EEWORLDEEWORLDEEWORLD

Part Number

Search

218630

Description
Wire And Cable, 1 Conductor(s), 300V, Flexible Cord And Fixture Wire, HALOGEN FREE
CategoryThe connector    Connector bracket   
File Size119KB,2 Pages
ManufacturerLeoni Kerpen GmbH
Download Datasheet Parametric Compare View All

218630 Overview

Wire And Cable, 1 Conductor(s), 300V, Flexible Cord And Fixture Wire, HALOGEN FREE

218630 Parametric

Parameter NameAttribute value
package instructionHALOGEN FREE
Reach Compliance Codeunknown
Other featuresFLAME RESISTANT, APPLICATION: SWITCH BOARDS AND DISTRIBUTION BOXES, MECHANICAL OR PLANT ENGINEERING
applicationINTERNAL WIRING IN LAMPS, HEATING APPLIANCES
CertificationGOST; VDE
conductor materialBARE COPPER
Connector bracket typeWIRE AND CABLE
structureSTRANDED
Cross-sectional area0.5 mm2
diameter2.2 mm
insulator materialPOLYOLEFINE COPOLYMER
Number of conductors1
Maximum operating temperature110 °C
Minimum operating temperature-40 °C
Rated voltage300 V
shieldNO
Wire and Cable NamesFLEXIBLE CORD AND FIXTURE WIRE
Base Number Matches1
BETAtherm®
Aderleitung mit erhöhter Umweltverträglichkeit
BETAtherm® 110
BETAtherm® 110
≤ 1 mm² H05Z - K, ≥ 1,5 mm² H07Z - K
Single core with increased environmental compatibility
≤ 1
mm² H05Z - K,
≥ 1,5
mm² H07Z - K
Anwendung
Geeignet für die Verlegung in Rohren, auf, in und unter Putz sowie in geschlosse-
nen Installationskanälen. Nicht zugelassen ist die Verlegung auf Pritschen, Rinnen
oder Wannen. Typische Anwendungsbereiche sind innere Verdrahtungen von
Leuchten, Wärmegeräten, Schaltanlagen und Verteilern im Apparate-, Maschinen-
und Anlagenbau. Bei Verwendung oberhalb von 90 °C bis höchstens 110 °C ist mit
einer unbedeutenden Verringerung der Gebrauchsdauer zu rechnen.
Aufbau
Leiter:
Kupferlitze blank, feindrähtig nach VDE 0295 / IEC 60228, Klasse 5
Isolation:
Polyolefin Copolymer elektronenstrahlvernetzt
Aderfarben:
Grün-gelb, schwarz, hellblau, braun, rot, weiss, dunkelblau und
grau
Technische Daten
Nennspannung:
U₀/U ≤ 1 mm
2
300 / 500 V
2
U₀/U ≥
1,5 mm
450 / 750 V
Bei fester und geschützter Verlegung U₀/U ≥
1,5 mm
2
600 / 1000 V
Prüfspannung:
5000 V
Max. Leitertemperatur:
Fest verlegt
+ 110 °C
Gelegentlich bewegt + 90 °C
Kurzschluss
+ 280 °C
Min. Umgebungstemperatur:
Fest verlegt
– 40 °C
Gelegentlich bewegt – 25 °C
Min. Biegeradius:
Fest verlegt
> 4
×
Aussen-
Gelegentlich bewegt > 6
×
Aussen-
Normen / Materialeigenschaften
Halogenfrei:
IEC 60754-1, EN 50267-2-1
Keine korrosiven Gase:
IEC 60754-2, EN 50267-2-2
Keine toxischen Gase:
NES 02-713, NF X 70-100
Geringe Rauchentwicklung:
IEC 61034, EN 50268-2
Flammwidrig:
IEC 60332-1, EN 50265-2-1
Keine Brandfortleitung:
IEC 60332-3, EN 50266-2
Geringe Brandlast:
DIN 51900
Zulassung VDE:
Zertifikat Nr. 98673
Zulassung Gost R:
Zertifikat Nr. 83 B 00 682
Besonderheiten
Spezialausführungen und UL-Sortiment auf Anfrage,
Zulassung AWM Style 3666 vorhanden
Application
Used for laying in tubes, surface wiring, direct in plaster or underneath it, as well in
conduits. May not be laid directly in cable trays, cable racks or cable troughs. Typical
applications are internal wiring in lamps, heating applications, switchboards and
distribution boxes in apparatus, mechanical or plant engineering. When used above
90 °C and up to maximum 110 °C a minor reduction of their service life is to be expect-
ed.
Construction
Conductor:
Bare fine copper strands according to VDE 0295 / IEC 60228, class 5
Insulation:
Polyolefine copolymer electron-beam cross-linked
Colour of conductors:
Green-yellow, black, lightblue, brown, red, white, darkblue
and grey
Technical data
Nomimal voltage:
U₀/U
1 mm
2
300 / 500 V
2
U₀/U
1,5 mm
450 / 750 V
For fixed and protected installation U₀/U
1,5 mm
2
600 / 1000 V
Testing voltage:
5000 V
Max. conductor temperature:
Fixed installation + 110 °C
Occasionally moved + 90 °C
Short circuit
+ 280 °C
Min. ambient temperature:
Fixed installation – 40 °C
Occasionally moved – 25 °C
Min. bending radius:
Fixed installation > 4 × outer
Occasionally moved > 6 × outer
Standard specifications / Material properties
Halogen free:
IEC 60754-1, EN 50267-2-1
No corrosive gases:
IEC 60754-2, EN 50267-2-2
No toxic gases:
NES 02-713, NF X 70-100
Low smoke density:
IEC 61034, EN 50268-2
Flame retardant:
IEC 60332-1, EN 50265-2-1
Non-flame propagating:
IEC 60332-3, EN 50266-2
Low fire load:
DIN 51900
Approval VDE:
Certificate no. 98673
Approval Gost R:
Certificate no. 83 B 00 682
Specialities
Special types and UL range of products upon request,
approval AWM style 3666 available
www.leoni-studer.ch
Juni 2009
16

218630 Related Products

218630 215270 217855
Description Wire And Cable, 1 Conductor(s), 300V, Flexible Cord And Fixture Wire, HALOGEN FREE Wire And Cable, 1 Conductor(s), 450V, Flexible Cord And Fixture Wire, HALOGEN FREE Wire And Cable, 1 Conductor(s), 450V, Flexible Cord And Fixture Wire, HALOGEN FREE
package instruction HALOGEN FREE HALOGEN FREE HALOGEN FREE
Reach Compliance Code unknown unknown unknow
Other features FLAME RESISTANT, APPLICATION: SWITCH BOARDS AND DISTRIBUTION BOXES, MECHANICAL OR PLANT ENGINEERING FLAME RESISTANT, APPLICATION: SWITCH BOARDS AND DISTRIBUTION BOXES, MECHANICAL OR PLANT ENGINEERING FLAME RESISTANT, APPLICATION: SWITCH BOARDS AND DISTRIBUTION BOXES, MECHANICAL OR PLANT ENGINEERING
application INTERNAL WIRING IN LAMPS, HEATING APPLIANCES INTERNAL WIRING IN LAMPS, HEATING APPLIANCES INTERNAL WIRING IN LAMPS, HEATING APPLIANCES
Certification GOST; VDE GOST; VDE GOST; VDE
conductor material BARE COPPER BARE COPPER BARE COPPER
Connector bracket type WIRE AND CABLE WIRE AND CABLE WIRE AND CABLE
structure STRANDED STRANDED STRANDED
Cross-sectional area 0.5 mm2 1.5 mm2 2.5 mm2
diameter 2.2 mm 3 mm 3.7 mm
insulator material POLYOLEFINE COPOLYMER POLYOLEFINE COPOLYMER POLYOLEFINE COPOLYMER
Number of conductors 1 1 1
Maximum operating temperature 110 °C 110 °C 110 °C
Minimum operating temperature -40 °C -40 °C -40 °C
Rated voltage 300 V 450 V 450 V
shield NO NO NO
Wire and Cable Names FLEXIBLE CORD AND FIXTURE WIRE FLEXIBLE CORD AND FIXTURE WIRE FLEXIBLE CORD AND FIXTURE WIRE
Base Number Matches 1 1 -
【GD32307E-START】DAC+ADC test
In the previous article, I completed the development environment of the GD32 307 START development board and wrote a simple LED flashing program. In this article, I will test the DAC and ADC functions...
我的名字真的真的很长 GD32 MCU
Can someone help me analyze what this circuit does?
WE-VOUT is a signal input to LM321. R1 and R4 can be welded or not. What is this circuit used for?...
li6666 Analog electronics
Ding~ You have a review information waiting to be received~ Please open this post to view
Every day is a new beginning, and the evaluation information for the new week is here~ This week, there are new evaluation activities online, and the application period for the activities has ended. T...
okhxyyo Special Edition for Assessment Centres
Simple stopwatch based on MSP430f149 MCU
Function: Press a button to start timing, press the button again to pause timing, that is, one button can realize the pause and start function, set another button, press the button for more than three...
fish001 Microcontroller MCU
Op amp circuit waveform analysis problem
As shown in Figure 1, the input of the op amp is 220VAC (there is a string of voltage-dropping resistors before R1 and R2 that are omitted) The waveform measured at point A is indeed the same as the t...
shaorc Analog electronics

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号