Features .......................................................................................................................................................................................1
Ordering Information .....................................................................................................................................................................2
Dimensions and Patterns ― 3.2 x 2.5 mm .................................................................................................................................14
Dimensions and Patterns ― 5.0 x 3.2 mm .................................................................................................................................14
Dimensions and Patterns ― 7.0 x 5.0 mm .................................................................................................................................15
Additional Information .................................................................................................................................................................16
Revision History ..........................................................................................................................................................................17
Rev 1.07
Page 3 of 17
www.sitime.com
SiT3373
220 MHz to 725 MHz Ultra-low Jitter Differential VCXO
Electrical Characteristics
Table 2. Electrical Characteristics – Common to LVPECL, LVDS and HCSL
All Min and Max limits in the Electrical Characteristics tables are specified over temperature and rated operating voltage with standard
output termination shown in the termination diagrams. Typical values are at 25°C and nominal supply voltage.
Parameter
Output Frequency Range
Frequency Stability
Symbol
f
F_stab
Min.
220.000001
-15
-25
-35
-50
Operating Temperature Range
T_use
-20
-40
-40
-40
Supply Voltage
Vdd
2.97
2.70
2.52
2.25
Pull Range
Upper Control Voltage
Lower Control Voltage
Control Voltage Input Impedance
Control Voltage Input Bandwidth
Pull Range Linearity
Frequency Change Polarity
Input Voltage High
Input Voltage Low
Input Pull-up Impedance
Duty Cycle
Start-up Time
OE Enable/Disable Time
PR
VC_U
VC_L
VC_z
V_c
Lin
–
VIH
VIL
Z_in
DC
T_start
T_oe
70%
–
–
45
–
–
Typ.
–
–
–
–
–
–
–
–
–
3.30
3.00
2.80
2.50
Max.
725
+15
+25
+35
+50
+70
+85
+95
+105
Supply Voltage
3.63
3.30
3.08
2.75
V
V
V
V
ppm
Vdd
Vdd
MΩ
kHz
%
–
–
30%
-
55
3.0
3.8
Vdd
Vdd
kΩ
%
ms
µs
Measured from the time Vdd reaches its rated minimum value.
f = 322.265625 MHz. Measured from the time OE pin reaches
rated VIH and VIL to the time clock pins reach 90% of swing
and high-Z. See
Figure 9
and
Figure 10
Pin 2, OE
Pin 2, OE
Pin 2, OE logic high or logic low
Contact SiTime
for other input bandwidth options
See the APR (Absolute Pull Range)
Table 11.
Contact SiTime
for custom pull range options
Voltage at which maximum frequency deviation is guaranteed
Voltage at which minimum frequency deviation is guaranteed
Unit
MHz
ppm
ppm
ppm
ppm
°C
°C
°C
°C
Extended Industrial
Extended Commercial
Industrial
Condition
Accurate to 6 decimal places
Inclusive of initial tolerance, operating temperature, rated
power supply voltage, load variations, and first year aging
at 25°C, with VIN voltage at Vdd/2.
±15
ppm is only guaranteed for pull range up to
±100
ppm.
Frequency Range
Frequency Stability
Temperature Range
Voltage Control Characteristics
±25, ±50, ±80, ±100, ±150, ±200,
±400, ±800, ±1600, ±3200
90%
–
–
–
–
–
–
10
10
–
Positive Slope
–
–
100
–
–
–
–
10%
–
–
1.0
Input Characteristics
Output Characteristics
Startup and OE Timing
Rev 1.07
Page 4 of 17
www.sitime.com
SiT3373
220 MHz to 725 MHz Ultra-low Jitter Differential VCXO
Table 3. Electrical Characteristics – LVPECL Specific
Parameter
Current Consumption
OE Disable Supply Current
Output Disable Leakage Current
Maximum Output Current
Output High Voltage
Output Low Voltage
Output Differential Voltage Swing
Rise/Fall Time
RMS Period Jitter
[4]
RMS Phase Jitter (random)
Symbol
Idd
I_OE
I_leak
I_driver
VOH
VOL
V_Swing
Tr, Tf
T_jitt
T_phj
–
0.220
0.270
ps
Min.
–
–
–
–
Vdd-1.15
Vdd-1.9
1.2
–
–
Typ.
–
–
0.15
–
–
–
1.6
225
1.0
Max.
97
63
–
32
Vdd-0.7
Vdd-1.5
2.0
290
1.6
Unit
mA
mA
A
mA
V
V
V
ps
ps
Condition
Excluding Load Termination Current, Vdd = 3.3 V or 2.5 V
OE = Low
OE = Low
Maximum average current drawn from OUT+ or OUT-
See
Figure 5
See
Figure 5
See
Figure 6
20% to 80%, see
Figure 6
f = 322.265625 MHz, Vdd = 3.3 V or 2.5 V
f = 322.265625 MHz, Integration bandwidth = 12 kHz to 20 MHz,
all Vdd levels, includes spurs, pull range =
±100
ppm.
Temperature ranges -20 to 70°C and -40 to 85°C
f = 322.265625 MHz, Integration bandwidth = 12 kHz to 20 MHz,
all Vdd levels, includes spurs, pull range =
±100
ppm.
Temperature ranges -40 to 95°C and -40 to 105°C
f = 156.25 or 322.265625 MHz, IEEE802.3-2005 10 GbE jitter
mask integration bandwidth = 1.875 MHz to 20 MHz,
all Vdd levels
f = 322.265625 MHz, Vdd = 3.3 V or 2.5 V
f = 322.265625 MHz, Integration bandwidth = 12 kHz to 20 MHz,
all Vdd levels, includes spurs, pull range =
±100
ppm.
Temperature ranges -20 to 70°C and -40 to 85°C
f = 322.265625 MHz, Integration bandwidth = 12 kHz to 20 MHz,
all Vdd levels, includes spurs, pull range =
±100
ppm.
Temperature ranges -40 to 95°C and -40 to 105°C
f = 322.265625 MHz, IEEE802.3-2005 10 GbE jitter mask
integration bandwidth = 1.875 MHz to 20 MHz, all Vdd levels
Download the 5G infrastructure application of Nexperia and win prizes! The event has started~Click here to enter the eventNexperia in 5G InfrastructureThe key to power lies in power efficiency and rel...
This Electric Vehicle Service Equipment (EVSE) reference design adds Wi-Fi capabilities to J1772 Level 1 and Level 2 charging infrastructure. The CC3100 network processor enables highly embedded devic...
Click to enter the lucky flip event page, what are you waiting for, come and participate!Event time:February 8, 2022 - February 28, 2022Activity Rules1. New customers can enjoy one chance to flip the ...
1.4.17 Advanced Control Timer (Timer6)
Advanced Control Timer 6 (Timer6) is a high-performance timer with a 16-bit count width. It can be used to count and generate clock waveforms of different forms ...
In circuit design, when the input power is 12V or 24V, the power supply is 5V or 3.3V. We often encounter the problem of multiple power supplies.
A low-cost method is to use transformer regulation. On...
Although LEDs are point light sources like incandescent lamps, they have the advantages of being much smaller in size and radiating less heat for the same luminous flux. Under the global trend of gree...[Details]
The side-mounted magnetic flap level gauge consists of a body, a flap box, a float, a flange cover, etc., and is used to measure the liquid level of various liquid containers. It can be used in high...[Details]
1 Introduction
The performance of the instrument power supply will directly affect the work of the instrument. In order to ensure that the instrument can work normally in a complex environ...[Details]
On October 19, the Ministry of Industry and Information Technology issued the "Guiding Opinions on Further Strengthening the Construction of New Energy Vehicle Safety System" (draft for comments), wh...[Details]
3 Experimental Platform and Implementation of CoAP Protocol
3.1 Experimental Platform The hardware platform is the IPv6 intelligent gateway (MXG300), MX231CC node, USB wireless network card (STIC...[Details]
Abstract: Semiconductor laser (LD), as the light source for reading information from optical discs, is an important component of optical systems such as CD and DVD players/ROMs. Its performance ...[Details]
Performance requirements for control systems and tasks of this course
1.5.1 Requirements for control system performance
In order to achieve automatic control, certain requirem...[Details]
I. Introduction For the field of industrial automation, a large number of intelligent devices can be connected to the Internet through various channels, and information and data can be transmitted ...[Details]
In acid and alkali plants, the liquid level instruments are mainly used to measure the media of acid and alkali, and the instruments used mainly include anti-corrosion magnetic flap level gauges, u...[Details]
Times are always changing, the waves are flowing, and the sand is washed away by the waves.
When digital cameras matured, Kodak, which made camera film, was eliminated.
When smartphones m...[Details]
In recent years, with the overall acceleration of industrial automation construction, the requirements for network performance in the industrial control field are getting higher and higher. Under t...[Details]
(Photo source: PNNL official website) According to foreign media reports, scientists from the Pacific Northwest National Laboratory (PNNL) in the United States loaded a specially designed lithium-...[Details]
Mitsubishi PLC FX3U is a powerful small controller widely used in industrial automation. Its master control instructions are the core of program control. For programmers, it is very important to ma...[Details]