IE-iMcV-T1/E1/J1-
LineTerm SFP and 1x9
Operation Manual
FCC Radio Frequency Interference Statement
This equipment has been tested and found to comply with the limits for a Class A computing device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which the user will be required to correct the interference at his own expense.
Any changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
The use of non-shielded I/O cables may not guarantee compliance with FCC RFI limits. This digital apparatus does not exceed the Class
A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of
Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de
classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par le ministère des Communications du Canada.
Limited Lifetime Warranty
Effective for products of B&B Electronics shipped on or after May 1, 2013, B&B Electronics warrants that each such
product shall be free from defects in material and workmanship for its lifetime. This limited lifetime warranty is
applicable solely to the original user and is not transferable.
This warranty is expressly conditioned upon proper storage, installation, connection, operation and maintenance of
products in accordance with their written specifications.
Pursuant to the warranty, within the warranty period, B&B Electronics, at its option will:
1. Replace the product with a functional equivalent;
2. Repair the product; or
3. Provide a partial refund of purchase price based on a depreciated value.
Products of other manufacturers sold by B&B Electronics are not subject to any warranty or indemnity offered by
B&B Electronics, but may be subject to the warranties of the other manufacturers.
Notwithstanding the foregoing, under no circumstances shall B&B Electronics have any warranty obligations or any
other liability for: (i) any defects resulting from wear and tear, accident, improper use by the buyer or use by any
third party except in accordance with the written instructions or advice of the B&B Electronics or the manufacturer of
the products, including without limitation surge and overvoltage conditions that exceed specified ratings, (ii) any
products which have been adjusted, modified or repaired by any party other than B&B Electronics or (iii) any
descriptions, illustrations, figures as to performance, drawings and particulars of weights and dimensions contained
in the B&B Electronics’ catalogs, price lists, marketing materials or elsewhere since they are merely intended to
represent a general idea of the products and do not form part of this price quote and do not constitute a warranty
of any kind, whether express or implied, as to any of the B&B Electronics’ products.
THE REPAIR OR REPLACEMENT OF THE DEFECTIVE ITEMS IN ACCORDANCE WITH THE EXPRESS WARRANTY SET
FORTH ABOVE IS B&B ELECTRONIC’ SOLE OBLIGATION UNDER THIS WARRANTY. THE WARRANTY CONTAINED IN
THIS SECTION SHALL EXTEND TO THE ORIGINAL USER ONLY, IS IN LIEU OF ANY AND ALL OTHER WARRANTIES,
EXPRESS OR IMPLIED, AND ALL SUCH WARRANTIES AND INDEMNITIES ARE EXPRESSLY DISCLAIMED, INCLUDING
WITHOUT LIMITATION (I) THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND OF
MERCHANTABILITY AND (II) ANY WARRANTY THAT THE PRODUCTS ARE DO NOT INFRINGE OR VIOLATE THE
INTELLECTUAL PROPERTY RIGHTS OF ANY THIRD PARTY. IN NO EVENT SHALL B&B ELECTRONICS BE LIABLE FOR
LOSS OF BUSINESS, LOSS OF USE OR OF DATA INTERRUPTION OF BUSINESS, LOST PROFITS OR GOODWILL OR
OTHER SPECIAL, INCIDENTAL, EXEMPLARY OR CONSEQUENTIAL DAMAGES. B&B ELECTRONIC SHALL DISREGARD
AND NOT BE BOUND BY ANY REPRESENTATIONS, WARRANTIES OR INDEMNITIES MADE BY ANY OTHER PERSON,
INCLUDING WITHOUT LIMITATION EMPLOYEES, DISTRIBUTORS, RESELLERS OR DEALERS OF B&B ELECTRONIC
WHICH ARE INCONSISTENT WITH THE WARRANTY, SET FORTH ABOVE.
ii
Table of Contents
FCC Radio Frequency Interference Statement ............................................................... ii
Limited Lifetime Warranty....................................................................................................... ii
About the IE-iMcV-T1/E1/J1-LineTerm ............................................................................. 1
Installing an iMcV-Module ..................................................................................................... 2
Crossover/Straight-Through Connection ......................................................................... 2
Configuration ............................................................................................................................... 2
Prerequisites ................................................................................................................................. 3
Managed Modules ..................................................................................................................... 3
Configuration Control ............................................................................................................... 4
Unmanaged Modules ............................................................................................................... 5
DIP Switches ................................................................................................................................. 6
DIP Switch Settings (S2, S3).................................................................................................... 7
Features .......................................................................................................................................... 8
LED Operation ............................................................................................................................ 14
Loopback Testing .....................................................................................................................15
Pseudorandom Bit Sequence (PRBS) Testing ...............................................................16
Installation Troubleshooting ................................................................................................16
Specifications.............................................................................................................................. 18
B&B Electronics Technical Support ...................................................................................18
Fiber Optic Cleaning Guidelines .........................................................................................19
Electrostatic Discharge Precautions ..................................................................................20
Certifications ............................................................................................................................... 21
iii
About the IE-iMcV-T1/E1/J1-LineTerm, TP/SFP
NOTE
Unless noted otherwise, any reference is applicable for both the 1x9 and SFP version
of the
IE-iMcV-T1/E1/J1-LineTerm
in this manual.
IE-iMcV-T1/E1/J1-LineTerm, TP/SFP is an SNMP-Manageable module that
converts standard TDM-based copper transports (T1, E1, J1) to a single-mode or
multi-mode fiber signal. It performs a standard “Line Termination” function as
defined in GR-820-CORE. This function transmits an Alarm Indication Signal (AIS)
on the line whenever the received signal is lost. Line faults can easily be isolated
to one line section and do not propagate over multiple-line sections as they do
with normal line repeaters.
Each module includes one RJ-48 connector, one pair of ST or SC fiber optic
connectors or an SFP port, which can support any fiber type at 155Mbps; dual
strand available in LC connectors, and Single Strand Fiber SFPs available in SC
connectors. IE-iMcV-T1/E1/J1-LineTerm, TP/SFP modules install into any
modular, SNMP manageable iMediaChassis, as well as the MediaChassis series,
which is unmanaged. The IE-iMcV-T1/E1/J1-LineTerm, TP/SFP offers an extended
temperature range of -40°C to +85°C; when installed in an IE-MediaChassis/1 or
2, available in AC and DC, the module can be installed in challenging heat or
cold-related environments.
An IE-iMcV-T1/E1/J1-LineTerm, TP/SFP with SFP Module with Configuration
Control, configured as a Host, allows an SNMP Management Module in a
managed chassis to manage the Remote. All settings are enabled and enforced
through the SNMP. The Host keeps a copy of the Remote’s configuration
settings. Each module offers the feature Configuration Control; please refer to the
appropriate section.
When the Host unit is not in a managed chassis, the Host configures the Remote.
This ensures that the Remote’s configuration will not revert to its DIP Switch
settings and potentially disrupt traffic. However, if the user changes the DIP
Switch settings on the Remote, the new configuration of the Remote will be
enabled.
When SNMP management is installed at the Host, the following functions at the
Remote are controlled from the Host unit:
•
•
•
Loopback
Line Code
Transmit Data Source
1
•
Fault Loopback
The IE-iMcV-T1/E1/J1-LineTerm, TP/SFP with SFP Host unit can also display the
DDMI information from the Remote LineTerm module. Please download the
latest SNMP Management Module firmware and iVIew² software to ensure the
full support and functionality of the modules.
NOTE
IE-iMcV-T1/E1/J1-LineTerm, TP/SFP
with SFP Module can be installed in an
iMediaChassis and MediaChassis series.
Installing an iMcV-Module
iMcV-Modules install in B&B Electronics’ SNMP manageable iMediaChassis series
or in any MediaChassis/IE-MediaChassis series.
To install an iMcV-Module:
1.
2.
3.
4.
Remove the blank bracket covering the slot where the module is to be
installed by removing the screws on the outside edges of the bracket.
Slide the iMcV-Module into the chassis, via the cardguides, until the module
is seated securely in the connector.
Secure the module to the chassis by tightening the captive screw.
Save any “blanks” removed during installation for future use if the
configuration requirements change.
NOTE
All modules are hot-swappable
Crossover/Straight-Through Connection
IE-iMcV-T1/E1/J1-LineTerm, TP/SFP comes with an RJ-48 UTP connector that
features a push-button switch, located next to the port, for selecting a crossover
connection, push-button IN. A straight-through connection is selected when the
push-button is OUT. When unsure what type of connection is needed, set the
push button to the position that turns the LOS LED off.
Configuration
Proper configuration of the IE-iMcV-T1/E1/J1-LineTerm, TP/SFP is required for
maximum performance and reliability. The following sections describe the
prerequisites and the configurations available for both managed and unmanaged
modules.
2