EEWORLDEEWORLDEEWORLD

Part Number

Search

HC24-2.4-A+G

Description
AC/DC converter 24v 58w
Categorysemiconductor    Power management   
File Size69KB,2 Pages
ManufacturerSL Power
Environmental Compliance  
Download Datasheet View All

HC24-2.4-A+G Overview

AC/DC converter 24v 58w

SL POWER ELECTRONICS CORP.
6050 King Drive, Bldg. A
Ventura, CA 93003 + 805-486-4565
Internet: www.slpower.com
INTERNATIONAL + SERIES
INSTALLATION INSTRUCTIONS
RATINGS:
Input:
100/120/215/230-240 V ac, 50/60 Hz, Refer to chassis marking for input current ratings.
Output:
Model
Output Ratings at 25°C Ambient With Airflow Specified - See Notes
CP197-A+
F5-25/OVP-A+
F15-15-A+
F24-12-A+
F48-6-A+
G5-35/OVP-A+
HDBB105W-A+
HDCC150W-A+
HDD15-5-A+
HE12-10.2-A+
HE15-9-A+
HE2-18-A+
HE24-7.2-A+
HE28-6-A+
HE48-4-A+
HE5-18/OVP-A+
Notes:
1.
2
3.
4.
5.
6.
7.
8.
9.
10.
Airflow
35 cfm
14 cfm
35 cfm
35 cfm
35 cfm
35 cfm
26 cfm
35 cfm
14 cfm
14 cfm
14 cfm
14 cfm
14 cfm
14 cfm
14 cfm
14 cfm
Level
L5
L3M1
L5
L5
L1
L5
L3M1
L3M1
L3M1
L3M1
L3M1
L3M1
L3M1
L3M1
L1
L3M1
Notes
2,4,6
2,3
2,3,5
2,4,6
2,4,7
2,3,5
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3,8
2,3
5 V 50 A (derate to 44 A at 50 °C)
5 V 25 A
12 V 16 A or 15 V 15 A
24 V 12 A (derate to 10 A at 50 °C) or 28 V 10 A (derate to 8.6 A at 50 °C)
48 V 6 A (derate to 5 A at 50 °C)
5 V 35 A
5 V 12 A; +12 V 1.7 A or +15 V 1.5 A; -12 V 1.7 A or –15 V 1.5 A or –5 V 0.7 A
5 V 12 A; +12 V 3.4 A or +15 V 3 A; -12 V 3.4 A or –15 V 3 A or –5 V 1.5 A
±12 V 5 A or ±15 V 5 A
12 V 10.2 A
15 V 9 A
2 V 18 A
24 V 7.2 A
28 V 6 A
48 V 4 A
5 V 18 A
Models may be followed by suffix G to indicate compliance to RoHS.
Derate output current ratings 10 % for operation at 50 Hz.
No derating required for operation at 50 °C ambient unless specified otherwise above.
For operation at >25 °C to 50 °C, derate output linearly to value shown in table.
Output capable of exceeding 240 VA when overloaded.
Output rating exceeds 240 VA.
Output exceeds 240 VA and may exceed 60 V dc as a result of a component failure.
Output may exceed 60 V dc under certain conditions.
Maximum Relative Humidity 96 %, no condensation.
Storage: -40 °C to +80 °C. Units should be allowed to warm-up under non-condensing conditions before application of power.
SAFETY DECLARATION:
SL Power Electronics Corp. declares under our sole responsibility that all
models listed above are in conformity with the applicable requirements of EN 60950-1 following the provisions
of the Low Voltage Directive 73/23/EEC. All models are Certified to be in compliance with the applicable
requirements of UL 1950, CSA 22.2 No. 234 (see table for level), and EN 60950-1 for Pollution Degree 2
environment and Class I TN-S power systems. The output of some models poses an energy hazard or do not meet the
requirements for SELV. To identify these models, refer to the notes for the table above.
GROUNDING:
Protection Class I requires that the chassis be bonded to Protective Earth in the end application.
SPACINGS:
Creepage and clearance distances from primary circuits to ground and secondary circuits, as defined in the
applicable safety standards, must be maintained after installation to preserve the intended safety.
TEMPERATURES:
The maximum operating temperatures of certain safety components, as defined in the applicable safety
standards, must not be exceeded after installation to preserve the intended safety. The output power, ambient air temperature
and the availability, amount, direction and/or restriction of airflow influence the temperatures of these components.
WARNING! RISK OF FIRE!
All models require
external fusing to maintain the intended safety. Refer to
marking on chassis for maximum fuse ratings.
100 VAC
1
1
1
1
2
3
5
4
120 VAC
2
3
5
4
215 VAC
2
3
5
4
AC INPUT HOOKUP
INSTRUCTIONS
230-240
VAC
2
3
5
4
41-33496-0001 Rev. G 09/12/06 SHT 1 OF 2
Competition control competition materials and excellent works sharing
Control competition topics are a very important topic type in the National Undergraduate Electronic Design Competition, and they have appeared in every session in recent years. Most of the topics are ...
sigma Electronics Design Contest
NUCLEO_G431RB Review (1) Compilation Environment Settings
NUCLEO_G431RB Review (1) Compilation Environment SettingsI received the NUCLEO_G431RB development board, which looks basically the same as the traditional NUCLEO64.One of the highlights of NUCLEO_G431...
wenyangzeng stm32/stm8
Loto practical tips (1) Correctly and elegantly test power supply ripple
Loto practical tips (1) Correctly and elegantly test power supply ripple I find that the need to measure power supply ripple is becoming more and more common, not just for power supply engineers. Ripp...
LOTO2018 Power technology
EEWORLD University - Practical Application of IoT in Vehicles
Practical application of IoT in vehicles : https://training.eeworld.com.cn/course/27291Practical video tutorial on IoT in-vehicle applications...
JFET MCU
Schematic conversion
Has anyone converted AD---ORCAD? According to the online tutorials, it always fails. Can anyone help? Thank you very much...
曹伟1993 PCB Design
Come to TE Webinar Learning Center TE launches the first white paper "Connecting the Future of Mobility"
TE Webinar Learning Center Automotive Channel released the first white paper "Connecting the Future of Mobility"! As new trends and technologies bring new challenges to the design of automotive system...
EEWORLD社区 Integrated technical exchanges

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号