MPO-20S
Series
Single Output, 20W
Compact, Open Frame
AC/DC Power Supplies
Electrical Specifications
Key Features:
•
20W Output Power
•
Universal 85-264 AC Input
•
EN 60950 Approved (UL)
•
Compact 2 x 3.5 In Package
•
Six Standard Models
•
Meets EN 55022 B
•
Meets EN 61000-4
•
>200 kHour MTBF
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Input Frequency
Input Filter
Input Current
Inrush Current
Safety Ground Leakage Current
Conditions
Min.
Typ.
Max.
Universal
85
264
127
373
47
63
Meets EN 55022 Class B; FCC Class B
See Model Selection Guide
Cold Start, 115 VAC
20.0
40.0
Cold Start, 230 VAC
264 VAC
3.5
Max.
Units
VAC
VDC
Hz
A Pk
mA
Units
%
%
%
%
mSec
%/°C
%
Output
Parameter
Output Voltage/Current
Output Voltage Tolerance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Hold-Up Time
Temperature Coefficient
Short Circuit Protection
Overload Protection
Conditions
Min.
Typ.
See Model Selection Guide
See Note 1
±1.0
Vin = 100 VAC to 240 VAC
±0.5
Iout = 10% to 100%
±1.0
See Note 2
±1.0
115 VAC
16
230 VAC
85
±0.05
Hiccup Mode (Autorecovery)
150
Conditions
Input to Output
500 VDC
Conducted
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
Fixed
Conditions
Min.
3,000
Typ.
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
EMI/RFI
Units
VAC
1,000
M
220
pF
EN 55022; EN 61000-3-2, -3
IEC/EN 61000-4-2, -6, -8, -11
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
67
kHz
Units
°C
°C
%
Max.
EMC Compliance
Switching Frequency
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Size
Weight
Min.
Typ.
Max.
0
+25
+40
-20
+85
Free Air Convection (See Derating Curve)
RH, Non-condensing
93
Ambient
3.50 x 2.00 x 0.906 Inches (88.92 x 50.08 x 23.00 mm)
3.52 Oz (0.100 kg)
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 25°C, Gnd Benign
200
kHours
UL 60950, EN 60950
Sinusoidal 5~500 Hz, 3.0 Grms, Period of 30 min each along X, Y & Z Axis
Reliability Specifications
Parameter
MTBF
Safety Standards
Vibration
www.micropowerdirect.com
Model Selection Guide
Model
Number
MPO-20S-03
MPO-20S-05
MPO-20S-09
MPO-20S-12
MPO-20S-15
MPO-20S-24
Input
Current
(A)
115
VAC
0.44
0.44
0.44
0.44
0.44
0.44
230
VAC
0.24
0.24
0.24
0.24
0.24
0.24
Voltage
(VDC)
www.micropowerdirect.com
Output
Current
(A)
Rated
4.40
4.40
2.45
1.80
1.40
0.92
% Min.
0.00
0.00
0.00
0.00
0.00
0.00
Max
Output
Power
(W)
Max
Output
Capacitance
(µF)
Efficiency
(%, Typ)
3.3
5.0
9.0
12.0
15.0
24.0
14.5
22.0
22.0
22.0
22.0
22.0
4,400
4,400
2,530
2,200
1,400
950
68
75
79
81
83
83
Other Models May Be Available. Contact The Factory For Details
Notes:
1. Output voltage tolerance is measured at nominal input and 75% load.
2. Output ripple is measured at 20 MHz bandwidth using 0.1
µF
and 10
µF
capacitors connected in parallel as close to the power supply terminals
as possible.
3. These units will operate at no load without damage. For most appli-
cations however,
MPD
recommends that a minimum load always be
used. Contact the factory for more information.
4. Each unit includes an input fuse (250V/2A). Since this fuse is not field
replaceable, it is recommended that an external fuse of the same size
be used on the input of the power supply for protection.
Derating Curve
Mechanical Dimensions
Connections
Input Connector (CN1):
•
Molex 5273-03A or equivalent (one pin removed)
•
Mating Housing: Molex 5195-03 or equivalent
•
Mating Terminal: Molex 5293 or equivalent
Pin
1
2
3
Safety Ground:
The mounting holes marked “Use metal standoffs” should be
connected to the system earth ground via metal spacers or
a cable. The input side mounting hole marked “FG” provides
the safety earth ground for the unit. This connection should
be locked to prevent possible loosening. Connecting the
output side mounting hole improves EMI.
Function
AC-Neutral
Removed
AC-Line
Output Connector (CN2):
•
Molex 5273-04A or equivalent
•
Mating Housing: Molex 5195-04 or equivalent
•
Mating Terminal: Molex 5293 or equivalent
Pin
1
2
3
4
Function
+V
OUT
+V
OUT
-V
OUT
-V
OUT
Notes:
•
All dimensions are typical in inches (mm)
•
Tolerance x.xx =
±
0.02 (
±
0.50)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com