EEWORLDEEWORLDEEWORLD

Part Number

Search

Z35092235609J6EC00

Description
Fixed Resistor, Wire Wound, 6W, 56ohm, 5% +/-Tol, -200,200ppm/Cel,
CategoryPassive components    The resistor   
File Size92KB,5 Pages
ManufacturerVishay
Websitehttp://www.vishay.com
Environmental Compliance
Download Datasheet Parametric View All

Z35092235609J6EC00 Overview

Fixed Resistor, Wire Wound, 6W, 56ohm, 5% +/-Tol, -200,200ppm/Cel,

Z35092235609J6EC00 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid989915897
Reach Compliance Codeunknown
ECCN codeEAR99
YTEOL7.1
structureCylindrical
Lead diameter0.8 mm
Number of terminals2
Maximum operating temperature250 °C
Minimum operating temperature-55 °C
Package diameter8.7 mm
Package length22.3 mm
Package shapeCYLINDRICAL PACKAGE
Package formAxial
method of packingAmmo Pack
Rated power dissipation(P)6 W
resistance56 Ω
Resistor typeFIXED RESISTOR
seriesZ300-C
technologyWIRE WOUND
Temperature Coefficient200 ppm/°C
Tolerance5%

Z35092235609J6EC00 Preview

Z300-C
www.vishay.com
Vishay Draloric
High Surge Axial Cemented Wirewound Resistors
FEATURES
• Standard version Z300-C00
• High voltage surge (up to 12 kV) for special
version
• Non flammable cement coating
• High grade ceramic core
• Material categorization: For definitions of
compliance please see
www.vishay.com/doc?99912
APPLICATIONS
• Energy meter
• Appliances
• Ballast
STANDARD ELECTRICAL SPECIFICATIONS
MODEL
POWER
RATING
P
40
W
1
2
3
4
5
6
POWER
RATING
P
70
W
0.9
1.8
2.5
3.5
4.7
5.4
RESISTANCE RANGE
TCR
(1)(2)
= ± 200 ppm/K
0.30 to 2K
0.47 to 4.3K
0.22 to 3.3K
0.47 to 3.9K
0.62 to 5.6K
0.15 to 10K
TOLERANCE
(3)
±%
10, 5
10, 5
10, 5
10, 5
10, 5
10, 5
Z301-C
ZDA0411-C
Z302-C
Z303-C
Z304-C
Z305-C
Notes
(1)
Lower TCR products are available on request
(2)
TCR of values <1R is ±400ppm/K
(3)
Resistance value to be selected for ± 10 % tolerance from E12 and for ± 5 % from E24, 1 % tolerance available on request.
Revision: 17-Aug-12
Document Number: 21027
1
For technical questions, contact:
ww1resistors@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
Z300-C
www.vishay.com
Vishay Draloric
PART NUMBER AND PRODUCT DESCRIPTION
Part Number: Z34081834700J6DC10
Z
3
4
0
8
1
8
3
4
7
0
0
J
6
D
C
1
0
MODEL
Z310309
= Z301-C
ZDA0411
=
ZDA0411-C
Z320414
= Z302-C
Z330617
= Z303-C
Z340818
= Z304-C
Z350922
= Z305-C
TCR/MATERIAL
1
= ± 100 ppm/K
3
= ± 200 ppm/K
4
= SWI
(special winding)
VALUE
3 digit value
1 digit multiplier
MULTIPLIER
7
= *10
-3
8
= *10
-2
9
= *10
-1
0
= *10
0
1
= *10
1
2
= *10
2
TOLERANCE
CODE
J
= ± 5.0 %
K
= ± 10.0 %
PACKAGING
CODE
(See
Packaging
Table)
SPECIAL
(1)
C00
= Standard
C04
= 4 kV surge
C06
= 6 kV surge
C08
= 8 kV surge
C10
= 10 kV surge
C12
= 12 kV surge
Product Description: Z304-C 3 470R 5 % AC G63 CD1278
Z304-C
3
470R
5%
TOLERANCE
CODE
AC G63
PACKAGING
DESCRIPTION
CD1278
Blank
= Standard
CDxxxx
= Speciality
MODEL
TCR/MATERIAL
VALUE
MINIMUM RESISTANCE VALUE FOR HANDLING SURGE VOLTAGE AS PER IEC61000-4-5
(1.2/50 μS PULSE)
POWER
1W
2W
3W
4W
5W
6W
TYPE
Z301-C
ZDA0411-C
Z302-C
Z303-C
Z304-C
Z305-C
4 kV SURGE
430R
180R
62R
27R
15R
4.7R
6 kV SURGE
1K5
510R
330R
91R
43R
18R
8 kV SURGE
-
1K1
680R
220R
82R
27R
10 kV SURGE
-
2K2
1K8
470R
100R
68R
12 kV SURGE
-
3K3
2K2
820R
330R
130R
Note
(1)
As surge handling capacity depends upon resistor model and ohmic value, please check feasibility of resistor model, ohmic value and
desired surge handling voltage with factory. (ww1resistors@vishay.com)
PACKAGING TABLE
AMMO PACK
MODEL
TAPE LENGTH (G)
(mm)
53
53
Z302-C
73
83
Z303-C
Z304-C
Z305-C
53
83
63
83
83
PIECES
1000
500
500
250
500
500
250
250
250
PACKAGING
CODE
21
2C
4C
6C
2C
6C
6D
6E
6E
PACKAGING
DESCRIPTION
A1 G53
AC G53
AC G73
AC G83
AC G53
AC G83
AC G63
AB G83
AB G83
Z301-C, ZDA0411-C
Revision: 17-Aug-12
Document Number: 21027
2
For technical questions, contact:
ww1resistors@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
Z300-C
www.vishay.com
DIMENSIONS
G
Vishay Draloric
B
A
X
C
DIMENSIONS
in millimeters (inches)
MODEL
A
MAX.
Z301-C
ZDA0411-C
Z302-C
Z303-C
Z304-C
Z305-C
8.5 (0.355)
11 (0.433)
13 (0.512)
15.8 (0.622)
18 (0.709)
22.3 (0.878)
B
MAX.
3 (0.118)
4 (0.157)
4.8 (0.189)
5.5 (0.217)
7.5 (0.295)
8.7 (0.343)
C
MAX.
0.7 (0.027)
0.7 (0.027)
0.8 (0.031)
0.8 (0.031)
0.8 (0.031)
0.8 (0.031)
G
53 ± 1 (2.087 ± 0.039)
53 ± 1 (2.087 ± 0.039)
53 ± 1 (2.087 ± 0.039)
73 ± 1 (2.87 ± 0.039)
83 ± 1 (3.268 ± 0.039)
53 ± 1 (2.087 ± 0.039)
83 ± 1 (3.268 ± 0.039)
63 ± 1 (2.48 ± 0.039)
83 ± 1 (3.268 ± 0.039)
X
MAX.
2 (0.079)
2 (0.079)
2 (0.079)
3 (0.118)
3 (0.118)
3 (0.118)
MASS
(g)
0.5
0.8
1.1
1.4
1.9
3.7
RATED POWER IN %
100
80
60
40
20
0
- 50
- 55
TEMPERATURE RISE IN K
120
300
ZDA0411-C
200
Z301-C
100
50
40
150
250
350
0
0
0.4
0.8
1.2
1.6
2.0
AMBIENT TEMPERATURE IN °C
Derating
POWER IN W
Temperature Rise
TEMPERATURE RISE IN K
TEMPERATURE RISE IN K
300
Z302-C
Z303-C
200
300
Z304-C
250
200
150
100
50
0
0
1
2
3
4
5
6
Z305-C
100
0
0
1
2
3
4
5
POWER IN W
Temperature Rise
POWER IN W
Temperature Rise
Revision: 17-Aug-12
Document Number: 21027
3
For technical questions, contact:
ww1resistors@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
Z300-C
www.vishay.com
HIGH VOLTAGE SURGE
The specially designed Z300-C high surge wirewound resistors are tested for surge handling capability by applying surge
voltage as per the 1.2 μs/50 μs exponential open circuit voltage waveform according to IEC 61000-4-5 standard as shown
below:
U
(% pulse voltage)
1.0
0.9
B
Vishay Draloric
0.5
0.3
0.1
0.0
O
1
A
T
2
T
T
1
30 % max.
{
t
Front time:
T
1
= 1.67 x T = 1.2 μs ± 30 %
Time to half-value: T
2
= 50 μs ± 20 %
Waveform of open-circuit voltage (1.2 μs/50 μs) at the output of pulse generator
PERFORMANCE
TEST
Climatic category (LCT/UCT/days)
Damp heat, steady state, IEC 60115-1, 4.24
(40 ± 2) °C, 56 days, (93 ± 3) % RH
Climatic sequence
IEC 60115-1 4.23
Endurance at room temperature (116 %
P
70
), 1000 h,
IEC 60115-1, 4.25.2
Endurance at UCT, 200 °C (30 %
P
70
), 1000 h,
IEC 60115-1, 4.25.3
Short time overload, IEC 60115-1, 4.13
10 x rated power
P
40
for 5 s
Resistance to soldering heat, IEC 60115-1, 4.18
(260 ± 5) °C, (10 ± 1) s
Robustness of termination, IEC 60115-1, 4.16
PERMISSIBLE CHANGE
40/200/56
R
= ± (3 %
R
+ 0.1
)
R
= ± (3 %
R
+ 0.1
)
R
= ± (3 %
R
+ 0.1
)
R
= ± (3 %
R
+ 0.1
)
R
= ± (2 %
R
+ 0.05
)
R
= ± (1 %
R
+ 0.05
)
R
= ± (0.5 %
R
+ 0.05
)
Revision: 17-Aug-12
Document Number: 21027
4
For technical questions, contact:
ww1resistors@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please
contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Material Category Policy
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the
definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council
of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(EEE) - recast, unless otherwise specified as non-compliant.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free
requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference
to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21
conform to JEDEC JS709A standards.
Revision: 02-Oct-12
1
Document Number: 91000
Summary: About 2.4G NRF24L01 wireless module
Through the study and practice of the 2.4G NRF24L01 wireless module and the reference to the Chinese and English manuals of NRF24L01, the following summary is made. If you want to have a deeper unders...
Aguilera RF/Wirelessly
After the holiday, I will give you a review~~
Hello~ Hello everyone~ The manager is here to send information again~~ Come and take a look at the latest situation~~New activities online:1. Anxinke Bluetooth Development Board PB-02-Kit Activities i...
okhxyyo Special Edition for Assessment Centres
DIY battery management + fully automatic electric fan
[i=s]This post was last edited by lanhua on 2022-8-30 13:22[/i]Fully automatic electric fanParticipate in the "Hands-on Learning about Power Supply Season 1: DIY small fan, fan all summer!" of "Electr...
lanhua Switching Power Supply Study Group
Capacitive sensor measurement system module circuit design precision amplifier circuit
[size=5]Precision amplifier circuit[/size] [size=5] [/size] [size=5]Convert 0~0.5mV voltage into 0~5V for A/D conversion. OP07 is used to form a two-stage integrated operational amplifier circuit. The...
Aguilera Analogue and Mixed Signal
【TI mmWave Radar Review】XWR14XX Data Path
[i=s]This post was last edited by a736015 on 2019-12-9 10:35[/i]IWR1443BOOST unboxing test: https://en.eeworld.com/bbs/thread-1101610-1-1.html SDK and example download: https://en.eeworld.com/bbs/thre...
a736015 TI Technology Forum
Disconnection detection
Disconnection detectionThe function of disconnection detection or no-load detection needs to be implementedThe implementation principle: By detecting the voltage drop of the input resistor of the char...
QWE4562009 Discrete Device

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号