............................................................................................................................2 cups maximum
Hardware ...................One lockwasher and one mounting nut is shipped with each potentiometer, except where noted in the part number.
NOTE:
1
At
Performance specifications do not apply to units subjected to printed circuit board cleaning procedures.
room ambient: +25 °C nominal and 50 % relative humidity nominal, except as noted.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
Model 91, 92, 93, 94 & 95 - 5/8 ” Square Single-Turn Panel Control
Product Dimensions
Model 91 PC Pin Terminals, In-Line
22.86 ± 0.43
(.900 ± .017)
MOUNTING
SURFACE
12.70 ± .229
(.500 ± .009)
0.79 ± .025
(.031 ± .010)
DIA.
13.72 ± 0.38
(.540 ± .015)
1.37 ± 0.08
(.054 ± .003)
2.36 ± 0.08
(.093 ± .003)
15.88
(.625)
7.92
(.312)
Model 92 J-Hooked
Terminals, In-Line
.79
(.031) 2 PLCS.
3 2 1
SEE
HOW TO ORDER
CHART FOR
BUSHING OPTIONS.
10.16 ± 0.30
(.400 ± .012)
11.05 ± 0.20
(.435 ± .008)
SEE
NEXT PAGE
FOR SHAFT
OPTIONS.
2.54
(.100)
2.54
(.100)
1.19
(.047)
“A” STYLE
A.R. LUG
R
9.53
(.375)
15.29 ± 0.56
(.602 ± .022)
.254
(.010)
GAP
5.08
(.20)
1.52
(.06)
R2
R1
1
2
3
1
2
3
0.76 ± 0.05
(.030 ± .002)
TYP.
Model 94 J-Hooked
Terminals, "L" Pattern
Model 93 PC Pin Terminals, "L" Pattern
22.86 ± 0.43
(.900 ± .017)
MOUNTING
SURFACE
12.70 ± .229
(.500 ± .009)
0.79 ± .025
(.031 ± .010)
DIA.
13.72 ± 0.38
(.540 ± .015)
1.37 ± 0.08
(.054 ± .003)
2.36 ± 0.08
(.093 ± .003)
15.88
(.625)
7.92
(.312)
.81
(.032)
R. MAX.
5.33 ± .76
(.21 ± .03)
3.81
(.150)
MAX. TYP.
1.52
(.06)
GAP
3 2 1
SEE
HOW TO ORDER
CHART FOR
BUSHING OPTIONS.
DIA.
0.81
TYP.
(.032)
10.16 ± 0.30
(.400 ± .012)
R2
R1
5.08 ± 0.38
(.200 ± .015)
11.05 ± 0.20
(.435 ± .008)
SEE
NEXT PAGE
FOR SHAFT
OPTIONS.
1.19
(.047)
“A” STYLE
A.R. LUG
R
9.53
(.375)
12.70 ± 1.02
(.500 ± .040)
Shaft Flat Orientation
2.54
(.100)
2.54
(.100)
1
3
2
1
3
2
0.76 ± 0.05
(.030 ± .002)
TYP.
120 ° ± 5 ° STD.
FLAT ORIENTATION
(SHAFT AT CCW END)
1
CCW
2
POTENTIOMETER
3
Model 95 Solder Lug Terminals, "Triangular" Pattern
[color=#000000][backcolor=white]Transient response describes the ability of DCDC to respond to rapidly changing loads. For CPU core voltage or RF power amplifier circuit, transient response is a very ...
As the title says, why do we need to add an inductor between VBAT and VDDA as shown in the figure below, and what should the value of this inductor be?...
Electromagnetic pulse (EMP) is a physical phenomenon. It is mainly used to destroy enemy electronic equipment. The longest duration of an electromagnetic pulse is usually only one second. It is a sudd...