Type SEK
105 ºC Radial Leaded Aluminum Electrolytic Capacitors
Long Life, Aluminum Electrolytic
Type SEK is a radial leaded aluminum electrolytic ca-
pacitor with a +105 º C, long life rating. The volumetic
efficient high CV product of the SEK makes it ideal for
high density packaging in general purpose, coupling,
decoupling, bypass and filtering circuit applications.
Highlights
•
•
•
•
•
Capacitance Range:
Voltage Range:
Capacitance Tolerance:
Operating Temperature Range:
Maximum DC Leakage Current:
+105 ºC
Long life
High CV product
General purpose applications
Available in T&R and ammo pack
Specifications
0.47 to 15,000 µF
6.3 to 450 Vdc
±20%
–55 ºC to +105 ºC; 6.3 to 100 Vdc
–40 ºC to +105 ºC; 160 to 400 Vdc
–25 ºC to +105 ºC; 450 Vdc
After 2 minutes, with rated voltage at +20 ºC
6.3 to 100 Vdc
I = .01CV or 3 µA Max (whichever is greater)
≥ 160 Vdc after 3 min, with rated voltage at +20 ºC
I = .03CV or 10 µA Max (whichever is greater)
C = Capacitance in (µF)
V = Rated voltage
I = Leakage current in µA
WV (V)
DF(%)
6.3 10 16 25 35 50 63 80 100 160-250 350-450
26 22 18 16 14 12 10 10 10
15
20
Dissipation Factor @ 120 Hz, +25 ºC:
Ripple Multipliers for Voltage and Temperature:
For capacitors whose capacitance value exceeds 1000 µF,
the value of DF (%) is increased 2% for every additional
1000 µF.
Rated
WVDC
6 to 25
35 to 100
160 to 250
350 to 400
Ambient
+105 ºC
+85 ºC
+70 ºC
Ripple Multipliers
60Hz
0.80
0.75
0.70
0.60
Ripple
1.00
1.50
1.80
120Hz
1.0
1.0
1.0
1.0
1kHz
1.1
1.3
1.4
1.5
10kHz
1.2
1.4
1.6
1.8
Temperature Multiplier
Load Life:
Apply WVDC for 2000 hours at +105 ºC
Capacitance change within 20% of initial limit
DF not to exceed 200% of initial requirement
Leakage current not to exceed 200% of initial
Complies with the EU Directive 2002/95/
EC requirement restricting the use of
Lead (Pb), Mercury (Hg), Cadmium (Cd),
Hexavalent chromium (Cr(VI)), PolyBro-
minated Biphenyls (PBB) and PolyBromi-
nated Diphenyl Ethers (PBDE).
Shelf Life:
1000 hrs with no voltage applied
Cap change within ±20% of initial values
DF not to exceed 200% of initial requirement
DC leakage current meets initial requirement
CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830 • www.cde.com
Type SEK
105 ºC Radial Leaded Aluminum Electrolytic Capacitors
Outline Drawing
Outline Dimensions
(Millimeters)
PVC Sleeve
d
0.05
S
0.5
+
+
-
L
15 Min.
5
D
Case vented on
diameters 6.3 and greater
Vinyl sleeve adds .5 Max. to diameter
and 2.0 Max. to length
Part Numbering System
Capacitance
Type
Capacitance Tolerance
(µF)
(%)
Rated
Voltage
(Vdc)
Packaging
Lead
Configuration
SEK
100
M
100
S
T
3R0 = 3
100 = 10
101 = 100
102 = 1000
K = ±10
M = ±20
6R3 = 6.3
010 = 10
100 = 100
A = Tape & Ammo
E = Different Characteristic
R = Tape & Reel
S = Standard
1 = Lead cut
2 = Lead form
4 = Lead crimp & cut (form)
T = Standard
Temperature Characteristics
200
100
20
10
%C
0
100F 25V
-10
-20
-40
0
40
80
Temperature
C
1
-40
0
40
80
Temperature
C
1F 50V
%DF
10
5
1F 50V
50
100F 25V
Capacitance Change Ratio
Dissipation Factor Change
Load Life Characteristics
100
10
%C
0
-10
-20
0
100F 160V
250
500
Time In Hours
750
1000
470F 25V
%DF 30
%LC
20
10
0
250
500
Time In Hours
470F 25V
100F 160V
750
1000
10
5
470F 25V
100F 160V
0
250
500
Time In Hours
750
1000
40
50
1
Capacitance Change Ratio
Dissipation Factor Change
Leakage Current Change
CDE Cornell Dubilier
•
1605 E. Rodney French Blvd.
•
New Bedford, MA 02744
•
Phone: (508)996-8561
•
Fax: (508)996-3830
•
www.cde.com