Type
Cold Cathode Lamp Inverter Drive module
5VDC input
Connector system
JST XHP-2
Part No.
INV 10 (O1- 100-020K)
CCFL output
Connector system
JST XHP-3
- +
TR1
R1
C1
L1
R2
TR2
C2
T1
L70 x W20 x H15
Drawing not to scale
All dimensions in mm
CHARACTERISTIC DATA
Single Output suitable for CCFL length:
Input Voltage
Input Current
No Load Output Voltage
Lamp Output Voltage (V
L
)
Nominal Drive current (I
L
)
Operating frequency (f)
Operating temperature
Operating humidity
Operating life
150 ~ 280 mm
5.0VDC ± 0.5V
850 mA maximum
1100V rms minimum, 1350V rms nominal
550V rms nominal
5 mA ± 1mA
39 ± 5 kHz
0 ~ 50 ºC
5 ~ 70% RH
20,000 hours @ 5.5VDC
NOTES:
1. The inverter module should be protected from moisture, condensation and freezing.
2. Suitable screening may be necessary for electromagnetic compatibility and protection.
3. The use of silicone rubber stranded wire is recommended for connecting the CFFL.
4. Danger of electric shock.