Data Sheet
24V Input Micro Family
DC-DC Converter Module
Features
•
DC input range: 18 - 36 V
•
Isolated output
•
Operation to 16 V at 75% power
•
•
•
•
•
•
•
•
•
•
•
after startup
Input surge withstand: 50 V for 100 ms
DC output: 3.3 – 48 V
Programmable output: 10 to 110%
Regulation: ±0.4% no load to full load
Efficiency: Up to 89%
Maximum operating temp: 100 °C, full load
Power density: up to 60 W per cubic inch
Height above board: 0.43 in. (10,9 mm)
Parallelable, with N+M fault tolerance
Low noise ZCS/ZVS architecture
RoHS Compliant (with F or G pin option)
Shown actual size:
2.28 x 1.45 x 0.5 in
57,9 x 36,8 x 12,7 mm
Absolute Maximum Ratings
Parameter
+In to -In voltage
PC to -In voltage
PR to -In voltage
SC to -Out voltage
Isolation voltage
in to out
in to base
out to base
Operating Temperature
Storage Temperature
Pin soldering temperature
Mounting torque
Rating
-0.5 to +53
-0.5 to +7.0
-0.5 to +7.0
-0.5 to +1.5
3000
1500
500
-55 to +100
-65 to +125
500 (260)
750 (390)
5 (0.57)
Unit
Vdc
Vdc
Vdc
Vdc
Vrms
Vrms
Vrms
°C
°C
°F (°C)
°F (°C)
in-lbs (N-m)
Test voltage
Test voltage
Test voltage
M-Grade
M-Grade
<5 sec; wave solder
<7 sec; hand solder
6 each
Notes
Product Overview
These DC-DC converter modules use
advanced power processing, control and
packaging technologies to provide the
performance, flexibility, reliability and cost
effectiveness of a mature power component.
High frequency ZCS/ZVS switching
provides high power density with low
noise and high efficiency.
Applications
Industrial and process control, distributed
power, medical, ATE, communications,
defense, aerospace
For details on proper operation please refer
to the
Design Guide & Applications Manual
for Maxi, Mini, Micro Family.
Part Numbering
e.g. V24C12T100BL2
V2 4 C
B
Output Power
Vout Pout
3.3 V
75
W,
50
W
125
W,
100
W,
50
W
5V
8V
100
W
12 V
150
W,
100
W,
50
W
15 V
150
W,
100
W,
50
W
24 V
150
W,
100
W,
50
W
28 V
150
W,
100
W,
50
W
36 V
100
W,
50
W
48 V
150
W,
100
W,
50
W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
Output Voltage
3 V 3
= 3.3 V
5
= 5V
8
= 8V
12
= 12 V
15
= 15 V
24
= 24 V
28
= 28 V
36
= 36 V
48
= 48 V
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
=
- 10 to +100
- 20 to +125
C
=
- 20 to +100
- 40 to +125
T
=
- 40 to +100
- 40 to +125
H
=
- 40 to +100
- 55 to +125
M
=
- 55 to +100
- 65 to +125
Vicor Corp.
Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
24V Micro Family
Rev. 5.0
Page 1 of 14
Set your site on VICOR at vicorpower.com
MODULE FAMILY ELECTRICAL CHARACTERISTICS
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature,
unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
14.8
36.3
17.5
15.3
37.8
39.6
4.0
Min
18
Typ
24
Max
36
50
17.9
Unit
Vdc
Vdc
Vdc
Vdc
Vdc
mA
PC pin low
Modules will operate to 16 Vin after startup at >17.9 V.
Below 18 V, available power is reduced to 75% of max
rating.
<100 ms
Notes
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.20
±0.005
±5
110
Unit
% Vout nom.
%
% / °C
%
%
Notes
Nominal input; full load; 25 °C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+Out to –Out — Absolute Maximum Ratings
3.3 V
5V
8V
12 V
15 V
24 V
28 V
36 V
48 V
-0.5 to 4.7
-0.5 to 7.0
-0.5 to 10.9
-0.5 to 16.1
-0.5 to 20.0
-0.5 to 31.7
-0.5 to 36.9
-0.5 to 47.1
-0.5 to 62.9
Note:
For important information relative to applications where the converter modules are subject to continuous dynamic loading,
contact Vicor applications engineering at 800-927-9474.
Thermal Resistance and Capacity
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20265)
Baseplate to ambient
Baseplate to ambient; 1000 LFM
Thermal capacity
Min
Typ
0.24
0.21
10.9
2.8
48
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
Vicor Corp.
Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
24V Micro Family
Rev. 5.0
Page 2 of 14
Set your site on VICOR at vicorpower.com
MODULE FAMILY ELECTRICAL CHARACTERISTICS (CONT.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
PRIMARY SIDE
(PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
SECONDARY SIDE
(SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
Vdc
Ω
µF
Vdc
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
Vdc
mA
Vdc
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25 °C
Minimum pulse width: 20 ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30
Ω,
< 30 pF
PC current = 1.0 mA
PC voltage = 5.5 V
Switch must be able to sink
≥4
mA. See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Isolation test voltage (in to out)*
Isolation test voltage (in to base)*
Isolation test voltage (out to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
Temperature limiting
Agency approvals
1.9
(52.8)
2.1
(58.7)
100
Min
3000
1500
500
10
2.1
(59.3)
2.3
(65.2)
115
cURus, cTÜVus, CE
2.3
(65.8)
2.5
(71.7)
Typ
Max
Unit
Vrms
Vrms
Vrms
MΩ
ounces
(grams)
ounces
(grams)
°C
See Figs. 3 and 5. Do not operate coverter >100 C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
in to out, in to baseplate, out to baseplate
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
Vicor Corp.
Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
24V Micro Family
Rev. 5.0
Page 3 of 14
Set your site on VICOR at vicorpower.com
MODULE SPECIFIC OPERATING SPECIFICATIONS
3.3 Vout, 75 W (e.g. V24C3V3C75BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
78
4.14
Typ
79
140
4.3
4
±0.02
26.1
26.1
Max
175
4.46
6
±0.4
22.72
30.7
30.7
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwidth
25 °C; recycle input voltage or PC to restart (>100 ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage < 250 mV
0
23.1
15.8
3.3 Vout, 50 W (e.g. V24C3V3C50BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
75
4.14
Typ
79.2
240
4.3
1.6
±0.02
17.5
17.5
Max
300
4.46
3
±0.2
15.15
20.6
20.6
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25 °C
p-p; Nominal input; full load; 20 MHz bandwidth
25 °C; recycle input voltage or PC to restart (>100 ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250 mV
0
15.5
10.6
5 Vout, 125 W (e.g. V24C5C125BL)
Safety Approvals Pending
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
80.2
6.0
Typ
84.3
150
6.25
4.3
±0.02
28.8
28.8
Max
188
6.5
5.3
±0.2
25.0
33.8
33.8
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input full load 25 °C
p-p Nominal input full load 20 MHz bandwidth
25 °C; recycle input voltage or PC to restart (>100 ms off)
No load
No load to full load nominal input
Output voltage 95% of nominal
Output voltage <250 mV
0.0
25.5
17.5
5 Vout, 100 W (e.g. V24C5C100BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83
6.03
Typ
84
100
6.25
3.2
±0.02
23
23
Max
125
6.47
4.8
±0.2
20
27
27
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25 °C
p-p; Nominal input; full load; 20 MHz bandwidth
25 °C; recycle input voltage or PC to restart (>100 ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage < 250 mV
0
20.4
2
5 Vout, 50 W (e.g. V24C5C50BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Vicor Corp.
Min
83
6.03
Typ
84.5
80
6.25
1.3
±0.02
11.5
11.5
Max
100
6.47
2.1
±0.2
10
13.5
13.5
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25 °C
p-p; Nominal input; full load; 20 MHz bandwidth
25 °C; recycle input voltage or PC to restart (>100 ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage < 250 mV
0
10.2
2
Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
24V Micro Family
Rev. 5.0
Page 4 of 14
Set your site on VICOR at vicorpower.com
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
8 Vout, 100 W (e.g. V24C8C100BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
84.3
9.36
Typ
86
145
9.7
3
±0.02
14.4
14.4
Max
182
10.1
3.4
±0.2
12.5
16.9
16.9
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25 °C
p-p; Nominal input; full load; 20 MHz bandwidth
25 °C; recycle input voltage or PC to restart (>100 ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250 mV
0
12.7
8.75
12 Vout, 150 W (e.g. V24C12C150BL)
Safety Approvals Pending
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
85.4
13.8
Typ
88.3
170
14.3
3.7
±0.02
14.4
14.4
Max
212
14.8
4.5
±0.2
12.5
16.9
16.9
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input full load 25 °C
p-p Nominal input full load 20 MHz bandwidth
25 °C; recycle input voltage or PC to restart (>100 ms off)
No load
No load to full load nominal input
Output voltage 95% of nominal
Output voltage <250 mV
0
12.8
8.8
12 Vout, 100 W (e.g. V24C12C100BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.8
13.7
Typ
85.8
209
14.3
4.4
±0.02
9.59
9.59
Max
262
14.9
6.1
±0.2
8.33
10.9
10.9
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25 °C
p-p; Nominal input; full load; 20 MHz bandwidth
25 °C; recycle input voltage or PC to restart (>100 ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage < 250 mV
0
8.5
1.09
12 Vout, 50 W (e.g. V24C12C50BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
87
13.7
Typ
88.1
80
14.3
1.8
±0.02
4.8
4.8
Max
100
14.9
2.6
±0.2
4.17
5.63
5.63
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25 °C
p-p; Nominal input; full load; 20 MHz bandwidth
25 °C; recycle input voltage or PC to restart (>100 ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage < 250mV
0
4.25
2.91
15 Vout, 150 W (e.g. V24C15C150BL)
Safety Approvals Pending
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Vicor Corp.
Min
86.0
17.1
Typ
89.0
152.0
17.8
3.9
±0.02
11.5
11.5
Max
190.0
18.4
5.0
±0.2
10.0
13.5
13.5
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input full load 25 °C
p-p Nominal input full load 20 MHz bandwidth
25 °C; recycle input voltage or PC to restart (>100 ms off)
No load
No load to full load nominal input
Output voltage 95% of nominal
Output voltage <250 mV
0.0
10.2
7.0
Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
24V Micro Family
Rev. 5.0
Page 5 of 14
Set your site on VICOR at vicorpower.com