19 (decimal code, with component-adding provision)
54 (binary coded hexadecimal)
55 (binary coded hexadecimal, with
component-adding provision) *3
Model
Light gray
A7BS-206 *2
A7BS-207 *2
A7BS-219
A7BS-254
A7BS-255
Solder terminals *1
Black
Light gray
Model
A7BS-206-1 *2
A7BS-206-S
A7BS-207-1 *2
A7BS-219-1
A7BS-254-1
A7BS-255-1
A7BS-207-S
---
---
---
Black
A7BS-206-S-1
A7BS-207-S-1
---
---
---
A7BL
Snap-in (front mounting)
Classification
(See note 1.)
Locking type
Terminals
Color
Output code number
06 (binary coded decimal)
07 (binary coded decimal, with component-
adding provision) *3
Solder terminals *1
Light gray
Black
Model
A7BL-206 *2
A7BL-206-1 *2
A7BL-207 *2
A7BL-207-1 *2
Note: 1. The classification diagrams show 4 Switch Units combined with End Caps to create 4-digit displays.
2. The model numbers given above are for Switch Units.
3. Models with +, - displays can also be produced. Add "-PM" (+/- alternating display) or "-MP" (-/+ alternating display) after the "206" or "207" in the model number
(e.g., A7BS-206-PM, A7BS-207-PM-1, or A7BS-206-MP). There is no "-MP" type available, however, for A7BS-20@-S models.
*1. For models with PCB terminals, add "-P2" to the model number (e.g., A7BS-207-P2-1).
*2. Models with internal stoppers are also available. Add "-S@@" after the "206" or "207" in the model number and specify the display range in the
@@.
For example,
to specify the range 0 to 6, add "-S06" to the model number (e.g., A7BS-206-S06-1).
*3. Models with diodes are available. Add "-D" to the model number (e.g., A7BS-207-D or A7BS-207-D-1).
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
1
A7BS/A7BL
Accessories (Order Separately)
Use accessories, such as End Caps, Spacers, and Connectors with the Switch Units.
End Caps, Spare Units, and Connectors
Accessory
Color
End Caps (1 pair)
Spacer
Solder terminals
Connectors
PCB terminals
Light gray
Black
A7B-M *
A7B-M-1 *
A7B-P@ (See note.)
A7B-P@-1 (See note.)
A7B-C
A7B-CP
Note: The
@
in the Spacer model number stands for a letter in the range A to U. (Refer to the table in the following explanation about Spacers.)
* The minimum ordering unit is 10.
End Caps
End Caps are used on the Switch Units at each end and allow all the
Switch Units to be securely mounted to a panel. They come in pairs,
one for the left and one for the right.
Spacers
Spacers are used for creating extra space or gaps between the
Switch Units and have the same dimensions as the Switch Units
themselves.
There are also Spacers with engraved characters or symbols that
can be used for indicating units, such as time and length. (Refer to
the following table.) Consult your OMRON representative for
details.
Symbol
Stamp
Symbol
Stamp
A
No des-
ignation
H
cm
B
SEC
J
m
C
MIN
K
C
D
H
L
PCS
E
g
Q
x 10 SEC
F
kg
T
0
G
mm
U
•
Specifications
Switching capacity (resistive load)
Continuous carry current
Contact resistance
Between non-connected
terminals
Insulation
resistance Between terminal and
non-current carrying part
Between non-connected
terminals
Dielectric
strength
Between terminal and
non-current carrying part
Vibration resistance
Shock resistance
Mechanical
Durability
Electrical
Ambient temperature
Ambient humidity
Max. operating force
5 to 28 VDC or 50 VAC
1 mA to 0.1 A
1 A max.
300 m max.
10 M
min. (at 500 VDC)
min. (at 500 VDC)
1,000 M
600 VAC, 50/60 Hz for 1 min
1,000 VAC, 50/60 Hz for 1 min
10 to 55 Hz, 1.5-mm double amplitude
490 m/s
2
min.
100,000 operations min.
50,000 operations min.
Operating: -10 C to 65 C (with no icing)
Storage: -20 C to 80 C
Operating: 45% to 85%
5.39 N max.
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
2
A7BS/A7BL
Dimensions
Switches
A7BS-2@@(-1)
Solder Terminals
5.5
8
±
0.1
A
2.8
(Unit: mm)
*
24.5
(Unit: mm)
Number of
Switches
(n)
20.6 22
Size A
Size B
(n x 8 + 8) (n x 8 + 6)
16
24
32
40
48
56
64
72
80
88
14
22
30
38
46
54
62
70
78
86
Size C
14.4
22.4
30.4
38.4
46.8
54.8
62.8
70.8
78.8
86.8
24
16
2.6
Solder terminal
Panel thickness: 1 to 3
3.8
* If the output code is 06 or 54, the dimension is 32.5;
if the output code is 07 or 55, the dimension is 43.5.
1
2
3
4
5
6
7
8
9
10
Panel Cutout
0.4
22.4
+
0
3
6.9
0.8
B
P=8
±
0.2
C
+0.3
0
Note: 1. The dimensions above include both End
Caps, and will increase 8 mm for each
Spacer inserted.
2. Unless otherwise specified, a tolerance of
0.4 mm applies to all dimensions.
The tolerance for multiple connection is
(number of units x 0.4) mm.
Thumbwheel Switches with External Stoppers:
A7BS-20@-S(-1)
Use A7BS-S Stopper Pins to make dial display restrictions for these Switches.
Insert the Stopper Pins in the positions required to give the desired display range. For
example, for a display range of 0 to 5, insert a Stopper Pin at position 1 (see following
diagram) to stop the display from going above 5 when the (+) button is pressed, and insert
a Stopper Pin at position 2 to stop the display from going below 0 when the (-) button is
pressed.
Refer to page 7 for details.
Stopper Pins
2.4 dia.
0.4
2.7
1.2 dia.
Note: 1. Two pins constitute one set.
2. The first shipment is free and is attached
to the Switch.
Order the A7BS-S separately if it is
required for maintenance.
32.5
24.5
9
8
0
1
2
6
5
4
3
5.5
2.8
9
8
16
2.6
24
7
6
5
Pin insertion position (2)
0
1
2
3
4
22 20.6
7
Ten, 1.2 dia.
Pin insertion position (1)
A7BL-206(-1)
A7BL-207(-1)
Solder Terminals,
Locking Models
24
(Unit: mm)
6.1
8
±
0.1
A
2.8
*
24.5
Number of
Switches
(n)
Size A
Size B
(n x 8 + 8) (n x 8 + 6)
Size C
15.4
2
20.6 22
Solder terminal
When setting
Panel thickness: 1 to 3
3.6
* If the output code is 06, the dimension is 32.5;
if the output code is 07, the dimension is 43.5.
1
2
3
4
5
6
7
8
9
10
16
24
32
40
48
56
64
72
80
88
14
22
30
38
46
54
62
70
78
86
14.4
22.4
30.4
38.4
46.8
54.8
62.8
70.8
78.8
86.8
Panel Cutout
22.4
+0.4
0
3
6.9
0.8
B
P=8
±
0.2
0.3
C+
0
Note: 1. The dimensions above include both End
Caps, and will increase 8 mm for each
Spacer inserted.
2. Unless otherwise specified, a tolerance of
0.4 mm applies to all dimensions.
The tolerance for multiple connection is
(number of units x 0.4) mm.
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
3
A7BS/A7BL
Accessories (Order Separately)
End Caps for Push-operated Switches
A7B-M(-1) Snap-in Panel Mounting
Left Side
(30)
24
3.2
2.8
4
Right Side
4
2.8
(30)
24
3.2
24.5
24.5
2.4
22
(3.5)
3
3
(3.5)
3
22
Spacers for Push-operated Switches
A7B-P@(-1) Snap-in Panel Mounting
24
22
3
8
±0.1
2.8
24.5
The
@
in the Spacer model number stands for a letter in the range A to U. (Refer to the table under the explanation about Spacers on page 2.)
Note: Unless otherwise indicated, dimensional tolerances for dimensions in the models above are
±
0.4 mm.
Connectors
(These devices allow Switches to be quickly removed for maintenance and inspection of connectivity, and quickly re-installed.)
A7B-C
Solder Terminals
37
31
24
21
7.8
3.3 dia.
Inserting Connectors
9
20.5
13.5
Insert Connectors with the "UP" arrow
pointing up.
P=2.54
1
2
3
4
5
6
7
UP
3
22
A7B-CP
PCB Terminals
7.8
24
21
9
17.5
Connector
13.5
UP
7
6
0.6 x 0.6
P = 2.54
1
2
3
4
5
3
22
Note: Unless otherwise indicated, dimensional tolerances for dimensions in the models above are
±
0.4 mm.
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
4
A7BS/A7BL
Output Codes/Terminals
Switches with output codes 06 or 07 both use binary coded decimal
but Switches with output code 07 have a component-adding
provision. Similarly, Switches with output codes 54 or 55 both use
binary coded hexadecimal but Switches with output code 55 have
a component-adding provision.
How to Read Output Codes
For example, when the dial position is "3," the common terminal C
on the Switch is connected to terminals 1 and 2. When the Switch
is inserted into the Connector, the common terminal C becomes
connector terminal 2, and terminals 1 and 2 become connector
terminals 4 and 5 respectively.
Output codes
Output code
number
Terminals
Model
06
Fourteen,
1-dia. holes
06
07
Dial
07
Twenty-eight,
1-dia. holes
Switch Unit or Common ter-
Connector
minal number
Switch Unit
C
Connector
2
Connector
1
0
1
2
3
4
5
6
7
8
9
Terminals connected to
common
1
2
4
8
4
5
6
7
4
5
6
7
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Note: The solid dot
●
indicates that the internal switch is ON
(i.e., connected to the common terminal).
Component-adding provision
Dial
0
1
2
3
4
5
6
7
8
9
0
●
1
●
Terminal connected to common
2
3
4
5
6
7
8
9
1.3
9
8
6
7
5
3
1
8
6
4
2
0
●
●
●
●
●
●
●
●
19
P=3.6
4
2
20.6
Nineteen,
1-dia. holes
15
2.5
15
2.5
2.5
Note: The solid dot
●
indicates that the internal switch is ON
(i.e., connected to the common terminal).
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
[i=s]This post was last edited by qwqwqw2088 on 2020-11-10 08:49[/i]With the widespread use of Type-C, the previous USB charging solutions gradually need Type-C Power Delivery (PD) to achieve more eff...
Radar sensors using millimeter wave technology provide high accuracy and flexibility for many types of in-cabin monitoring applications, and due to their small size, they can be easily and concealedly...
The research on electrostatic discharge (ESD) theory is quite mature. In order to simulate and analyze electrostatic events, many electrostatic discharge models have been designed by predecessors. Com...
Let's verify the official examples below. Since the examples are simple in function, downloading programs, one by one verification, lighting, key functions, serial port sending and receiving are all i...
Medical imaging, especially ultrasound imaging technology, is undergoing a transformation. In the past, medical personnel used cart-mounted high-performance ultrasound systems to diagnose patients, bu...
[i=s]This post was last edited by MianQi on 2021-3-17 10:56[/i]This test: [RISC-V MCU Application Development]Chapter 80, CH32V103 Application Tutorial - DC Brushed Motor Key Control
Website: https://...