MACP-009011-C80370
E-Series 75 Ohm 8 dB Coupler
5 - 1200 MHz
Features
Coupling 8dB Typical
Surface Mount
Low Profile
Available on Tape and Reel
Excellent Temperature Stability
Rev. V3
Description
The MACP-009011-C80370 is a high performance
75 Ohm coupler, in a SM-55A low cost, surface
mount package.
The MACP-009011-C80370 is designed for use in
high volume CATV applications. Typical applications
include set-top boxes, network interface units,
broadband amplifiers and head-end equipment.
Functional Schematic
Ordering Information
Part Number
MACP-009011-C80370
MACP-009011-C803TB
Function
900 parts per reel
Customer test board
Pin Configuration
Pin No.
1
2
3
4
5
6
Function
Output
Not Connected
Isolation, external 75-Ohm
Coupled
Ground
Input
1
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit
www.macom.com
for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
MACP-009011-C80370
E-Series 75 Ohm 8 dB Coupler
5 - 1200 MHz
Electrical Specifications: Freq. = 5 - 1200 MHz, T
A
= 25°C, Z
0
= 75 Ω
Parameter
Mainline Loss
Coupling
Coupling flatness
Directivity
Return Loss Input
Return Loss Output
Return Loss Coupled
Test Conditions
5 - 870 MHz
870 - 1002 MHz
1002 - 1200 MHz
5 - 1002 MHz
1002 - 1200 MHz
5 - 1200 MHz
5 - 870 MHz
870 - 1200 MHz
5 - 50 MHz
50 - 1200MHz
5 - 50 MHz
50 - 870 MHz
870 - 1200 MHz
5 - 1200 MHz
Units
dB
dB
dB
dB
dB
dB
dB
Min.
2.0
2.3
2.6
8.5
8.7
—
—
—
—
—
Typ.
1.50
1.85
2.10
8.3
8.0
0.5
17.5
12.8
18.8
18.7
31.3
33.5
32.0
18.5
Max.
—
7.5
7.3
0.8
11
9
17.0
16.5
23
20
20
16
Rev. V3
Absolute Maximum Ratings
Parameter
RF Power
DC Current
Operating Temperature
Storage Temperature
Absolute Maximum
250 mW
30 mA
-20°C to + 85°C
-20°C to + 85°C
2
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit
www.macom.com
for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
MACP-009011-C80370
E-Series 75 Ohm 8 dB Coupler
5 - 1200 MHz
Typical Performance Curves: T
A
= 25°C, Z
0
= 75 Ω
Mainline
0.0
-0.5
-1.0
Rev. V3
Return Loss:
0
-5
-10
dB
5
244
483
722
961
1200
dB
-15
-20
-25
-1.5
-2.0
-2.5
-30
-35
5
244
483
722
961
1200
Frequency (MHz)
Frequency (MHz)
Coupling
-6
Return Loss: Output
0
-5
-7
-10
-8
dB
dB
-15
-20
-25
-30
-9
-1
0
5
244
483
722
961
1
200
-35
5
244
483
722
961
1200
Frequency (MHz)
Frequency (MHz)
Directivity
0
-5
-1
0
Return Loss: Coupling
0
-5
-1
0
dB
-20
-25
-30
-35
5
244
483
722
961
1
200
dB
-1
5
-1
5
-20
-25
-30
-35
5
244
483
722
961
1
200
Frequency (MHz)
3
Frequency (MHz)
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit
www.macom.com
for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
MACP-009011-C80370
E-Series 75 Ohm 8 dB Coupler
5 - 1200 MHz
Rev. V3
MACOM Technology Solutions Inc. All rights reserved.
Information in this document is provided in connection with MACOM Technology Solutions Inc ("MACOM")
products. These materials are provided by MACOM as a service to its customers and may be used for
informational purposes only. Except as provided in MACOM's Terms and Conditions of Sale for such products or
in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM
assumes no responsibility for errors or omissions in these materials. MACOM may make changes to
specifications and product descriptions at any time, without notice. MACOM makes no commitment to update
the information and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future
changes to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise,
to any intellectual property rights is granted by this document.
THESE MATERIALS ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR
IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR
WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR
INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR
OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY
OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN
THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS,
WHICH MAY RESULT FROM THE USE OF THESE MATERIALS.
MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM
customers using or selling MACOM products for use in such applications do so at their own risk and agree to
fully indemnify MACOM for any damages resulting from such improper use or sale.
5
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit
www.macom.com
for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support