LARGE ALUMINUM ELECTROLYTIC CAPACITORS
QA
Permissible Abnormal Voltage, Wide Temperature Range
Series
Improved safety features for abnormally excessive voltage
Ideally suited for the equipment used at voltage fluctuating area
No sparks with overvoltage
Complied to the RoHS directive
Item
Operating temperature range
Capacitance tolerance
Leakage current max.
Dissipation factor max.
Characteristics
-25 ~ +105 C
20% at 120Hz, 20 C
I=3 CV ( A) (after 5 minutes)
0.15 max. at 120Hz, 20 C
After an application of DC bias voltage plus the rated AC ripple current for 2000 hours at 105 C
The measurement shall meet the following limits.
Leakage current
Less than specified value
Capacitance change
Within 20% of initial value
tan
Less than 200% of specified value
After 1000 hours no load test, leakage current, capacitance and tan are same as load life value.
The measurement shall be performed at 20 C by the KS C 6503 clause 5.1.
The pressure relief vent will operate in normal conditions, with no dangerous conditions such as
flames, ignitions or dispersion of peaces of the capacitor and/or case
WV
μ
F
C < 300
330
C < 470
470
C
C < 100
100
C < 220
220
C
Limited DC current
4A
5A
7A
2A
4A
7A
Test voltage (VDC)
300 & 375
Load life
Shelf life (at 105°
C)
Safety Performance
200
400
500 & 600
DRAWING (See Page 178)
Unit : mm
DIMENSIONS & MAXIMUM PERMISSIBLE RIPPLE CURRENT
μ
F
WV
ØD
200
22
25.4
30
35
22
22
22
22
22
22
22
22
25.4
25.4
25.4
25.4
25.4
25.4
25
30
30
35
40
50
1.00
1.18
1.28
1.48
1.70
2.05
22
25
25
25
30
35
40
45
50
0.42
0.45
0.50
0.59
0.69
0.79
0.93
1.06
25.4
400
30
35
47
56
68
82
100
120
150
180
220
270
330
390
470
560
680
820
1000
1200
1500
22
22
22
22
22
22
22
25
25
30
30
35
40
40
0.74
0.82
0.97
1.07
1.24
1.43
1.63
25.4
25.4
25.4
25.4
25.4
25.4
25.4
25
25
30
30
35
40
45
0.55
0.60
0.71
0.78
0.92
1.06
1.22
30
30
30
30
30
30
30
25
25
30
30
35
40
50
0.73
0.80
0.95
1.04
1.21
1.40
1.68
30
30
30
30
30
30
30
25
25
25
35
40
45
50
1.21
1.31
1.44
1.76
2.03
2.33
2.68
35
35
35
35
35
35
25
30
35
40
45
50
1.70
1.98
2.29
2.65
2.80
3.25
Case size D L (mm)
Ripple current (A rms) at 105 C, 120Hz
35
35
35
35
35
35
35
25
25
30
35
40
45
50
0.97
1.06
1.24
1.44
1.67
1.89
2.15
FREQUENCY COEFFICIENT OF PERMISSIBLE RIPPLE CURRENT
WV
Frequency
160 ~ 250
300 ~
60Hz
0.85
0.85
120Hz
1.00
1.00
300Hz
1.20
1.15
1kHz
1.25
1.20
10kHz≦
1.45
1.40
180