EEWORLDEEWORLDEEWORLD

Part Number

Search

HLG-120H-48B

Description
led drivers power supplies 120w 48v 2.5A 90-305vac ip67 rated
CategoryLED optoelectronic/LED   
File Size305KB,6 Pages
ManufacturerMEAN WELL
Websitehttp://www.meanwell.com
Environmental Compliance
Download Datasheet Parametric View All

HLG-120H-48B Online Shopping

Suppliers Part Number Price MOQ In stock  
HLG-120H-48B - - View Buy Now

HLG-120H-48B Overview

led drivers power supplies 120w 48v 2.5A 90-305vac ip67 rated

HLG-120H-48B Parametric

Parameter NameAttribute value
ManufactureMean Well
Product CategoryLED Drivers Power Supplies
RoHSYes
Operation ModeConstant Current (CC)
Output Power Rating120 W
Input Voltage90 VAC to 305 VAC, 127 VDC to 431 VDC
Number of Outputs1
Output Voltage-Channel 148 VDC
Output Current-Channel 12.5 A
Mounting StyleChassis
Dimensions220 mm L x 68 mm W x 38.8 mm H
Commercial/MedicalCommercial
Open Frame/EnclosedEnclosed
ProducSwitching Supplies
Unit Weigh1.12 kg
120W Single Output Switching Power Supply
Features :
HLG-120H
series
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
High efficiency up to 93.5%
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potentiometer
IP67 / IP65 design for indoor or outdoor installations
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and street lighting applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
5 years warranty (Note.10)
F
110
M
M
SELV
IP65 IP67
HLG-120H-12 A
Blank : IP67 rated. Cable for I/O connection.
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance.
D (option, safety pending) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
SPECIFICATION
MODEL
DC VOLTAGE
HLG-120H-12
12V
CONSTANT CURRENT REGION
Note.4
6 ~12V
RATED CURRENT
10A
HLG-120H-15
15V
7.5 ~ 15V
8A
HLG-120H-20
20V
10 ~ 20V
6A
120W
150mVp-p
17 ~ 22V
HLG-120H-24
24V
12 ~ 24V
5A
120W
150mVp-p
22 ~ 27V
HLG-120H-30
30V
15 ~ 30V
4A
120W
200mVp-p
27 ~ 33V
2 ~ 4A
±1.0%
±0.5%
±0.5%
HLG-120H-36
36V
18 ~ 36V
3.4A
122.4W
200mVp-p
33 ~ 40V
1.7 ~ 3.4A
±1.0%
±0.5%
±0.5%
HLG-120H-42
42V
21 ~ 42V
2.9A
121.8W
200mVp-p
38 ~ 46V
1.4 ~ 2.9A
±1.0%
±0.5%
±0.5%
HLG-120H-48
48V
24 ~ 48V
2.5A
120W
200mVp-p
43 ~ 53V
1.2 ~ 2.5A
±1.0%
±0.5%
±0.5%
HLG-120H-54
54V
27 ~ 54V
2.3A
124.2W
200mVp-p
49 ~ 58V
1.1 ~ 2.3A
±1.0%
±0.5%
±0.5%
RATED POWER
120W
120W
RIPPLE & NOISE (max.)
Note.2
150mVp-p
150mVp-p
VOLTAGE ADJ. RANGE
Note.6
10.8 ~ 13.5V 13.5 ~ 17V
OUTPUT
CURRENT ADJ. RANGE
Can be adjusted by internal potentiometer A type only
5 ~ 10A
4 ~ 8A
3 ~ 6A
2.5 ~ 5A
VOLTAGE TOLERANCE
Note.3
±2.5%
±2.0%
±1.0%
±1.0%
±0.5%
±2.0%
±0.5%
±1.5%
±0.5%
±0.5%
±0.5%
±0.5%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
Note.8
1200ms,50ms/115VAC
500ms,50ms/230VAC at full load ; B type 1200ms,200ms/115VAC
500ms,200ms/230VAC at 95% load
12ms at full load
230VAC / 115VAC
127 ~ 431VDC
Note.5
90 ~ 305VAC
VOLTAGE RANGE
FREQUENCY RANGE
47 ~ 63Hz
INPUT
POWER FACTOR (Typ.)
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
TOTAL HARMONIC DISTORTION
THD< 20% when output loading
50% at 115VAC/230VAC input and output loading
75% at 277VAC input
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER CURRENT
SHORT CIRCUIT
93%
93%
92%
93%
1.4A / 115VAC
0.6A / 230VAC
0.55A / 277VAC
COLD START 60A(t
width
=375 s measured at 50% I
peak
) at 230VAC
μ
<0.75mA / 277VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Constant current limiting, recovers automatically after fault condition is removed
14 ~ 17V
18 ~ 21V
28 ~ 34V
34 ~ 38V
41 ~ 46V
47 ~ 53V
23 ~ 27V
Protection type :
Shut down o/p voltage with auto-recovery or re-power on to recovery
Shut down o/p voltage, recovers automatically after temperature goes down
-40 ~ +70
(Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80
, 10 ~ 95% RH
±0.03%/
(0 ~ 50
)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750, CSA C22.2 No. 250.0-08, ENEC, TUV EN61347-1, EN61347-2-13 independent IP65 or IP67, J61347-1,
J61347-2-13 approved ; design refer to UL60950-1, TUV EN60950-1
I/P-O/P:3.75KVAC
I/P-FG:2KVAC
O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
/ 70% RH
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C (
50% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
192.2K hrs min. MIL-HDBK-217F (25
)
220*68*38.8mm (L*W*H)
1.12Kg; 12pcs/14.4Kg/0.8CUFT
92%
93%
93%
93.5%
93.5%
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
54 ~ 63V
59 ~ 65V
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
Note.7
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to "DRIVING METHODS OF LED MODULE".
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. A type only.
7. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
10. Refer to warranty statement.
11. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号