IP Rating ............................................................ IP 40 .....................................................................IP 40
*RoHS Directive 2002/95/EC Jan 27 2003 including Annex
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
Model 91, 92, 93, 94 & 95 - 5/8 ” Square Single-Turn Panel Control
Mechanical Characteristics
1
Stop Strength (1/4 ” D shaft) .............................................................................................................................................45.19 N-cm (4 lb.-in.)
(1/8 ” D shaft) .............................................................................................................................................33.89 N-cm (3 lb.-in.)
Starting ........................................................................................................................................... 0.3 max. above average running torque
Running Torque
Single or Dual Section (A & R Bushings) .................................................................................................. 0.21 to 1.06 N-cm (0.3 to 1.5 oz.-in.)
Single or Dual Section (C & U Bushings) .................................................................................................. 0.14 to 1.06 N-cm (0.2 to 1.5 oz.-in.)
Mounting .............................................................................................................................................1.7-2.0 N-m (15-18 lb.-in.) maximum
Variation ...................................................................................................................... 0.35 N-cm (0.5 oz.-in.) maximum in 45 ° shaft travel
Weight (Single Section, Metal Bushing)...............................................................................................................................12.7 grams nominal
Terminals .................................................................................................................................Printed circuit terminals, J-Hooks or solder lugs
Soldering Condition ...........................................Recommended hand soldering using Sn95/Ag5 no clean solder, 0.025 ” wire diameter.
Maximum temperature 399 °C (750 °F) for 3 seconds. No wash process to be used with no clean flux.
Marking ..................................................................................Manufacturer’s trademark, date code, resistance, manufacturer’s part number
Ganging (Multiple Section Potentiometers).............................................................................................................................2 cups maximum
Hardware ...................One lockwasher and one mounting nut is shipped with each potentiometer, except where noted in the part number.
NOTE:
1
At
Performance specifications do not apply to units subjected to printed circuit board cleaning procedures.
room ambient: +25 °C nominal and 50 % relative humidity nominal, except as noted.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
Model 91, 92, 93, 94 & 95 - 5/8 ” Square Single-Turn Panel Control
Product Dimensions
Model 91 PC Pin Terminals, In-Line
22.86 ± 0.43
(.900 ± .017)
MOUNTING
SURFACE
12.70 ± .229
(.500 ± .009)
0.79 ± .025
(.031 ± .010)
DIA.
13.72 ± 0.38
(.540 ± .015)
1.37 ± 0.08
(.054 ± .003)
2.36 ± 0.08
(.093 ± .003)
15.88
(.625)
7.92
(.312)
Model 92 J-Hooked
Terminals, In-Line
.79
(.031) 2 PLCS.
3 2 1
SEE
HOW TO ORDER
CHART FOR
BUSHING OPTIONS.
10.16 ± 0.30
(.400 ± .012)
11.05 ± 0.20
(.435 ± .008)
SEE
NEXT PAGE
FOR SHAFT
OPTIONS.
2.54
(.100)
2.54
(.100)
1.19
(.047)
“A” STYLE
A.R. LUG
R
9.53
(.375)
15.29 ± 0.56
(.602 ± .022)
.254
(.010)
GAP
5.08
(.20)
1.52
(.06)
R2
R1
1
2
3
1
2
3
0.76 ± 0.05
(.030 ± .002)
TYP.
Model 94 J-Hooked
Terminals, "L" Pattern
Model 93 PC Pin Terminals, "L" Pattern
22.86 ± 0.43
(.900 ± .017)
MOUNTING
SURFACE
12.70 ± .229
(.500 ± .009)
0.79 ± .025
(.031 ± .010)
DIA.
13.72 ± 0.38
(.540 ± .015)
1.37 ± 0.08
(.054 ± .003)
2.36 ± 0.08
(.093 ± .003)
15.88
(.625)
7.92
(.312)
.81
(.032)
R. MAX.
5.33 ± .76
(.21 ± .03)
3.81
(.150)
MAX. TYP.
1.52
(.06)
GAP
3 2 1
SEE
HOW TO ORDER
CHART FOR
BUSHING OPTIONS.
DIA.
0.81
TYP.
(.032)
10.16 ± 0.30
(.400 ± .012)
R2
R1
5.08 ± 0.38
(.200 ± .015)
11.05 ± 0.20
(.435 ± .008)
SEE
NEXT PAGE
FOR SHAFT
OPTIONS.
1.19
(.047)
“A” STYLE
A.R. LUG
R
9.53
(.375)
12.70 ± 1.02
(.500 ± .040)
Shaft Flat Orientation
2.54
(.100)
2.54
(.100)
1
3
2
1
3
2
0.76 ± 0.05
(.030 ± .002)
TYP.
120 ° ± 5 ° STD.
FLAT ORIENTATION
(SHAFT AT CCW END)
1
CCW
2
POTENTIOMETER
3
Model 95 Solder Lug Terminals, "Triangular" Pattern
How are more than 10 billion transistors inside a chip realized?
Let’s watch a video first
The chip is constantly enlarged
It's like a huge city inside
How are more than 10 billion transistors inside ...
As a PCB design engineer with style, everyone must have known the layout and wiring rules of general PCB. However, are you also clear about the design rules of RF board PCB? Today, let's talk about t...
Internal functions: some special functions for the target CPU provided by the compiler, as well as commonly used functions that have been highly optimized through assembly.
The internal functions prov...
I got the msp432 board almost a year ago, and just started the LED lighting project:First of all, the clock module (CS) of msp432. Personally, I think the most distinctive feature of msp432 should be ...
Can INA282 sample AC voltage? I want to use it to sample AC, the frequency ranges from 100hz to 10khz, but the actual measurement is not 50 times magnification...
❈This article will discuss the signal integration and challenges faced by hardware engineers when designing or debugging connections running at speeds up to several Gb/s. Whether working on the next ...[Details]
The time that a transformer can operate normally for a long time under rated voltage and rated load is called the service life of the transformer. The materials used to make transformers are divide...[Details]
1. Background and measurement methods The DC-DC converter can be viewed as a simple feedback control system, as shown in Figure 1. Figure 1 A DC-DC converter can be abstracted as a feedback s...[Details]
A/D conversion technology
Today's software radio and digital image acquisition require high-speed A/D sampling to ensure effectiveness and accuracy. General measurement and control systems also hop...[Details]
This little thing is simple and fun, and can be used as a course design for beginners of microcontrollers.
Place your index finger gently on the sensor and you will see the LED indicator flashing w...[Details]
CATL achieved impressive performance in both revenue and market share in 2021, but cost pressure was still reflected in gross profit margin. On the evening of April 21, CATL disclosed its annual repo...[Details]
With the launch of a large number of new Snapdragon 8Gen1 products, a new round of Android phones are flooding the market. Lu Weibing, who is in charge of the general business of Redmi, said that t...[Details]
FLOW, a popular e-cigarette brand founded in January 2019, has been in arrears of wages for two months and there is still no solution. FLOW is a popular online celebrity e-cigarette brand in 2019,...[Details]
0 Introduction
With the rapid development of wireless communication services, the radio spectrum in the air is becoming more and more crowded, and the utilization rate of wireless spectrum is rec...[Details]
Editor's note: This is a case study article, which is a compilation of the research team's discussion on "dilemma reversal cases". The cases in the article are only used for research purposes and do ...[Details]
In my memory of entering society, cars have always been closely related to fuel and have a natural connection with oil. It seems that I have never doubted the eternity of this connection. However, wh...[Details]
Function of
the circuit
This is a digital display AD converter suitable for portable small measuring instruments. Because it uses liquid crystal display, the power consumption is s...[Details]
introduction Since the inverter transfer function is difficult to obtain and the voltage output often fluctuates, traditional pure PID control is difficult to achieve fast and stable response. The c...[Details]
Mitsubishi PLC FX3U series is a very popular small PLC with high performance, high reliability, ease of use, etc. In practical applications, remote I/O settings are one of the common requirements.
...[Details]