Type SCD IGBT Snubber Capacitor Modules
High dV/dt Direct Mount IGBT Snubber
Style SCD offers protection against voltage transients in low
to medium current IGBT applications where high dV/dt is
encountered. Connect these capacitors from C1 to E2 on a dual
IGBT module or from P to N on a six-pack module to eliminate
severe voltage transients. Parts ending with Z25 fit IGBTs with
23mm, 25mm and 28mm lead spacing. If you have a preferred
lead spacing, please specify.
Highlights
- High peak & RMS current capability
- Mount directly to the IGBT module
- Low inductance
- Low loss polypropylene dielectric
- Self healing
- Other terminal spacing and capacitance values available.
- We can build to your specs!
- 85 °C ambient temperature
0.22 to 4.7 µF
±10% (K) standard, ±5% (J) optional
600 to 2000 Vdc
-55 ºC to 85 ºC
Check tables for values
160% rated DC voltage for 60 s
3 kVac @ 50/60 Hz for 60 s
2000 h @ 85 ºC, 125% rated DC voltage
60,000 h @ rated Vdc, 70 ºC
30,000 h @ rated Vac, 70 ºC
RoHS Compliant
Specifications
Capacitance Range
Capacitance Tolerance
Rated Voltage
Operating Temperature Range
Maximum rms Current
Test Voltage between Terminals @ 25ºC
Test Voltage between Terminals & Case @ 25ºC
Life Test
Life Expectancy
Dimensions
L
Max
±1.0
W
Max
±1.0
Construction Details
Case Material
Resin Material
Terminal Material
Plastic UL94V-0
Dry Resin UL94V-0
Tin Plated Copper
H
±1.0
Max
5.0 mm
14.0 mm
±0.125
1.0 mm
±0.125
17.0 mm
17.3 mm
±0.125
6.5 x 8.5 mm
±0.125
Tolerances: ±0.5mm unless otherwise specified
7.0 mm
15.0
mm
14.0
mm
25.4 mm
CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830
Type SCD IGBT Snubber Capacitor Modules
High dV/dt Direct Mount IGBT Snubber
CDE Will Accommodate Your Bus Structure
Mounting Across the Bus?
Dual Snubber Assembly Option
Part Numbering System
SCD
105
K
122
A
3
-
25
–F
Series
Type
Designation
Capacitance
in pF
104 = 0.1 µF
105 = 1 µF
225 = 2.2 µF
Tolerance
Code
J = ±5%
Voltage
Internal
Type of
Lug
Lug Spacing
Assembly Section to be Configuration
Code
used
Z = Standard
25.4 mm C-C
22 = 22 mm
24 = 24 mm
25 = 25 mm
28 = 28 mm
29 = 29 mm
RoHS
Compliant
Indicator
601 = 600 Vdc
202 = 2000 Vdc
K = ±10% 122 = 1200 Vdc
CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830
Type SCD IGBT Snubber Capacitor Modules
High dV/dt Direct Mount IGBT Snubber
Note:
Other ratings, sizes and performance specification available upon request. Contact us.
Ratings
Irms
Catalog
Part Number
Cap.
(µF)
SCD474K601A3Z25-F
SCD684K601A3Z25-F
SCD105K601A3Z25-F
SCD155K601A3Z25-F
SCD205K601A3Z25-F
SCD335K601A3Z25-F
SCD475K601A3Z25-F
SCD474K102A3Z25-F
SCD474K102D3Z25-F
SCD684K102A3Z25-F
SCD684K102D3Z25-F
SCD105K102A3Z25-F
SCD105K102D3Z25-F
SCD155K102A3Z25-F
SCD155K102D3Z25-F
SCD205K102A3Z25-F
SCD205K102D3Z25-F
SCD224K122A3Z25-F
SCD334K122A3Z25-F
SCD474K122A3Z25-F
SCD684K122A3Z25-F
SCD105K122A3Z25-F
SCD155K122A3Z25-F
SCD205K122A3Z25-F
SCD305K122C3Z25-F
SCD224K162A3Z25-F
SCD334K162A3Z25-F
SCD474K162A3Z25-F
SCD684K162A3Z25-F
SCD105K162A3Z25-F
SCD155K162A3Z25-F
SCD205K162A3Z25-F
SCD224K202A3Z25-F
SCD334K202A3Z25-F
SCD474K202A3Z25-F
SCD684K202A3Z25-F
SCD105K202A3Z25-F
0.47
0.68
1.00
1.50
2.00
3.30
4.70
0.47
0.47
0.68
0.68
1.00
1.00
1.50
1.50
2.00
2.00
0.22
0.33
0.47
0.68
1.00
1.50
2.00
3.00
0.22
0.33
0.47
0.68
1.00
1.50
2.00
0.22
0.33
0.47
0.68
1.00
Volts
(Vdc )
600
600
600
600
600
600
600
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1200
1200
1200
1200
1200
1200
1200
1200
1600
1600
1600
1600
1600
1600
1600
2000
2000
2000
2000
2000
Volts
60 Hz
(Vac)
275
275
275
275
275
400
400
275
500
275
500
275
500
275
500
275
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
dV/dt
(V/µs)
600 Vdc
250
250
200
150
150
300
250
250
700
200
500
200
400
160
400
160
400
1200 Vdc
650
650
500
500
500
400
400
400
650
650
650
650
500
400
400
2000 Vdc
800
800
600
600
600
176
264
282
408
600
19
13
10
8
6
8.2
10.5
13.0
16.1
21.3
24.6
32.3
34.3
38.1
46.4
47.0
45.1
55.9
52.1
56.5
24.1
35.6
30.5
38.1
50.2
1600 Vdc
143
215
306
442
500
600
800
19
12
10
7
6
5
5
7.9
10.0
12.6
15.3
19.5
25.6
30.6
24.6
29.0
32.3
34.8
38.1
41.9
44.5
47.0
47.0
45.1
45.1
52.1
68.6
66.7
24.1
26.7
35.6
35.6
38.1
38.1
46.4
143
215
235
340
500
600
800
1200
19
13
10
7
5
4
4
5
7.9
10.0
12.0
15.1
18.5
23.9
30.1
39.7
24.6
29.0
29.0
32.3
34.8
38.1
46.4
76.2
47.0
47.0
47.0
45.1
45.1
52.1
56.5
62.9
24.1
26.7
26.7
35.6
35.6
38.1
50.2
38.1
1000 Vdc
118
329
136
340
200
400
240
600
320
800
11
8
7
7
4
5
4
3
4
5
9.2
12.1
11.5
14.4
14.0
17.5
17.9
22.4
20.9
26.2
24.6
29.0
29.0
29.0
29.0
29.0
32.3
34.8
34.8
38.1
47.0
47.0
47.0
47.0
47.0
47.0
45.1
45.1
45.1
52.1
24.1
26.7
26.7
26.7
26.7
26.7
35.6
35.6
35.6
38.1
118
170
200
225
300
825
1175
9
7
5
4
3
5
4
9.2
11.5
14.0
17.1
20.7
35.0
46.2
24.6
29.0
29.0
29.0
32.3
38.1
46.4
47.0
47.0
47.0
47.0
45.1
52.1
56.5
24.1
26.7
26.7
26.7
35.6
38.1
50.2
Ipk
(A)
ESR
(mΩ)
100 kHz
55 ºC
(Arms)
W
(mm)
L
(mm)
H
(mm)
Note: Modify Catalog Part Number to specify lead spacing. Example: 44mm spacing would use
–44
instead of Z25. Other capacitance values and lead orientations are
available. Contact us.
CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830
Notice and Disclaimer:
All product drawings, descriptions, specifications, statements, information and data
(collectively, the “Information”) in this datasheet or other publication are subject to change. The customer
is responsible for checking, confirming and verifying the extent to which the Information contained in this
datasheet or other publication is applicable to an order at the time the order is placed. All Information given
herein is believed to be accurate and reliable, but it is presented without any guarantee, warranty, representation
or responsibility of any kind, expressed or implied. Statements of suitability for certain applications are based
on the knowledge that the Cornell Dubilier company providing such statements (“Cornell Dubilier”) has
of operating conditions that such Cornell Dubilier company regards as typical for such applications, but
are not intended to constitute any guarantee, warranty or representation regarding any such matter – and
Cornell Dubilier specifically and expressly disclaims any guarantee, warranty or representation concerning
the suitability for a specific customer application, use, storage, transportation, or operating environment.
The Information is intended for use only by customers who have the requisite experience and capability to
determine the correct products for their application. Any technical advice inferred from this Information or
otherwise provided by Cornell Dubilier with reference to the use of any Cornell Dubilier products is given
gratis (unless otherwise specified by Cornell Dubilier), and Cornell Dubilier assumes no obligation or liability
for the advice given or results obtained. Although Cornell Dubilier strives to apply the most stringent quality
and safety standards regarding the design and manufacturing of its products, in light of the current state
of the art, isolated component failures may still occur. Accordingly, customer applications which require a
high degree of reliability or safety should employ suitable designs or other safeguards (such as installation
of protective circuitry or redundancies or other appropriate protective measures) in order to ensure that the
failure of an electrical component does not result in a risk of personal injury or property damage. Although
all product-related warnings, cautions and notes must be observed, the customer should not assume that all
safety measures are indicated in such warnings, cautions and notes, or that other safety measures may not be
required.