TECHNICAL DATA SHEET
QMA
STRAIGHT PLUG
28S107-307N3
All dimensions are in mm; tolerances according to ISO 2768 m-H
Interface
According to
Rosenberger 28S000-000, series QMA
Rosenberger is an authorised QLF manufacturer
Documents
Assembly instruction
28 D1
Material and plating
Connector parts
Center contact
Outer contact
Body
Dielectric
Unlocking sleeve
Crimping ferrule
Material
Brass
Spring bronze
Brass
PTFE
Brass
Copper
Plating
Gold, min. 1.27 µm, over chemical nickel
White bronze(e.g. Optalloy®)
Flash white bronze over silver(e.g. Optargen®)
Chemical nickel, 4 µm
Flash white bronze over silver(e.g. Optargen®)
RF_35/11.05/3.1
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel.: +49 8684 18-0
Fax: +49 8684 18-499
email: info@rosenberger.de
Page
1/2
TECHNICAL DATA SHEET
QMA
STRAIGHT PLUG
28S107-307N3
50
Ω
DC to 18 GHz
≥
29 dB, DC to 3 GHz
≥
25 dB, 3 to 4 GHz
≥
23 dB, 4 to 6 GHz
≤
0.05 x
f(GHz)
dB, DC to 6 GHz
≥
5 x10
3
MΩ
≤
3 mΩ
≤
2.5 mΩ
1000 V rms
480 V rms
≥
95 dB up to 2 GHz
≥
80 dB up to 4 GHz
≥
70 dB up to 6 GHz
Electrical data
Impedance
Frequency
Return loss
Insertion loss
Insulation resistance
Center contact resistance
Outer contact resistance
Test voltage, at sea level, 50Hz
Working voltage, at sea level, 50Hz
RF-leakage
- Limitations are possible due to the used cable type -
Mechanical data
Mating cycles
Center contact captivation: axial
Engagement force
Disengagement force
Retention force for interface
min. 100
≥
20 N
typ. 25 N
typ. 20 N
60 N min.
Environmental data
Temperature range
Storage temperature
Thermal shock
Corrosion
Vibration
Damp heat, steady state
-40°C to +85°C
-40°C to +85°C
IEC 60169-1 16.4 (-40 / +85°C)
IEC 60169-1 16.7 (48 hrs)
IEC 60068-2-64 random
IEC 60169-1 16.3 (96 hrs)
Tooling
Crimping tool
Crimp insert
11W150-000
11W150-108
Suitable cables
RG 142 B/U, RG 223 /U, RG 400 /U
Packing
Standard
Weight
100 pcs in bag
6.0 g/pce
While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our
products, we reserve the right to make changes judged to be necessary.
RF_35/11.05/3.1
Draft
Inge Mühlauer
Date
05/10/04
Approved
J. Krautenbacher
Date
11/01/06
Rev.
c00
Engineering change number
06-0015
Name
Rong Fang
Date
11/01/06
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel.: +49 8684 18-0
Fax: +49 8684 18-499
email: info@rosenberger.de
Page
2/2