New Product
Digital Temperature Controller (Simple Type)
E5CC-800/E5CC-B-800/E5CC-U-800
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to
Setup and Operation.
Models with Push-In Plus Terminal
Blocks Added to Lineup.
• The white PV display with a height of 15.2 mm improves
visibility.
• High-speed sampling at 50 ms.
• Select from models with screw terminal blocks, models with
Push-In Plus terminal blocks for reduced wiring work, and
Plug-in Models that can be removed from the terminal block.
• Short body with depth of only 60 mm. (Screw Terminal Blocks)
• Easy connections to a PLC with programless communications.
Use component communications to link Temperature
Controllers to each other.
48
×
48 mm
Screw Terminal
Blocks
E5CC-800
(48
×
48 mm)
*
(E5CC-800/-U-800) (E5CC-B-800)
* CSA conformance evaluation by UL.
48
×
48 mm
Push-In Plus
Terminal Blocks
E5CC-B-800
48
×
48 mm
Plug-in Models
E5CC-U-800
Refer to your OMRON website for the most recent information on
applicable safety standards.
Refer to Safety Precautions on page 58.
Main I/O Functions
Sensor Input
Universal input
•
Thermocouple
•
Pt
•
Analog current/voltage
Indication Accuracy
•
Thermocouple input:
<E5CC-800/E5CC-B-800>±0.3%PV
<E5CC-U-800>±1%PV
•
Pt input:
±0.2%
of PV
•
Analog input:
±0.2%
of FS
Sampling Period
•
50 ms
Serial Communications
<E5CC-800/E5CC-B-800> <E5CC-U-800>
•
None
•
None
•
RS-485
Event Inputs
<E5CC-800/E5CC-B-800>
•
None
•
2
E5CC-800/E5CC-B-800/E5CC-U-800
Dual displays: PV/SV
4-digit displays
•
PF (shift) Key
•
Temperature status display
•
Independent heating and
cooling PID control
•
Changed parameter display
Control Output 1
•
Relay output
•
Voltage output
(for driving SSR)
•
Linear current output
Auxiliary Outputs
•
2
<E5CC-U-800>
•
None
1
E5CC-800/E5CC-B-800/E5CC-U-800
Optional Products (Order Separately)
Terminal Covers (for E5CC-800)
Model
E53-COV17
E53-COV23 (3pcs)
Note:
The E53-COV10 cannot be used.
Refer to page 14 for the mounted dimensions.
Sockets (for E5CC-U-800)
Type
Front-connecting Socket
Front-connecting Socket with Finger Protection
Back-connecting Socket
Terminal Cover for Back-connecting socket
with Finger Protection
Model
P2CF-11
P2CF-11-E
P3GA-11
Y92A-48G
Waterproof Packing
Model
Y92S-P8
Note:
This Waterproof Packing is provided only with E5CC-800/
E5CC-B-800 Controllers.
The E5CC-U-800 cannot be waterproofed even if the
Waterproof Packing is attached.
Waterproof Cover
Model
Y92A-48N
Mounting Adapter
Model
Y92F-49
Note:
This Mounting Adapter is provided with the Digital Temperature
Controller.
Current Transformers (CTs)
Hole diameter
5.8 mm
5.8 mm
12.0 mm
12.0 mm
Model
E54-CT1
E54-CT1L *
E54-CT3
E54-CT3L *
Front Covers
Type
Hard Front Cover
Soft Front Cover
Model
Y92A-48H
Y92A-48D
* Lead wires are included with these CTs. If UL certification is
required, use these CTs.
Adapter
Model
Y92F-45
Note:
Use this Adapter when the panel has already been prepared for
an E5B@ Controller.
DIN Track Mounting Adapter (for E5CC-800)
Model
Y92F-52
3
E5CC-800/E5CC-B-800/E5CC-U-800
Specifications
Ratings
Power supply voltage
Operating voltage range
Power consumption
A in model number: 100 to 240 VAC, 50/60 Hz
D in model number: 24 VAC, 50/60 Hz; 24 VDC
85% to 110% of rated supply voltage
Models with option selection of 800: 5.2 VA max. at 100 to 240 VAC, and 3.1 VA max. at 24 VAC or
1.6 W max. at 24 VDC
All other models: 6.5 VA max. at 100 to 240 VAC, and 4.1 VA max. at 24 VAC or 2.3 W max. at 24 VDC
Temperature input
Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, or PL II
Platinum resistance thermometer: Pt100 or JPt100
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C
Analog input
Current input: 4 to 20 mA or 0 to 20 mA
Voltage input: 1 to 5 V, 0 to 5 V, 0 to 10 V,or 0 to 50 mV (The 0 to 50 mV range applies to the
E5CC-U-800 only for those manufactured in May 2014 or later.)
Current input: 150
Ω
max., Voltage input: 1 MΩ min.
(Use a 1:1 connection when connecting the ES2-HB-N/THB-N.)
ON/OFF control or 2-PID control (with auto-tuning)
E5CC-800/E5CC-B-800: SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, min-
imum applicable load: 5 V, 10 mA (reference value)
E5CC-U-800:
SPDT, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum
applicable load: 5 V, 10 mA (reference value)
Output voltage: 12 VDC
±20%
(PNP), max. load current: 21 mA, with short-circuit protection circuit
4 to 20 mA DC/0 to 20 mA DC, load: 500
Ω
max., resolution: approx. 10,000
2
SPST-NO relay outputs, 250 VAC, E5CC-800/E5CC-U-800 models with 2 output: 3 A (resistive load),
E5CC-B-800 models with 2 outputs: 2 A (resistive load)
Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V
2 (depends on model)
Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: Approx. 7 mA per contact
Digital setting using front panel keys
11-segment digital display and individual indicators
Character height: PV: 15.2 mm, SV: 7.1 mm
Up to eight set points (SP0 to SP7) can be saved and selected using event inputs, key operations, or
serial communications.
Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater
burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital
filter, self tuning, PV input shift, run/stop, protection functions, temperature status display, moving
average of input value
-10 to 55°C (with no condensation or icing)
25% to 85%
-25 to 65°C (with no condensation or icing)
2,000 m max.
T2A, 250 VAC, time lag, low-breaking capacity
Overvoltage category II, Pollution Degree 2 (EN/IEC/UL 61010-1)
Sensor input
Input impedance
Control method
Relay output
Control
output
Voltage output
(for driving SSR)
Linear current output *1
Number of outputs
Output specifications
Number of inputs
Event input
External contact input
*1*2
specifications
Setting method
Indication method
Multi SP
Auxiliary
output
Other functions
Ambient operating temperature
Ambient operating humidity
Storage temperature
Altitude
Recommended fuse
Installation environment
*1 There are no optional functions for the E5CC-U-800. Refer to
Model Number Legend
on page 2.
*2 There are no optional functions for the E5CC-B-800. Refer to
Model Number Legend
on page 2.
4
E5CC-800/E5CC-B-800/E5CC-U-800
Input Ranges (Universal inputs)
●Thermocouple/Platinum
Resistance Thermometer
Sensor
type
Sensor
specifica-
tion
2300
1800
1700
1600
1500
1400
1300
1300
1300
1300
1700
1700
Platinum resistance
thermometer
Pt100
JPt100
K
J
T
E
Thermocouple
L
U
N
R
S
B
C/W
2300
1800
Infrared temperature
sensor
PLII
10 to
70°C
60 to
120°C
115 to
165°C
140 to
260°C
Temperature range (°C)
1200
1100
1000
900
800
700
600
500
400
300
200
100
0
-100
-200
-200
-199.9
100.0
0.0
199.9
100.0
100
0.0
-20.0
-200
-100
-20.0
-200
-199.9
-200
-100
-200
-199.9
-200
0
0
0
0
0
0
0
0
90
500.0
500.0
500.0
400.0
400
400.0
400
400.0
260
120
165
600
850
850
850
Set value
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Shaded settings are the default settings.
The applicable standards for the input types are as follows:
K, J, T, E, N, R, S, B: JIS C 1602-2015, IEC 60584-1
L: Fe-CuNi, DIN 43710-1985
U: Cu-CuNi, DIN 43710-1985
C/W: W5Re/W26Re, JIS C 1602-2015, ASTM E988-1990
JPt100: JIS C 1604-1989, JIS C 1606-1989
Pt100: JIS C 1604-1997, IEC 60751
PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard)
●Analog
input
Input type
Input specification
Setting range
Set value
Current
4 to 20 mA
0 to 20 mA
1 to 5 V
Usable in the following ranges by scaling:
-1999 to 9999, -199.9 to 999.9,
-19.99 to 99.99 or -1.999 to 9.999
25
26
27
Voltage
0 to 5 V
0 to 10 V
0 to 50 mV *
28
29
30
* The range applies to the E5CC-U-800 only for those manufactured in May 2014 or later.