D2RV
Miniature Basic Switch
High Reliability for Micro Load
Applications, Even in Adverse
Atmospheres (Dust, High
Humidity, Silicon Gas, etc.)
●
The reed switch offers exceptional contact
reliability in micro load applications.
●
Same mounting pitch as for the V Miniature Basic
Switch.
●
High durability with a bounce time of 1 ms max.
RoHS Compliant
D
2
R
V
Model Number Legend
1 2
D2RV-
@ @
1. Actuator
None : Pin plunger model
L11 :
Short
hinge lever
L
L13
L22
L2
:
:
:
:
Hinge lever
Simulated
roller lever
Short
hinge roller lever
Hinge roller lever
Contact Form
●SPST-NO
Reed
switch
NO
COM
Ratings
Switching voltage
Switching current
Contact capacity
100 VDC (max.)
0.25 ADC (max.)
10 WDC (max.)
2. Maximum Operating Force (OF)
None : 0.49 N
{50
gf}
E : 0.25 N
{25
gf}
(for pin plungers only)
G : 0.98 N
{100
gf}
Note. These values are for the pin plunger models.
Note. The above rating values apply under the following test conditions.
(1) Ambient temperature: 20±2°C
(2) Ambient humidity: 65±5%
(3) Operating frequency: 30 operations/min
Characteristics
Permissible operating speed
Permissible
operating
frequency
Mechanical
Electrical
0.1mm to 1 m/s (for pin plunger models)
200 operations/min
200 operations/min
100 MΩ min. (at 500 VDC with insulation tester)
150 mΩ max.
200 VDC 1 min
List of Models
Actuator
Pin
plunger
Short hinge
lever
Hinge lever
Simulated
roller lever
Short hinge
roller lever
Hinge roller
lever
Maximum
Operating
Force (OF)
0.25 N {25 gf}
0.49 N {50 gf}
0.98 N {100 gf}
0.49 N {50 gf}
0.98 N {100 gf}
0.25 N {25 gf}
0.49 N {50 gf}
0.25 N {25 gf}
0.49 N {50 gf}
0.49 N {50 gf}
0.98 N {100 gf}
0.25 N {25 gf}
0.49 N {50 gf}
Model
D2RV-E
D2RV
D2RV-G
D2RV-L11
D2RV-L11G
D2RV-L
D2RV-LG
D2RV-L13
D2RV-L13G
D2RV-L22
D2RV-L22G
D2RV-L2
D2RV-L2G
Insulation resistance
Contact resistance (initial value)
Between terminals of
the same polarity
Dielectric
strength * 1
Between current-
carrying metal parts and 500 VAC 50/60 Hz for 1 min
ground
Between each terminal
and non-current-
carrying metal parts
500 VAC 50/60 Hz for 1 min
10 to 55 Hz, 1.5 mm double amplitude
500 m/s
2
{approx. 50G} max.
200 m/s
2
{approx. 20G} max.
10,000,000 operations min. (60 operations/min)
3,000,000 operations min. (30 operations/min)
IEC IP40
–10°C to
+60°C
(at ambient humidity of 60% max.)
(with no icing or condensation)
80% max. (for
+5°C
to
+35°C)
Approx. 7g (for pin plunger models)
Vibration
Malfunction
resistance * 2
Shock
resistance
Durability * 3
Destruction
Malfunction * 2
Mechanical
Electrical
Degree of protection
Ambient operating temperature
Ambient operating humidity
Weight
Note. The data given above are initial values.
*1. The values for dielectric strength shown are for models with a Separator
(refer to "Basic
Switch Common Accessories").
*2. For the pin plunger models, the above values apply for use at the free
position and total travel position. For the lever models, they apply at the
total travel position. Close or open circuit of the contact is 1ms max.
*3. For testing conditions, consult your OMRON sales representative.
Separator (Sold Separately), Actuator (Sold Separately), Terminal Connector (Sold Separately)
Refer to
"Basic Switch Common Accessories"
1
D2RV
Terminals/Appearances
6.3
3.2
t=0.5
2-Solder terminals
4.8
Miniature Basic Switch
(Unit:mm)
Mounting Holes
(Unit: mm)
2-3.1 dia. mounting holes
or M3
screw
holes
10.3
±0.1
2.4 dia. 1.3 dia.
22.2
±0.1
5.4 15.9
D
2
R
V
1
(10)
Dimensions
(Unit: mm)
/Operating Characteristics
●Pin
Plunger
D2RV-E
D2RV
D2RV-G
A
PT
2.8
20.2
±0.25
R1.5
5.15
3.1
+0.13
−0.03
dia. holes
4.3
Model
Operating
characteristics
Operating Force
OF Max.
D2RV-E
0.25 N
{25 gf}
D2RV
0.49 N
{50 gf}
1.6 mm
0.6 mm
0.8 mm
14.4±0.6 mm
D2RV-G
0.98 N
{100 gf}
OP
10.3
±0.1
5.4 15.9
2.8
3.1
+0.13
−0.03
3.4
±0.15
dia.
22.2
±0.1
2.8
27.8
10.3
1
(10)
Pretravel
PT Max.
Overtravel
OT Min.
Movement Differential MD Max.
Operating Position
OP
●Short
Hinge Lever
D2RV-L11
D2RV-L11G
22.1
PT
A
t=0.5
*
5.15
8.1
3.1
+0.13
−0.03
dia. holes
4.3
Model
Operating
characteristics
Operating Force
OF Max.
D2RV-L11
0.49 N
{50 gf}
D2RV-L11G
0.98 N
{100 gf}
1.8 mm
0.4 mm
1.0 mm
15.0±0.6 mm
OP
10.3
±0.1
5.4 15.9
2.8
3.1
+0.13
−0.03
3.4
±0.15
dia.
1
(10)
* Stainless-steel
lever
10.3
22.2
±0.1
2.8
27.8
Pretravel
PT Max.
Overtravel
OT Min.
Movement Differential MD Max.
Operating Position
OP
●Hinge
Lever Models
D2RV-L
D2RV-LG
PT
A
35.6
±0.8
t=0.5
*
5.15
8.1
3.1
+0.13
−0.03
dia. holes
4.3
Model
Operating
characteristics
Operating Force
OF Max.
D2RV-L
0.25 N
{25 gf}
4.0 mm
1.0 mm
1.6 mm
14.4±1.2 mm
D2RV-LG
0.49 N
{50 gf}
OP
10.3
±0.1
5.4 15.9
2.8
3.1
+0.13
−0.03
3.4
±0.15
dia.
1
(10)
* Stainless-steel
lever
10.3
22.2
±0.1
2.8
27.8
Pretravel
PT Max.
Overtravel
OT Min.
Movement Differential MD Max.
Operating Position
OP
●Simulated
Roller Lever Models
R3.5
D2RV-L13
PT
A
D2RV-L13G
t=0.5
*
32.6
±0.8
8.1
3.1
+0.13
−0.03
dia. holes
5.15
4.3
Model
Operating
characteristics
Operating Force
OF Max.
D2RV-L13
0.25 N
{25 gf}
4.0 mm
1.0 mm
1.6 mm
18.1±1.2 mm
D2RV-L13G
0.49 N
{50 gf}
OP
10.3
±0.1
2.8
3.1
+0.13
−0.03
3.4
±0.15
dia.
22.2
±0.1
2.8
27.8
10.3
1
(10)
* Stainless-steel
lever
5.4 15.9
Pretravel
PT Max.
Overtravel
OT Min.
Movement Differential MD Max.
Operating Position
OP
Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Note 2. The operating characteristics are for operation in the A direction ( ).
2
D2RV
●Short
Hinge Roller Lever Models
D2RV-L22
D2RV-L22G
PT
t=0.5
*1
A
20.1
8.1
3.1
+0.13
dia. holes
−0.03
4.8 dia.×4.8
*2
5.15
Miniature Basic Switch
Model
Operating
characteristics
Operating Force
OF Max.
D2RV-L22
0.49 N
{50 gf}
D2RV-L22G
0.98 N
{100 gf}
1.8 mm
0.4 mm
1.0 mm
20.4±0.6 mm
OP
10.3
±0.1
2.8
3.1
+0.13
−0.03
3.4
±0.15
dia.
22.2
±0.1
2.8
27.8
10.3
1
(10)
*1. Stainless-steel
lever
*2.
Polyacetal resin roller
5.4 15.9
Pretravel
PT Max.
Overtravel
OT Min.
Movement Differential MD Max.
Operating Position
OP
D
2
R
V
●Hinge
Roller Lever Models
D2RV-L2
PT
D2RV-L2G
t=0.5
*1
A
34
±0.8
8.1
3.1
+0.13
dia. holes
−0.03
4.8 dia.×4.8
*2
5.15
Model
Operating
characteristics
Operating Force
OF Max.
D2RV-L2
0.25 N
{25 gf}
4.0 mm
1.0 mm
1.6 mm
19.9±1.2 mm
D2RV-L2G
0.49 N
{50 gf}
OP
10.3
±0.1
2.8
3.1
+0.13
−0.03
3.4
±0.15
dia.
22.2
±0.1
2.8
27.8
10.3
1
(10)
*1. Stainless-steel
lever
*2.
Polyacetal resin roller
5.4 15.9
Pretravel
PT Max.
Overtravel
OT Min.
Movement Differential MD Max.
Operating Position
OP
Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Note 2. The operating characteristics are for operation in the A direction ( ).
Precautions
★Please
refer to "Basic Switches Common Precautions" for correct use.
Cautions
●Handling
Do not drop the Switch or apply strong shock. It may result in
internal mechanism damages and may deteriorate the
characteristics of the inner Reed Switch.
Correct Use
●Effect
of the External Magnetic Fields
• If two or more switch units are closely installed, mutual
interference due to the fringing field will occur, resulting in
malfunction. Be sure to keep the gap between the switch units
8 mm or more.
• If you install the switch unit on the iron plate, each operating
characteristic will change. Therefore, confirm that the interval
between the switch units should be 2 mm or more.
• Do not use the switch in some area where a strong external
magnetic field would be applied, otherwise malfunction will be
caused.
• Use nonmagnetic brass or stainless steel (SUS304 alloy)
screws for installation. Do not use any iron screw.
●Effect
of the External Vibration
When a vibration of 1 kHz or higher is applied, note that false
switching operations may occur due to resonant frequency, even
with a low acceleration.
●Soldering
• Terminal connections
Complete the soldering at the iron tip temperature between
250 to 350°C (60W) within 5 seconds, and do not apply any
external force for 1 minute after soldering.
Apply minimum amount of flux required. It may result in
contact failure once the flux penetrates into the internal part of
the Switch.
3
D2RV
Miniature Basic Switch
D
2
R
V
•
Application examples provided in this document
are
for reference only. In
actual applications,
confirm equipment functions
and safety before using
the product.
•
Consult your OMRON representative
before using
the product
under
conditions which
are
not described in the manual or
applying
the product to nuclear control
systems,
railroad
systems, aviation systems,
vehicles, combustion
systems,
medical equipment,
amusement
machines,
safety
equipment,
and
other
systems
or equipment that may have
a serious
influence on lives
and
property if
used
improperly. Make
sure
that the ratings
and
performance characteristics of the product provide
a
margin of
safety
for the
system
or
equipment,
and be sure
to provide the
system
or equipment with double
safety
mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. B056-E1-04
0812(0207)(O)
4