BURNDY
Compression
TWO HOLE HYLUG™
CODE CONDUCTOR
LONG BARREL
TYPES YA-2N, YA-2TC,
YA-4N
UL LISTED 90° C,
600 VOLT TO 35 KV
x
ELECTRO-TIN
PLATED
CABLE
ACCOMMODATION
DIE AND COLOR
CODE INFORMATION
BEVELED
ENTRY
NO INSPECTION
WINDOW
CRIMP
C-48
B
B
90°
T
45°
B
T
L
T
L
L
Fig. 1
Fig. 2
Fig. 3
Conductor
Catalog Number
YA8C2TC14
YA8C2TC14-45
YA8C2TC14-90
YA8C2TC14E2
YA8C2TC14E2-45
YA8C2TC14E2-90
YA8C2TC38
YA8C2TC38-45
YA8C2TC38-90
YA6C2N
YA6C2N-45
YA6C2N-90
YA6C2TC14
YA6C2TC14-45
YA6C2TC14-90
YA6C2TC14E1
YA6C2TC14E1-45
YA6C2TC14E1-90
YA6C2TC14E2
YA6C2TC14E2-45
YA6C2TC14E2-90
YA6C2TC38
YA6C2TC38-45
YA6C2TC38-90
YA6C2TC38E2
YA6C2TC38E2-45
YA6C2TC38E2-90
YA6C2TC38E6
YA6C2TC38E6-45
YA6C2TC38E6-90
Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
AWG
***
MM
2
Stud Stud
Hole Hole Tongue
Size Spacing Width
.40
1/4
5/8
.40
.41
.41
1/4
3/4
.41
.41
.73
3/8
1
.73
.73
.81
1/2 1-3/4 .81
.81
.45
1/4
5/8
.45
.45
.45
1/4
1
.45
.45
.45
1/4
3/4
.45
.45
.63
3/8
1
.63
.63
.63
3/8
3/4
.63
.63
.63
3/8
7/8
.63
.63
Figure
Dimensions
(B) (T)
(L)
2.33
.81 .08 2.20
1.49
2.45
.81 .08 2.33
1.62
2.89
.81 .06 2.72
2.05
4.40
1.12 .12 4.29
3.28
2.65
1.12 .08 2.45
1.51
3.03
1.12 .08 2.83
1.88
2.78
1.12 .08 2.58
1.63
3.22
1.12 .06 2.97
2.06
2.97
1.12 .06 2.72
1.81
2.99
1.12 .06 2.75
1.83
Dieless
(# of crimps)
Mechanical
MD6, OUR840
MD7-34R
v
Installation Tooling
Hydraulic
Wire
BCT500HS
Y35,Y39,Y750 Color Die Strip
Y500CTHS Y46, BAT35, BAT750 Code Index Length
#8 STR.
†
#6 SOL
10
37/24
Y2MR (2)
Y8MRB-1 (2) W8CVT (2)
MY29-3 (2) W8CRT (2)
MY29-11 (2) X8CRT (2)
MRC840 (2)
W8CVT (2)
W8CRT (2)
X8CRT (2)
U8CRT (1)
Red
49
1
#6 AWG
-
Y1MR (2)
W5CVT (2) W5CVT (2)
Y2MR (2)
W5CRT (2) W5CRT (2)
MY29-3 (2)
X5CRT (2) X5CRT (2)
MY29-11 (2)
X8CART (2) X8CART (2)
MRC840 (2)
U5CRT (2)
U8CABT (2)
Blue
7
1-3/16
v
See tooling section of this catalog for complete tool and die listings.
* Use P-UADP-1 adaptor with "U" -dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, P-UADP-1 adapter not required.
*** The MM
2
conductor sizes listed are the recommendations for Class 2 conductor.
† The MM
2
conductor size listed here is for Class 2 and Class 5 conductor.
" Available undrilled. Add suffix "U" to catalog number (example: YA25U).
x
For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions.
BURNDY
Compression
TWO HOLE HYLUG™
CODE CONDUCTOR
LONG BARREL
(CONTINUED)
Conductor
Catalog Number
YA5C2N
YA5C2N-45
YA5C2N-90
YA4C2N
YA4C2N-45
YA4C2N-90
YA4C2TC14
YA4C2TC14-45
YA4C2TC14-90
YA4C2TC14E2
YA4C2TC14E2-45
YA4C2TC14E2-90
YA4C2TC38
YA4C2TC38-45
YA4C2TC38-90
YA3C2N
YA3C2N-45
YA3C2N-90
YA3C2TC14
YA3C2TC14-45
YA3C2TC14-90
YA3C2TC14E2
YA3C2TC14E2-45
YA3C2TC14E2-90
YA3C2TC38
YA3C2TC38-45
YA3C2TC38-90
YA3C2TC38E2
YA3C2TC38E2-45
YA3C2TC38E2-90
YA2C2N
YA2C2N-45
YA2C2N-90
YA2C2TC14
YA2C2TC14-45
YA2C2TC14-90
YA2C2TC14E2
YA2C2TC14E2-45
YA2C2TC14E2-90
YA2C2TC38E2
YA2C2TC38E2-45
YA2C2TC38E2-90
YA2C2TC516E2
YA2C2TC516E2-45
YA2C2TC516E2-90
YA2C2NTC38
YA2C2NTC38-45
YA2C2NTC38-90
Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
AWG
5 AWG
***
MM
2
-
Stud Stud
Hole Hole Tongue
Size Spacing Width
1/2
1-3/4
.83
Figure
Dimensions
(B) (T)
(L)
4.43
1.12 .12 4.31
3.28
4.45
4.32
3.30
2.70
2.51
1.54
2.83
2.64
1.66
3.26
3.03
2.09
4.62
4.44
3.32
2.87
2.62
1.55
2.99
2.75
1.68
3.43
3.16
2.11
3.18
2.91
1.86
4.64
4.46
3.34
2.86
2.66
1.58
2.98
2.78
1.71
3.17
2.97
1.90
3.05
2.84
1.77
4.17
3.97
2.90
Dieless
(# of crimps)
B
B
90°
T
45°
B
T
L
T
L
L
Fig. 1
Fig. 2
Mechanical
MD6, OUR840
MD7-34R
W5CRT (2)
W5CVT (2)
X5CRT (2)
Fig. 3
v
Installation Tooling
Hydraulic
Wire
BCT500HS
Y35,Y39,Y750 Color Die Strip
Y500CTHS Y46, BAT35, BAT750 Code Index Length
X5CRT (2)
X5CVT (2)
W5CRT (2)
C-49
U5CRT (2)
Blue
7
1-3/16
MY29-3 (2)
MY29-1 (2)
MRC840 (2)
Y644M (1)
1/2
1-3/4
.81
1.12 .12
1/4
4 AWG
-
1/4
5/8
.50
1.12 .09
3/4
.50
.
.56
1.12 .09
W4CVT (2)
W4CRT (2)
X4CRT (2)
W4CVT (2)
W4CRT (2)
X4CRT (2)
U4CRT (2)
U6CABT (2)
Gray
8
1-3/16
3/8
1
1.12 .08
1/2
1-3/4
.81
1.25 .12
1/4
#3 STR
# 3 AWG
#2 SOL
3/8
25
1/4
5/8
.55
1.25 .09
3/4
.55
1.25 .09
1
.58
1.25 .08
Y1MR (4)
Y2MR (4)
MY29-3 (2)
MY29-11 (2)
MRC840 (2)
Y644M (1)
W3CRT (2)
W3CRT (2)
U3CRT (2)
White
9
1-5/16
3/8
3/4
.58
1.25 .08
1/2
1-3/4
.81
1.25 .12
1/4
5/8
.60
1.25 .11
1/4
#2 AWG
35
3/8
3/4
.60
1.25 .11
W2CVT (2)
W2CRT (2)
X2CRT (2)
W2CVT (2)
W2CRT (2)
X2CRT (2)
U2CRT (2)
Brown 10
1-5/16
3/4
.60
1.25 .11
5/16
3/4
.60
1.25 .11
3/8
1-3/4
.60
1.25 .11
v
See tooling section of this catalog for complete tool and die listings.
* Use P-UADP-1 adaptor with "U" -dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, P-UADP-1 adapter not required.
*** The MM
2
conductor sizes listed are the recommendations for Class 2 conductor.
" Available undrilled. Add suffix "U" to catalog number (example: YA25U).
x
For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions.
BURNDY
Compression
TWO HOLE HYLUG™
CODE CONDUCTOR
LONG BARREL
(CONTINUED)
Conductor
Catalog Number
C-50
YA2C2TC38
YA2C2TC38-45
YA2C2TC38-90
YA2C2TC38E6
YA2C2TC38E6-45
YA2C2TC38E6-90
YA2C2TC516E2
YA2C2TC516E2-45
YA2C2TC516E2-90
YA1C2N
YA1C2N-45
YA1C2N-90
YA1C2TC14
YA1C2TC14-45
YA1C2TC14-90
YA1C2TC14E2
YA1C2TC14E2-45
YA1C2TC14E2-90
YA1C2TC38
YA1C2TC38-45
YA1C2TC38-90
YA252N
YA252N-45
YA252N-90
YA252TC14
YA252TC14-45
YA252TC14-90
YA252TC14E2
YA252TC14E2-45
YA252TC14E2-90
YA252TC38
YA252TC38-45
YA252TC38-90
YA252TC516
YA252TC516-45
YA252TC516-90
YA252NTC38
YA252NTC38-45
YA252NTC38-90
YA262N
YA262N-45
YA262N-90
YA262TC14
YA262TC14-45
YA262TC14-90
YA262TC14E2
YA262TC14E2-45
YA262TC14E2-90
Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
AWG
***
MM
2
Stud Stud
Hole Hole Tongue
Size Spacing Width
3/8
1
.60
Figure
Dimensions
(B) (T)
(L)
3.42
1.25 .11 3.22
2.14
3.30
1.25 .11 3.10
2.02
3.05
1.25 .11 2.84
1.77
4.82
1.38 .12 4.58
3.36
3.03
1.38 .10 2.76
1.60
3.15
1.38 .10 2.88
1.73
3.59
1.38 .10 3.32
2.16
4.81
1.38 .11’ 4.56
3.38
3.05
1.38 .12 2.82
1.64
3.18
1.38 .12 2.94
1.76
3.62
1.38 .12 3.38
2.20
3.49
1.38 .12 3.26
2.08
4.37
1.38 .12 4.13
2.95
4.97
1.50 .12 4.69
3.41
3.22
1.50 .12 2.94
1.66
3.34
1.50 .12 3.06
1.79
Dieless
(# of crimps)
B
B
90°
T
45°
B
T
L
T
L
L
Fig. 1
Fig. 2
Mechanical
MD6, OUR840
MD7-34R
Fig. 3
v
Installation Tooling
Hydraulic
Wire
BCT500HS
Y35,Y39,Y750 Color Die Strip
Y500CTHS Y46, BAT35, BAT750 Code Index Length
#2 AWG
35
3/8
7/8
.60
5/16
3/4
.60
Y1MR (4)
Y2MR (4)
MY29-3 (2)
MY29-11 (2)
MRC840 (2)
Y644M (1)
W2CVT (2)
W2CRT (2)
X2CRT (2)
W2CVT (2)
W2CRT (2)
X2CRT (2)
U2CRT (2)
Brown 10
1-5/16
1/2
1-3/4
.81
1/4
1 AWG
50
1/4
5/8
.68
3/4
.75
Y1MR (4)
MY29-3 (2) W1CVT (2) W1CVT (2)
MY29-11 (2) W1CRT-1 (2) W1CRT-1 (2)
MRC840 (2) X1CRT-1 (2) X1CRT-1 (2)
Y644M (1)
U1CRT-1 (2)
U4CABT (2)
Green 11
1-1/2
3/8
1
.68
1/2
1-3/4
.81
1/4
5/8
.75
1/4
1/0 AWG
-
3/8
3/4
.75
1
.75
W25VT (4)
W25RT (4)
X25RT (4)
MY29-3 (2)
MY29-11 (2)
MRC840 (4)
Y644M (1)
W25VT (4)
W25RT (4)
X25RT (4)
U25RT (2)
U2CABT (2)
Pink
12
1-7/16
5/16
1
.75
3/8
1-3/4
.75
1/2
1-3/4
.83
.
.83
.
.83
2/0 AWG
70
1/4
5/8
W26VT (4)
W26RT (4)
X26RT (4)
W26VT (4)
W26RT (4)
X26RT (4)
U26RT (2)
Black
13
1-9/16
1/4
3/4
v
See tooling section of this catalog for complete tool and die listings.
* Use P-UADP-1 adaptor with "U" -dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, P-UADP-1 adapter not required.
*** The MM
2
conductor sizes listed are the recommendations for Class 2 conductor.
" Available undrilled. Add suffix "U" to catalog number. (Example: YA25U).
x
For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions.
BURNDY
Compression
TWO HOLE HYLUG™
CODE CONDUCTOR
LONG BARREL
(CONTINUED)
Conductor
Catalog Number
YA262TC38
YA262TC38-45
YA262TC38-90
YA272N
YA272N-45
YA272N-90
YA272TC14E2
YA272TC14E2-45
YA272TC14E2-90
YA272TC38
YA272TC38-45
YA272TC38-90
YA282N
YA282N-45
YA282N-90
YA282TC38
YA282TC38-45
YA282TC38-90
YA282TC14E2
YA282TC14E2-45
YA282TC14E2-90
YA282NTC38
YA282NTC38-45
YA282NTC38-90
YA292N
YA292N-45
YA292N-90
YA292TC38
YA292TC38-45
YA292TC38-90
YA302TC38
YA302TC38-45
YA302TC38-90
YA302N
YA302N-45
YA302N-90
YA312N
YA312N-45
YA312N-90
YA312TC14E2
YA312TC14E2-45
YA312TC14E2-90
YA312TC38
YA312TC38-45
YA312TC38-90
YA322N
YA322N-45
YA322N-90
Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
AWG
***
MM
2
Stud Stud
Hole Hole Tongue
Size Spacing Width
3/8
1
.83
Figure
Dimensions
(B) (T)
(L)
3.78
1.50 .12 3.50
2.22
5.01
1.50 .13 4.73
3.44
3.38
1.50 .12 3.10
1.82
3.82
1.50 .12 3.54
2.25
5.17
1.62 .14 4.88
3.49
3.99
1.62 .14 3.69
2.30
3.55
1.62 .14 3.25
1.86
4.74
1.62 .14 4.44
3.05
5.21
1.62 .16 4.94
3.52
4.02
1.62 .16 3.75
2.34
4.45
2.00 .16 4.07
2.37
5.64
2.00 .16 5.26
3.56
5.68
2.00 .18 5.31
3.60
4.05
2.00 .18 3.68
1.97
4.49
2.00 .18 4.12
2.41
5.85
2.12 .19 5.47
3.64
Dieless
(# of crimps)
B
B
90°
T
45°
B
T
L
T
L
L
Fig. 1
Fig. 2
Fig. 3
v
Installation Tooling
Mechanical
Hydraulic
Wire
MD6, OUR840 BCT500HS
Y35,Y39,Y750 Color Die Strip
MD7-34R
Y500CTHS Y46, BAT35, BAT750 Code Index Length
W26VT (4) W26VT (4)
W26RT (4) W26RT (4)
U26RT (2)
Black 13 1-9/16
X26RT (4) X26RT (4)
C-51
1/2
3/0 AWG
-
1/4
1-3/4
.91
3/4
.91
W27VT (4)
W27RT (4)
X27RT (6)
MY29-3 (2)
MY29-11 (2)
MRC840 (4)
Y644M (1)
W27VT (4)
W27RT (4)
X27RT (6)
U27RT (2)
Orange 14
1-9/16
3/8
1
.90
1/2
1-3/4
1.02
3/8
4/0 AWG
-
1/4
1
1.02
3/4
1.02
W28VT (4)
W28RT (4)
X28RT (6)
W28VT (4)
W28RT (4)
X28RT (6)
U28RT (2)
Purple
15
1-11/16
3/8
1-3/4
1.02
1/2
250 kcmil
-
3/8
1-3/4
1.11
1
1.10
MY29-3 (2)
MY29-11 (2)
Y644M (1)
W29VT (4)
X29RT (8)
W29VT (4)
W29RT (4)
X29RT (8)
U29RT (2)
Yellow 16
1-11/16
3/8
300 kcmil
150
1/2
1
1.20
W30VT (4)
W30VT (4)
W30RT (4)
U30RT (4)
U28ART (4)
White
17
2
1-3/4
1.20
1/2
1-3/4
1.29
Y644M (1)
W31VT (4)
W31VT (4)
W31RT (4)
U31RT (4)
U29ART (4)
Red
18
2-1/16
350 kcmil
185
1/4
3/4
1.29
3/8
1
1.29
400 kcmil
-
1/2
1-3/4
1.38
W32VT (4)
W32VT (4)
W32RT (4)
U32RT (4)
U30ART (4)
Blue
19
2-3/16
v
See tooling section of this catalog for complete tool and die listings.
* Use P-UADP-1 adaptor with "U" -dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, P-UADP-1 adapter not required.
*** The MM
2
conductor sizes listed are the recommendations for Class 2 conductor.
" Available undrilled. Add suffix "U" to catalog number (example: YA25U).
x
For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions.
BURNDY
Compression
TWO HOLE HYLUG™
CODE CONDUCTOR
LONG BARREL
(CONTINUED)
Conductor
Catalog Number
C-52
YA322TC38
YA322TC38-45
YA322TC38-90
YA332N
YA332N-45
YA332N-90
YA342N
YA342N-45
YA342N-90
YA342TC14E2
YA342TC14E2-45
YA342TC14E2-90
YA342TC38
YA342TC38-45
YA342TC38-90
YA352N
YA352N-45
YA352N-90
YA362N
YA362N-45
YA362N-90
YA362TC38
YA362TC38-45
YA362TC38-90
YA372N
YA372N-45
YA372N-90
YA382N
YA382N-45
YA382N-90
YA382TC38
YA382TC38-45
YA382TC38-90
YA392N
YA392N-45
YA392N-90
YA392NT38
YA392NT38-45
YA392NT38-90
YA392TC38
YA392TC38-45
YA392TC38-90
YA402N
YA402N-45
YA402N-90
YA412N
YA412N-45
YA412N-90
Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
AWG
450 kcmi
***
MM
2
-
Stud Stud
Hole Hole Tongue
Size Spacing Width
3/8
1
1.38
Figure
Dimensions
(B) (T)
(L)
4.66
2.12 .19 4.28
2.46
5.93
2.12 .21 5.57
3.70
6.06
2.25 .23 5.72
3.73
4.46
2.25 .23 4.09
2.10
4.90
2.25 .23 4.53
2.54
6.49
2.63 .25 6.06
3.77
6.59
6.17
2.69 .27 3.81
5.59
2.69 .26 5.17
2.81
6.74
2.81 .27 6.29
3.84
6.77
2.81 .27 6.29
3.84
5.76
2.81 .27 5.29
2.84
6.87
2.88 .27 6.38
3.87
5.87
2.88 .27 5.38
2.87
5.87
2.88 .27 5.38
2.87
6.95
2.94 .30 6.50
3.91
6.96
2.94 .31 6.52
3.93
Dieless
(# of crimps)
B
B
90°
T
45°
B
T
L
T
L
L
Fig. 1
Fig. 2
Mechanical
MD6, OUR840
MD7-34R
W32VT (4)
Fig. 3
v
Installation Tooling
Hydraulic
Wire
BCT500HS
Y35,Y39,Y750 Color Die Strip
Y500CTHS Y46, BAT35, BAT750 Code Index Length
W32VT (4)
W32RT (4)
W33VT (4)
W33RT (4)
U32RT (4)
U30RT (4)
U33RT
Blue
19
2-3/16
450 kcmi
-
1/2
1-3/4
1.48
W33VT (4)
Gray
326 2-5/16
1/2
1-3/4
1.52
500 kcmil
240
1/4
3/4
1.55
W34VT (4)
W34VT (4)
W34RT (4)
U34RT (4)
U31ART (4)
Brown
20
2-1/2
3/8
1
1.55
550 kcmil
-
1/2
1-3/4
1.65
-
-
U35RT (4)
Yellow
21
2-11/16
1/2
600 kcmil
300
3/8
1-3/4
1.69
-
Y644M (1)
-
-
U36RT (4)
U32ART (4)
Green
22
2-3/4
1
1.74
650 kcmil
-
1/2
1-3/4
1.80
-
U37RT (4)
Orange 23
2-7/8
1/2
700 kcmil
-
3/8
1-3/4
1.84
-
-
U38RT (4)
Pink
400
2-7/8
1
1.84
1/2
1-3/4
1.89
750 kcmil
-
3/8
1
1.63
-
-
U39RT (4)
P39RT (4)
**
Black
24
2-3/4
3/8
1
1.91
800 kcmil
400
1/2
1-3/4
1.95
-
-
P40RT (4)
**
-
Orange 25
3
850 kcmil
-
1/2
1-3/4
2.01
-
-
Gold
26
3
v
See tooling section of this catalog for complete tool and die listings.
* Use P-UADP-1 adaptor with "U" -dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, P-UADP-1 adapter not required.
*** The MM
2
conductor sizes listed are the recommendations for Class 2 conductor.
" Available undrilled. Add suffix "U" to catalog number (example: YA25U).
x
For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions.