Frequency/Rate Meter
K3MA-F
CSM_K3MA-F_DS_E_7_1
Highly Visible LCD Display with 2-color (Red and
Green) LEDs
• Contact, NPN, PNP, or voltage pulse input.
• Front-panel key operation for easy setting.
• Average processing function suppresses flicker.
• Includes scaling, auto-zero time, startup compensation time functions.
• Easy confirmation of max/min display.
• Short 80-mm depth (measured from edge of face plate).
• Finger protective cover (standard equipment) guards against electric
shock.
• Water- and dust-proof NEMA4X (IP66 equivalent) front panel.
• Recognized to U.S. and Canadian requirements under the Compo-
nent Recognition Program of UL.
• CE marking.
• Built-in external power supply (12 VDC, 40 mA).
Refer to
Safety Precautions for All Digital Panel
Meters.
Model Number Structure
■
Model Number Legend
:
K3MA-F-@
1
2
3
3. Supply Voltage
100-240VAC: 100 to 240 VAC
24VAC/VDC: 24 VAC/VDC
1. Input Type
F:
Rotary pulse
2. Output Type
None: No output
A2: 2 relay contact outputs (SPST-NO)
Ordering Information
■
List of Models
Input type
Rotary pulse
Supply voltage
100 to 240 VAC
24 VAC/VDC
None
2 relay contact outputs (SPST-NO)
None
2 relay contact outputs (SPST-NO)
Output
Model
K3MA-F 100-240VAC
K3MA-F-A2 100-240VAC
K3MA-F 24VAC/VDC
K3MA-F-A2 24VAC/VDC
■
Rubber Packing
Model
K32-P1
Note:
Rubber packing is provided with the Controller.
■
Accessories (Order Separately)
Name
Splash-proof Soft Cover
Shape
K32-49SC
Model
Hard Cover
K32-49HC
1
K3MA-F
Specifications
■
Ratings
Model
Supply voltage
Operating voltage range
Power consumption
(under maximum load)
External power supply
Insulation resistance
Dielectric strength
Noise immunity
K3MA-F 100-240VDC, K3MA-F-A2 100-240VAC
100 to 240 VAC
85% to 110% of the rated supply voltage
6 VA max.
12 VDC, 40 mA
20 MΩ min. (at 500 VDC) between external terminal and case.
Insulation provided between inputs, outputs, and power supply.
2,000 VAC for 1 min between external terminal and case.
Insulation provided between inputs, outputs, and power supply.
±1,500
V on power supply terminals in normal or com-
±480
V on power supply terminals in normal mode.
mon mode.
±1,500
V in common mode.
±1 μs,
or 100 ns for square-wave noise with 1 ns.
±1 μs,
or 100 ns for square-wave noise with 1 ns.
Vibration: 10 to 55 Hz, Acceleration: 50 m/s
2
5 min each in X, Y, and Z directions for 10 sweeps.
150 m/s
2
(100 m/s
2
for relay contact outputs) 3 times each on 3 axes, 6 directions.
Operating:
−10°C
to 55°C (with no condensation or icing)
Storage:
−25°C
to 65°C (with no condensation or icing)
UL61010-1, conforms to EN61010-1 (IEC61010-1) (Pollution degree 2/overvoltage category II)
Conforms to VDE0106/P100 (finger protection)
EN61326+A1 Industry
CISPR 11 Group 1 class A: CISRP16-1/-2
CISPR 11 Group 1 class A: CISRP16-1/-2
EN61326+A1 Industry
EN61000-4-2: 4 kV contact discharge
8 kV air discharge
Immunity RF-interference:
EN61000-4-3: 10 V/m (amplitude-modulated, 80 MHz to 1 GHz)
Electrical Fast Transient Noise:
EN61000-4-4: 2 kV (power line)
Immunity Burst Noise:
1 kV line to line (I/O signal line)
Immunity Surge:
EN61000-4-5: 1 kV (power line)
2 kV line to ground (power line)
Immunity Conducted Disturbance: EN61000-4-6: 3 V (0.15 to 80 MHz)
Immunity Voltage Dip/Interrupting: EN61000-4-11: 0.5 cycle, 0, 180°, 100% (rated voltage)
Approx. 200 g
(EMI)
Emission Enclosure:
Emission AC Mains:
(EMS)
Immunity ESD:
4.5 VA max. (24 VAC)
4.5 W max. (24 VDC)
K3MA-F 24VAC/VDC, K3MA-F-A2 24VAC/VDC
24 VAC/VDC
Vibration resistance
Shock resistance
Ambient temperature
Approved safety standards
EMC
Weight
2
K3MA-F
■
Characteristics
Input signal
No-voltage contact (30 Hz max., ON/OFF pulse width: 15 ms min.)
Voltage pulse (5 kHz max., ON/OFF pulse width: 90
µs
min., ON voltage: 4.5 to 30 V/OFF voltage:
0 to 2 V)
Open collector (5 kHz max., ON/OFF pulse width 90
µs
min.)
Connectable Sensors
ON residual voltage:
2.5 V max.
OFF leakage current: 0.1 mA max.
Load current:
Must have switching capacity of 15 mA min.
Must be able to dependably switch a load current of 5 mA max.
±0.1%FS ±1
digit (at 23±5°C)
Cycle measurement
5 digits (−19999 to 99999)
7-segment digital display, Character height: 14.2 mm
“−” is displayed automatically with a negative input signal.
Leading zeros are not displayed.
Programmable with front-panel key inputs (range of display:
−19999
to 99999).
The decimal point position can be set as desired.
Max hold (maximum value), Min hold (minimum value)
Programmable with front-panel key inputs (0001 to 9999).
Scaling teach function
Display color change (green (red), green, red (green), red)
OUT type change (upper limit, lower limit, upper/lower limit)
Average processing (simple average OFF/2/4/8 operations)
Auto-zero time
Startup compensation time
Setting change lockout
Parameter initialization
Display auto-return time
Relays: 2 SPST-NO
750 ms max.
Front panel: NEMA4X for indoor use (equivalent to IP66)
Rear case: IEC standard IP20
Terminals: IEC standard IP00 + finger protection (VDE0106/100)
Non-volatile memory (EEPROM) (possible to rewrite 100,000 times)
Measuring accuracy
Measurement method
Max. displayed digits
Display
Polarity display
Zero display
Scaling function
Hold function
Hysteresis setting
Other functions
Output
Delay in comparative outputs
Degree of protection
Memory protection
■
Measuring Ranges
No-voltage Contact/Open Collector Inputs
Input
No-voltage contact (30 Hz max.) with
ON/OFF pulse width of 15 ms min.
Open collector (5 kHz max.) with
ON/OFF pulse width of 90
µs
min.
Measuring range
0.05 to 30.00 Hz
0 to 5 kHz
Measuring accuracy
±0.1%
FS
±1
digit max.
(at 23±5°C)
Displayable range
–19999 to 99999
(with scaling function)
■
Input/Output Ratings
Relay Contact Output
Item
Rated load (UL ratings)
Rated carry current
Max. contact voltage
Max. contact current
Max. switching capacity
Min. permissible load
(P level, reference value)
Mechanical life
Electrical life
(at an ambient temperature of 20°C)
Resistive load (cosφ = 1)
5 A at 250 VAC, 5 A at 30 VDC
5 A max. (at COM terminal)
250 VAC, 150 VDC
5 A (at COM terminal)
1,250 VA, 150 W
10 mA at 5 VDC
5,000,000 times min. (at a switching frequency of 1,200 times/min)
100,000 times min. (at a rated load switching frequency of 10 times/min)
250 VA, 30 W
Inductive load (cosφ = 0.4, L/R = 7 ms)
1 A at 250 VAC, 1 A at 30 VDC
3
K3MA-F
Connections
■
Terminal Arrangement
Power
supply
A1
Output
terminals
100- to 240-VAC type or
24-VAC/VDC type
Input
terminals
(No polarity for 24-VDC
connection.)
Models with
comparative
output
OUT1
OUT2
E1
E2
E3
E4
A2
+
12 V
40 mA
B5
B6
E5
E6
External power supply
−
Note:
Refer to
Input Circuits
on page 5.
Terminal No.
A1
-
A2
E4 , E6
-
E5
E1 , E2
-
E3
B5
-
B6
Name
Operation power
Pulse input
Outputs
External power supply
Description
Connects the operation power supply.
No-voltage contact/open collector input
Outputs the relay outputs.
Use as the power supply for sensors.
■
Block Diagram
Input
Input circuit
Micro-
computer
EEP ROM
Key
Display
Output
circuit
Contact output
(See note.)
X
5V
12 V
Constant voltage circuit
Power supply circuit
Note:
Relay output models only.
■
Input Circuits
Pulse Input
12 V
200
Ω
1 kΩ
E4
NPN, contact input
NPN
Pulse
detection
circuit
E5
12 V
Voltage
detection
circuit
10 kΩ
PNP, voltage pulse input
Voltage pulse
PNP
E6
+
−
B5
B6
The negative pole of the sensor power
supply and COM are connected
internally.
4
K3MA-F
Operation
■
Main Functions
Input Types and Ranges
Frequency range
(setting parameter)
Pulse frequency selection
(p-fre)
Function
Selects pulse input signal.
Input range (setting parameters)
0.05 to 30.00 Hz
0 to 5 kHz
(30)
(5k)
Setting range
Displayable from
−19999
to 99999
with scaling function.
The position of the decimal point
can be set as desired.
Pulse Frequency Selection
Parameter
p-fre
30
5k
Note:
The default value is “0 to 5 kHz (5k).”
Setting value
Meaning
0.05 to 30.00 Hz
measurement range
0 to 5 kHz measure-
ment range
Scaling
When the desired display value is set for a corresponding input, the value will be displayed on a line between two points determining the zero point.
Parameter
inp
dsp
Setting value
0
to
99999
-19999
to
99999
Meaning
Input value for
dsp
Display value for
inp
Parameter
dp
Setting value
%.%%%%
%%.%%%
%%%.%%
%%%%.%
%%%%%
Note:
Display value
DISPLAY
Meaning
Display four digits after decimal point
Display three digits after decimal point
Display two digits after decimal point
Display one digit after decimal point
No decimal point
The initial value will change depending on the
pulse frequency selection.
The decimal point can be optionally displayed.
When displaying the decimal point, consider the
number of digits to follow the decimal point prior to
setting the scaling display value.
If
p-fre
is set to 30, the initial setting for the
decimal display will be
000.00.
INPUT
Input value
Teaching with actual values is possible.
Instead of setting by inputting with the
Up Key and
Shift Key, current values can be
input as scaling input values for teaching. This is useful for making settings while checking the
operation status of the K3MA-F.
5