Connectivity....for
Business-Critical Continuity
Type N Connectors
Product Catalog
Type N Connectors
Connectivity....for
Business-Critical Continuity
Johnson
®
Type N Connectors
meet or exceed the performance requirements of MIL-PRF-39012. All
designs are based on 50 ohm system impedance per MIL-STD-348, and operate at frequencies up to
11 GHz minimum.
Applications
• Antennas
• Base stations
• Broadcast
• Cable assemblies
• Cellular
• Instrumentation
• Microwave Radio
• PCS
• Radar
• Radios
• RF and Microwave Components
• Satcom
• Surge Protection
• WLAN
Features
• All contacts are plated with 50 micro-inches of Gold for excellent durability and high
frequency performance
• Brass bodies are offered with Tri-alloy plating as the standard finish, and Gold where
soldering is required
• Coupling nuts are hex shaped to allow the connectors to be tightened to specified mating torque
• Plug interfaces and bulkhead jack bodies include gaskets for environmental sealing
• Precision grade in-series adapters have very low return loss performance to 18 GHz
• Cabled contacts are captivated upon assembly
• Flexible cable contacts can be crimped or soldered
• Semi-rigid cabled connectors are capable of operation to 18 GHz
• Semi-rigid cabled plug connectors are available in one piece versions, requiring solder
attachment only between the cable jacket and connector body
Table of Contents
PAGE
ASSEMBLY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . .13
ASSEMBLY TOOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
COMPETITOR CROSS REFERENCE . . . . . . . . . . . . . . . . . . .23
ELECTRICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . .3-4
ENVIRONMENTAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . .5
FLEXIBLE CABLE CONNECTORS . . . . . . . . . . . . . . . . . . . . . .8
IN-SERIES ADAPTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
JACK RECEPTACLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
MATERIAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . .5
MECHANICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . .5
MOUNTING HOLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
SEMI-RIGID CABLED CONNECTORS . . . . . . . . . . . . . . . . . .7
2
Connectivity....for
Business-Critical Continuity
Type N Connectors
ELECTRICAL SPECIFICATIONS
Impedance:
50 Ohms
Frequency Range:
Flexible Cabled and Receptacles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-11 GHz
Semi-Rigid Cabled and Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-18 GHz
VSWR:
(f = GHz)
Straight Flexible Cabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0-9 GHz
1.35 MAX
0-11 GHz
1.07+.01f
1.05+.01f
1.06+.01f
1.15+.02f
1.10+.02f
1.10+.02f
0-11 GHz
1.30 Max
9-11 GHz
1.50 Max
11-18 GHz
<1.25 Typical
<1.25 Typical
<1.25 Typical
<1.50 Typical
<1.50 Typical
<1.50 Typical
0-18 GHz
1.05+.01f
N/A
Right Angle Flexible Cabled. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RG-405 Semi-Rigid Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RG-402 Semi-Rigid Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RG-401 Semi-Rigid Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RG-405 Semi-Rigid Jacks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RG-402 Semi-Rigid Jacks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RG-401 Semi-Rigid Jacks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Un-cabled Receptacles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Insertion Loss:
(dB, tested at 9 GHz)
Straight Flexible Cabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.15 Max
Right Angle Flexible Cabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.30 Max
Semi-Rigid Cabled and Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.05 f (GHz)
Un-cabled Receptacles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A
Working Voltage:
(Vrms maximum)
Sea Level
RG-316, 316DS Cabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250
RG-58, 142, 405 Cabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 335
RG-402 Cabled. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500
RG-213, 214, 401, LMR-400 Cabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000
Un-cabled Receptacles and Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000
Dielectric Withstanding Voltage:
(Vrms minimum)
Sea Level
750
RG-316, 316DS Cabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RG-58, 142, 405 Cabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000
RG-402 Cabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1500
RG-213, 214, 401, LMR-400 Cabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2500
Un-cabled Receptacles and Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2500
Corona Level:
(Volts minimum)
70K Feet
RG-316, 316DS Cabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190
RG-58, 142, 405 Cabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250
RG-402 Cabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 375
RG-213, 214, 401, LMR-400 Cabled and Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500
Un-cabled Receptacles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A
70K Feet
65
85
125
250
250
3
Type N Connectors
Connectivity....for
Business-Critical Continuity
ELECTRICAL SPECIFICATIONS cont’d
RF High Potential Withstanding Voltage:
(Vrms minimum, tested at 4 and 7 MHz)
RG-316, 316DS Cabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500
RG-58, 142, 405 Cabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 670
RG-402 Cabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000
RG-213, 214, 401, LMR-400 Cabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1500
Un-cabled Receptacles and Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1500
Insulation Resistance:
5000 Megohms minimum
Contact Resistance:
(milliohms maximum)
Initial
Center Contact
Straight Cabled (non-captivated) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0
Straight Cabled (captivated) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5
Right Angle Cabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5
Un-cabled Receptacles and Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0
Outer Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.2
Braid to Body (Flexible Cabled Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.05
RF Leakage:
(dB minimum, tested at 2.5 GHz)
Cabled Connectors and Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -90
Un-cabled Receptacles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A
IMP3:
Typically <-90 dBm (tested per IEC Guidelines using 20W inputs swept over 1930-1990 MHz)
After Environmental
1.5
3.0
3.0
1.5
N/A
N/A
Type N In-Series Adapter Return Loss
138-4901-807
-10
138-4901-817
VSWR = 1.05+.01F
-20
-30
S11 (dB)
-40
-50
-60
0
3
6
9
Frequency (GHz)
12
15
18
4
Connectivity....for
Business-Critical Continuity
Type N Connectors
MECHANICAL SPECIFICATIONS
Engagement Design:
MIL-STD-348A, Series N
Durability:
500 Cycles minimum
Engagement/Disengagement Force:
6 inch-pounds maximum
Mating Torque:
7 to 10 inch-pounds
Bulkhead Mounting Nut Torque:
15 inch-pounds recommended
Coupling Proof Torque:
15 inch-pounds minimum
Coupling Nut Retention:
100 pounds minimum
Contact Retention:
(minimum - captivated contacts only)
Axial Force (lbs) Torque (in-oz)
Cabled Connectors and Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
N/A
4
Un-cabled Receptacles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Cable Retention: (minimum*)
Axial Force (lbs) Torque (in-oz)
RG-316 Cabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
N/A
RG-316DS Cabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
N/A
RG-58 Cabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
N/A
RG-142 Cabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
N/A
RG-213, 214 and LMR-400 Cabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
N/A
RG-405 Cabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
16
RG-402 Cabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
55
RG-401 Cabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
80
* Or cable breaking strength, whichever is less
ENVIRONMENTAL SPECIFICATIONS
(Meets or Exceeds the Applicable Paragraph of MIL-PRF-39012)
Temperature Range:
-65°C to +165°C
Thermal Shock:
MIL-STD-202, Method 107, Condition B (except +85°C high temperature)
Corrosion:
MIL-STD-202, Method 101, Condition B
Shock:
MIL-STD-202, Method 213, Condition I
Vibration:
MIL-STD-202, Method 204, Condition B
Moisture Resistance:
MIL-STD-202, Method 106
MATERIAL SPECIFICATIONS
Crimp - Brass per ASTM B16, Tri-Alloy (Cu/Sn/Zn) plated (.0001” min)
Solder - Brass per ASTM B16, Gold plated* per MIL-G-45204 (.00001” min)
Adapter - Brass per ASTM B16, Tri-Alloy (Cu/Sn/Zn) or Nickel per QQ-N-290 plated (.0001” min)
Contacts:
Male - Brass per ASTM B16, Gold plated* per MIL-G-45204 (.00005” min)
Female – Beryllium Copper per ASTM B196, Gold plated* per MIL-G-45204 (.00005” min)
Adapter – Beryllium Copper per ASTM B196, Gold plated* per MIL-G-45204 (.00005” min)
Insulators:
PTFE Fluorocarbon per ASTM D1710 and ASTM D1457
Gaskets:
Silicon Rubber per ZZ-R-765
Crimp Sleeves:
Copper per ASTM A75, Tri-Alloy (Cu/Sn/Zn) plated (.0001” min)
End Caps:
Brass per ASTM B16, Tri-Alloy (Cu/Sn/Zn) plated (.0001” min)
Nut Retention Spring (Plugs):
Beryllium Copper per ASTM B196, un-plated
Mounting Nut (Bulkhead Jacks):
Brass per ASTM B16, Nickel plated per QQ-N-290 (.0001” min)
Lock Washer (Bulkhead Jacks):
Steel, Zinc plated (.0001” min)
* All Gold plated parts include a .00005” minimum Nickel under plated barrier layer
Bodies:
5