FLAT TYPE POWER RELAY
JV RELAYS
22
.866
16
.630
FEATURES
10.9
.429
mm
inch
• Flat type: 16 mm (length)
×
22 mm (width)
×
10.9 mm (height)
(.630
×
.866
×
.429 inch)
• High capacity type (16A) available
• High sensitivity type (100 mW: 1 Form A) available
• TÜV also approved
SPECIFICATIONS
Contact
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material
Nominal switching
capacity
Rating
(resistive)
Max. switching power
Max. switching voltage
Max. switching current
Expected life (min. ope.)
Mechanical at (180 cpm)
Electrical at resistive
Sealed type
(at 20 cpm)
Flux-resistant
(at rated load)
type
Standard type
1 Form A
1 Form C
High capacity
High
type
sensitivity type
1 Form A
1 Form A
Characteristics
Max. operating speed
Initial insulation resis-
tance*
1
Initial
break-
down
voltage*
2
Between open
contacts
Between con-
tacts and coil
20 cpm
Min. 100 M
Ω
(at 500 V DC)
1,000 Vrms
for 1 min.
1,500 Vrms
for 1 min.
Approx. 10 ms
Approx. 5 ms
(100 V DC coil type)
Approx. 4 ms
Max. 65
°
C with nominal
coil voltage across
coil and at nominal
switching capacity
50 m
Ω
Silver alloy
10 A 125 V AC (N.O.)
10 A 125 V AC
16 A 125 V AC 10 A 125 V AC
6 A 125 V AC (N.C.)
1,250 VA (N.O.)
1,250 VA
2,000 VA
1,250 V
750 VA (N.C.)
125 V AC
10 A
10 A (N.O.)
6 A (N.C.)
10
7
10
5
3
×
10
5
1 Form A type
10
5
10
5
3
×
10
4
10
5
5
×
10
4
10
5
16 A
10 A
Operate time*
3
(at nominal voltage)
Release time (without diode)*
3
(at nominal voltage)
Temperature rise
(at 50°C)
Functional*
4
Shock
resistance
Destructive*
5
Functional*
6
Min. 98 m/s
2
{10 G}
Min. 980 m/s
2
{100 G}
10 to 55 Hz
at double amplitude
of 1.0 mm
Coil
1 Form C type
400 mW (up to 48 V coil type)
600 mW (100 V coil type)
—
—
200 mW (up to 48 V coil type)
Nominal Standard type
600 mW (100 V coil type)
operating
High capacity type
power
High sensitivity type
100 mW
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as "Initial breakdown voltage"section
*
2
Detection current: 10mA
*
3
Excluding contact bounce time
*
4
Half-wave pulse of sine wave: 11ms, detection time: 10
µ
s
*
5
Half-wave pulse of sine wave: 6ms
*
6
Detection time: 10
µ
s
*
7
Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT .
*
8
100V type: –40 to + 60
°
C
–40 to + 140
°
F
10 to 55 Hz
at double amplitude
of 1.6 mm
Conditions for opera-
Ambient –40
°
C to +70
°
C*
8
tion, transport and
temp.
–40
°
F to +158
°
F
storage*
7
(Not freezing and
Humidity
5 to 85%R.H.
condensing at low
temperature)
Unit weight
Approx. 8 g
.282 oz
Destructive
Vibration
resistance
TYPICAL APPLICATIONS
1. Home appliances: Air conditioner, heater, etc.
2. Automotive: Power supply for car stereo and air conditioner
ORDERING INFORMATION
Ex. JV
Contact arrangement
1: 1 Form C
1a: 1 Form A
Rating
Nil: Standard type
P: High capacity type*
1a
P
F
S
12V
Coil voltage (DC)
5, 6, 9, 12, 18,
24, 48, 100V
Protective construction
Nil: Sealed type
F: Flux-resistant type
Sensitivity
Nil: Standard type
(1 Form A: 200 mW, 1Form C: 400 mW
100 V DC coil type: 600 mW)
S: High sensitivity type*
(1 Form A: 100 mW)
Notes: 1. Standard packing: Carton: 50 pcs.; Case: 1,000 pcs.
2. Coil voltage DC 48, 100 V types are not available for high sensitivity type.
UL/CSA, TÜV approved type is standard.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
* Only for 1 Form A type
JV
TYPES
Contact arrangement
Coil voltage, V DC
5
6
9
12
18
24
48
100
5
6
1 Form A
High capacity type
9
12
18
24
48
100
5
6
9
12
18
24
5
6
9
12
18
24
48
100
Part No.
Sealed type
Flux-resistant type
JV1a-5V
JV1a-6V
JV1a-9V
JV1a-12V
JV1a-18V
JV1a-24V
JV1a-48V
JV1a-100V
JV1aP-5V
JV1aP-6V
JV1aP-9V
JV1aP-12V
JV1aP-18V
JV1aP-24V
JV1aP-48V
JV1aP-100V
JV1aS-5V
JV1aS-6V
JV1aS-9V
JV1aS-12V
JV1aS-18V
JV1aS-24V
JV1-5V
JV1-6V
JV1-9V
JV1-12V
JV1-18V
JV1-24V
JV1-48V
JV1-100V
JV1aF-5V
JV1aF-6V
JV1aF-9V
JV1aF-12V
JV1aF-18V
JV1aF-24V
JV1aF-48V
JV1aF-100V
JV1aPF-5V
JV1aPF-6V
JV1aPF-9V
JV1aPF-12V
JV1aPF-18V
JV1aPF-24V
JV1aPF-48V
JV1aPF-100V
JV1aFS-5V
JV1aFS-6V
JV1aFS-9V
JV1aFS-12V
JV1aFS-18V
JV1aFS-24V
JV1F-5V
JV1F-6V
JV1F-9V
JV1F-12V
JV1F-18V
JV1F-24V
JV1F-48V
JV1F-100V
1 Form A
Standard type
1 Form A
High sensitivity type
1 Form C
COIL DATA (at 20
°
C
68
°
F)
Part No.
Nominal voltage,
V DC
5
6
1 Form A
(Standard type &
High capacity
type)
9
12
18
24
48
100
5
1 Form A
(High sensitivity
type)
6
9
12
18
24
5
6
9
1 Form C
12
18
24
48
100
Pick-up voltage,
V DC (max.)
4.0
4.8
7.2
9.6
14.4
19.2
38.4
48
4.0
4.8
7.2
9.6
14.4
19.2
4.0
4.8
7.2
9.6
14.4
19.2
38.4
70
Drop-out
voltage,
V DC (min.)
0.25
0.3
0.45
0.6
0.9
1.2
2.4
3
0.25
0.3
0.45
0.6
0.9
1.2
0.25
0.3
0.45
0.6
0.9
1.2
2.4
5
Coil resistance,
Ω
(
±
10%)
125
180
405
720
1,620
2,880
11,520
16,600
250
360
810
1,440
3,240
5,760
62.5
90
202.5
360
810
1,440
5,760
16,600
Nominal operat-
ing current, mA
(
±
10%)
40
33.3
22.2
16.7
11.1
8.3
4.2
6
20
16.7
11.1
8.3
5.6
4.2
80
66.7
44.4
33.3
22.2
16.7
8.3
6
Nominal
operating power,
mW
200
200
200
200
200
200
200
600
100
100
100
100
100
100
400
400
400
400
400
400
400
600
Max. allowable
voltage,
V DC
7.5
9
13.5
18
27
36
72
110
9
10.8
16.2
21.6
32.4
43.2
6.5
7.8
11.7
15.6
23.4
31.2
62.4
110
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
JV
DIMENSIONS
1 Form A type
22
.866
10.5
0.4
.413
.016
4
.157
17.78
.700
2
1
mm
inch
1 Form C type
16
.630
22
.866
10.5
0.4
.413
.016
4
.157
16
.630
PC board pattern (Copper-side view)
17.78
.700
12.7
.500
2-0.9 dia.
2-.035 dia.
2
17.78
.700
1
PC board pattern (Copper-side view)
17.78
.700
12.7
.500
2-0.9 dia.
2-.035 dia.
COM
3
NO
4
NC
5
12.7
.500
COM
3
NO
4
NC
5
12.7
.500
10.16
.400
2-1.3 dia.
2-.051 dia.
10.16
.400
10.16
.400
7.62
.300
3-1.3 dia.
3-.051 dia.
Dimension :
Max. 1mm
.039 inch
1 to 5mm
.039 to .197 inch
Min. 5mm
.197 inch
General tolerance
±
0.2
±
.008
±
0.3
±
.012
±
0.4
±
.016
Tolerance:
±
0.1
±
.004
Dimension :
Max. 1mm
.039 inch
1 to 5mm
.039 to .197 inch
Min. 5mm
.197 inch
General tolerance
±
0.2
±
.008
±
0.3
±
.012
±
0.4
±
.016
10.16
.400
7.62
.300
Tolerance:
±
0.1
±
.004
REFERENCE DATA
1.-(1) Maximum value for switching capacity
(1 Form A type)
100
1.-(2) Maximum value for switching capacity
(1 Form C type)
100
2.-(1) Operate/release time
(Standard 1 Form A type)
Operate/release time, ms
18
16
14
12
10
8
6
4
2
Release time
Max.
–
x
Min.
Max.
–
x
Min.
140
160
180
Operate time
Contact current, A
16
10
Standard type, AC resistive load
Contact current, A
High capacity type, AC resistive load
10
AC resistive load (NO side)
1
1
10
100
Contact voltage, V
1,000
10
100
Contact voltage, V
1,000
0
80
100
120
Coil applied voltage, %V
2.-(2) Operate/release time
(High capacity 1 Form A type)
Operate/release time, ms
18
16
14
12
10
8
6
4
2
0
80
100 120
140 160
Release time
Max.
–
x
Min.
Max.
–
x
Min.
180
Operate time
2.-(3) Operate/release time (1 Form C type)
3.-(1) Coil temperature rise (1 Form A type)
Measured portion: Inside the coil
15 A at 26°C
79°F
(High capacity type)
80
15 A at 60°C
140°F
(High capacity type)
60
10 A at
15°C
59°F
(Standad type)
10 A at
60°C
140°F
(Standad type)
Operate/release time, ms
10
8
Operate time
6
4
Release time
2
Max.
–
x
Min.
Max.
–
x
Min.
140
160
Temperature rise,
°C
40
20
0
80
100
120
0
80
100
120
140 160
180
Coil applied voltage, %V
Coil applied voltage, %V
Coil applied voltage, %V
3.-(2) Coil temperature rise
(1 Form C type)
Measured portion: Inside the coil
3.-(3) Coil temperature rise
(High sensitivity type)
Measured portion: Inside the coil
60
Standard 200 mW type
4. Life curve
Operation frequency: 20 times/min.
(ON/OFF = 1.5s:1.5s)
Ambient temperature: Room temperature
100
125V AC resistive load
Temperature rise,
°C
80
10 A
at 25°C
77°F
60
Temperature rise,
°C
Life,
×10
4
High sensitivity 100 mW type
0 100
120
140
160
180
200
40
10
40
20
20
0
80
100
120
140 160
180
0
1
4
6
8
10
12
14
16
18
Coil applied voltage, %V
Coil applied voltage, %V
Contact current, A
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
JV
5.-(1) Ambient temperature characteristics
(Standard 10 A type, 1 Form A)
Contact current: 10 A
5.-(2) Ambient temperature characteristics
(High capacity 15 A type, 1 Form A)
Contact current: 0 A, 10 A, 13 A, 15 A
0
300
5.-(3) Ambient temperature characteristics
(1 Form C type)
Contact current: 10 A
Coil applied voltage, %V
Coil applied voltage, %V
300
Allowable ambient temperatures
against % coil voltage
(max. inside the coil temperature
set as 115°C
239°F)
A
Coil applied voltage, %V
200
Pick-up voltage with
a hot-start condition
of 100%V on the coil
200
100
Pick-up voltage
100
0
20
40
60
80
100
120
0
Allowable ambient
temperature against
% coil voltages
(max. inside the coil
temperature set as
13 A 15 A
115°C
239°F)
Pick-up voltage with
a hot-start condition
of 100%V on the coil
10 A Pick-up voltage
0A
20
40
60 80 100 120
Ambient temperature,
°C
A
13
A
15
A
10
200
Allowable ambient temperatures
against % coil voltages
(max. inside the coil temperature
set as 115°C
239°F)
Pick-up voltage
100
0
20
40
60
80
Ambient temperature,
°C
Ambient temperature,
°C
5.-(4) Ambient temperature characteristics
(High sensitivity type)
Contact current: 10 A
300
Coil applied voltage, %V
High sensitivity
100 mW type
200
Standard
200 mW type
Allowable ambient
temperature
against % coil
voltages (max.
inside the coil temperature
set as 115°C
239°F)
100
0
0
20
40
60
80
100
120
Temperature rise,
°C
Types dedicated to a wider variety of automotive applications are available, upon receipt of order, with the following specifications:
SPECIFICATIONS
Contact
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material
Nominal switching capacity
Rating
(resistive Max. switching power
load)
Max. switching voltage
Max. switching current
Mechanical (at 300 cpm)
Expected
life (min. Electrical
(DC 12 V motor, 6 A steady current,
ope.)
20 A lock current)(at rated load)
1 Form C
100 m
Ω
Silver alloy
10 A 125 V AC
6A 30 V DC
1,250 V AC
180 W
125 V (AC) 30 V (DC)
10 A (AC) 6 A (DC)
5
×
10
6
4
×
10
4
Characteristics
Max. operating speed
Initial insulation resistance
Initial break Between open contacts
down voltage
Between contacts and coil
Operate time (at nominal voltage)
Release time (at nominal voltage)
Temperature rise (max.)
(at nominal voltage)(at 50°C)
Functional
Shock resistance
Destructive
Functional
Vibration resistance
Destructive
5, 6, 9, 12, 18, 24
450 mW
70% of nominal voltage
5% of nominal voltage
150% of nominal voltage
Conditions for operation,
Ambient
temp.
transport and storage
(Not freezing and condens-
Humidity
ing at low temperature)
20 cpm
Min. 100 M
Ω
(at 500 V DC)
750 Vrms for 1 min.
1,500 Vrms for 1 min.
Approx. 5 ms
Approx. 4 ms
Coil
Nominal voltage, V DC
Nominal operating power
Pick-up voltage, V DC (max.)
Drop-out voltage; V DC (min.)
Max. allowable voltage
65°C with nominal coil voltage and at
maximum allowable contact current
Min. 196 m/s
2
{20 G}
Min. 980 m/s
2
{100 G}
10 to 55 Hz at double amplitude of
1.6 mm
10 to 55 Hz at double amplitude of
2 mm
–40°C to +70°C
–40°F to +158°F
5 to 85%R.H.
Approx. 8 g
.282 oz
Unit weight
For Cautions for Use, see Relay Technical Information.