CN-A24 Series
50 & 100W 14.4 to 36VDC Input DC-DC Converters
Features
14.4 - 36VDC Input
IEC 61373 Shock and Vibration
Base-plate Cooled
Full Power at 100°C base plate
Small Size
Quarter Brick Footprint
Wide input range
Key Market Segments & Applications
Specifications
Model
Nominal Output Voltage
Input Voltage Range
Input Current
Output Voltage Adjustment
Ripple & Noise (max) pk-pk
Line Regulation (max)
Load Regulation (max)
Overcurrent Protection
Overvoltage Protection
Remote Sense
Remote On/Off
Operating Temperature
Storage Temperature
Temperature Coefficient
Humidity (non condensing)
Cooling
Withstand Voltage
Isolation Resistance
Vibration
(1)
12V
24V
14.4 - 36VDC (40V transient for 3 seconds)
2.48 - 4.91A (model dependant)
4.5 - 6
10.8 - 13.2
21.6 - 26.4
100
150
240
20
48
96
40
96
192
105 - 140%
125 - 145% (Cycle input or remote on/off to reset)
Yes
Yes; Low = ON, Open = OFF
-40°C to +100°C Baseplate
-40°C to +100°C
0.02%/°C
5 - 95% RH Operating and Non Operating
Conduction (See Installation Manual for heatsink selection)
Input to Base-plate: 2kVAC; Input to Output 3.0kVAC for I min.; Output to Base-plate: 500VAC for 1 min
>100M at 25C and 70%RH, Output to Base plate 500VDC
Non Operating, 10-55Hz (sweep for 1 min.)
Amplitude 0.825mm constant (Max 49 m/s
2
) X,Y,Z 1 hour each
IEC61373 - Category 1, Grade B
-
196.1m/s
2
, IEC61373 - Category 1, Grade B
-
UL60950-1, CSA60950-1, EN60950-1
g
70g
in(mm)
1.45 x 0.5 x 2.28” (36.8 x 12.7 x 57.9)
yrs
5 Years
VDC
VDC
A
VDC
mV
mV
mV
%
%
-
-
°C
°C
%/°C
%RH
-
VAC
-
-
5V
Shock
(1)
Safety Agency Certifications
Weight (Typ)
Size (WxHxD)
Warranty
Note: See Installation Manual for full details, test methods of parameters and application notes
(1) Compliant to EN50155 & IEC60571