Note: The A3PJ is shown in the figure above as an example.
■
Specifications: Refer to page 15.
■
Panel cutout: Refer to page 21.
■
Dimensions: Refer to page 18.
■
Accessories, replacements, and tools: Refer to pages 13 to 15.
■
Precautions for correct use: Refer to page 24.
1
A3P
Model Number Structure
Model Number Legend
..... The model numbers used to order sets of Units are illustrated below. One set comprises the Pushbutton,
Lamp, and Switch.
For information on combinations, refer to
Ordering Information
on pages 3 to 7.
(5)
(1)
(2) (3) (4)
(6)
............... Single screen
24E R
A 3 P J - 90 B 1 1 -
24E RW
Upper Lower
................... Horizontal 2-split screen
R (Red)
Upper
W (White) Lower
(1) Shape of
Pushbutton
Symbol
J
Shape
Rectan-
gular
Square
Round
(2) Switch
Specifications
Standard Load
(3) Screen Pattern
Illumination-only models
Symbol
Screen pattern
1
Symbol
Operation
Momentary
A
SPDT
A
B
Alternate
T
Momentary
C
DPDT
Momentary opera-
D
Alternate
tion: Self-resetting
Alternate opera-
Microload
tion: Self-holding
Symbol
Operation
Momentary
E
SPDT
F
Alternate
G
Momentary
DPDT
H
Alternate
•
Standard Load
250 VAC, 3 A
30 VDC, 3 A
•
Microload
125 VAC, 0.1 A
30 VDC, 0.1 A
Minimum applicable load
5 VDC, 1 mA
•
3PDT models are also
available.
Select from among the
individual products shown on
page 12.
Single screen
(4) Case Color (5) Lighting
(6) Color of Pushbutton
Method
For LED
Sym-
Color
bol
LED-lighted Models
Symbol Color
1
Black
(A3PJ and A3PA
R
Red
Light
Models Only)
O
orange
2
gray
Note: A3PT
models are
available in
light gray
only.
Symbol
05E
12E
24E
2
2-split screen
Chameleon *1
Rated
voltage
5 VDC
12 VDC
24 VDC
G
W
K
green
white
Chameleon
G
Note: 1. The chameleon screen pattern
is not available with A3PT models.
2. The chameleon screen pattern
is only available with 12 or 24-VDC
models.
LED Lamp-
lighted Models
(A3PT Only)
Symbol
05C
12C
24C
Rated
voltage
5 VDC
12 VDC
24 VDC
•
The chameleon
screen pattern is not
available with A3PT
models.
•
The chameleon
screen pattern is only
available with 12 or
24-VDC models.
*1. With chameleon models, the whole
screen lights red, green, or orange.
When not lit, the display is white.
•
The available rectangular models are
shown below. Select from among the
individual products shown on page 10.
For Incandescent
Lamp
Symbol
No
symbol
Color
Red,
orange,
white,
blue,
green
Vertical 2-split
screen models
4-split screen
models
•
A3PJ and A3PA
can also be
ordered
separately. Refer
to page 10 for
details.
Horizontal 3-split Vertical 3-split
screen models screen models
Incandescent
Lamp-lighted
Models
Symbol
06
14
28
Rated
voltage
6 VAC/VDC
14 VAC/VDC
28 VAC/VDC
•
Includes colored
plate. Refer to page
11 for details.
The above diagrams show the Switches
with the "
" mark facing down.
Colored-illumination models up
to the 4-split screen models are
available as individual Units.
Refer to page 8.
“Colored-illumination” models
operate in the way shown below:
Unlit
White
Lit
Color
The built-in LED
is colored.
Number of LED Lamps
Screen pattern
Single screen
Horizontal 2-split screen
Vertical 2-split screen
Horizontal 3-split screen
Vertical 3-split screen
4-split screen
*2. These split screen models are available only as individual Units.
They cannot be ordered as sets.
4
*2
A3PJ
A3PA
A3PT
2
Number of Incandescent Lamps
Screen pattern
Single screen
Horizontal 2-split screen
Vertical 2-split screen
Horizontal 3-split screen
4-split screen
A3PJ
2
4(Low-pow-
er incan-
descent
lamp)
A3PA
1
2
A3PT
2
Models with built-in LED
---
---
---
---
---
---
---
---
---
---
Note: Lamp positions for single-screen A3PJ (rectangular model).
2
A3P
Ordering Information
Ordering as a Set
................................. The model numbers used to order sets of Units are given in the following tables. One set comprises
the Pushbutton, Lamp, and Switch.
(Not all combinations are possible. Ask your OMRON representative for details.)
Rectangular
Models
(Single Screen)
(Single Screen)
(1)
A3PJ
Standard Loads
Contact type
Operation
Output
Lighting
LED
Case color
5 VDC
12 VDC
24 VDC
SPDT Chameleon
12 VDC
24 VDC
Standard load (250 VAC, 3 A; 30 VDC, 4 A)
Momentary operation (Self-resetting)
Black
A3PJ-90A11-05E(1)
A3PJ-90A11-12E(1)
A3PJ-90A11-24E(1)
A3PJ-90AG1-12EK
A3PJ-90AG1-24EK
A3PJ-90A11-06
A3PJ-90A11-14
A3PJ-90A11-28
A3PJ-90C11-05E(1)
A3PJ-90C11-12E(1)
A3PJ-90C11-24E(1)
A3PJ-90CG1-12EK
A3PJ-90CG1-24EK
A3PJ-90C11-06
A3PJ-90C11-14
A3PJ-90C11-28
Light gray
A3PJ-90A12-05E(1)
A3PJ-90A12-12E(1)
A3PJ-90A12-24E(1)
---
A3PJ-90AG2-24EK
A3PJ-90A12-06
A3PJ-90A12-14
A3PJ-90A12-28
A3PJ-90C12-05E(1)
A3PJ-90C12-12E(1)
A3PJ-90C12-24E(1)
A3PJ-90CG2-12EK
A3PJ-90CG2-24EK
A3PJ-90C12-06
A3PJ-90C12-14
A3PJ-90C12-28
Alternate operation (Self-holding)
Black
A3PJ-90B11-05E(1)
A3PJ-90B11-12E(1)
A3PJ-90B11-24E(1)
A3PJ-90BG1-12EK
A3PJ-90BG1-24EK
A3PJ-90B11-06
A3PJ-90B11-14
A3PJ-90B11-28
A3PJ-90D11-05E(1)
A3PJ-90D11-12E(1)
A3PJ-90D11-24E(1)
A3PJ-90DG1-12EK
A3PJ-90DG1-24EK
A3PJ-90D11-06
A3PJ-90D11-14
A3PJ-90D11-28
Light gray
A3PJ-90B12-05E(1)
A3PJ-90B12-12E(1)
A3PJ-90B12-24E(1)
A3PJ-90BG2-12EK
A3PJ-90BG2-24EK
A3PJ-90B12-06
A3PJ-90B12-14
A3PJ-90B12-28
A3PJ-90D12-05E(1)
A3PJ-90D12-12E(1)
A3PJ-90D12-24E(1)
---
A3PJ-90DG2-24EK
A3PJ-90D12-06
A3PJ-90D12-14
A3PJ-90D12-28
*2
R
O
G
W
*1
*2
Pushbutton
color
symbol
R
O
G
W
*1
6 VDC/VAC
Incandescent
14 VDC/VAC
lamp
28 VDC/VAC
5 VDC
LED
12 VDC
24 VDC
DPDT Chameleon
12 VDC
24 VDC
6 VDC/VAC
Incandescent
14 VDC/VAC
lamp
28 VDC/VAC
Note: Enter the desired color symbol for the Pushbutton in (1). (R) = Red, (O) = Orange, (G) = Green, (W) = White.
Example: Red A3PJ-90A11-24E R
*1. You can change the screen colors of chameleon models between red, green, and orange, by changing the terminal wiring. Refer to page 20 for details.
*2. Incandescent lamps are supplied with colored plates (white, red, green, blue, and orange) and legend plates (milk-white and transparent). Use the appropriate combination.
Microloads
Contact type
Operation
Output
Lighting
LED
Case color
5 VDC
12 VDC
24 VDC
SPDT Chameleon
Incandescent
lamp
12 VDC
24 VDC
6 VDC/VAC
14 VDC/VAC
28 VDC/VAC
5 VDC
LED
12 VDC
24 VDC
DPDT Chameleon
Incandescent
lamp
12 VDC
24 VDC
6 VDC/VAC
14 VDC/VAC
28 VDC/VAC
Microload (125 VAC, 0.1 A; 30 VDC, 0.1 A)
Momentary operation (Self-resetting)
Black
A3PJ-90E11-05E(1)
A3PJ-90E11-12E(1)
A3PJ-90E11-24E(1)
A3PJ-90EG1-12EK
A3PJ-90EG1-24EK
A3PJ-90E11-06
A3PJ-90E11-14
A3PJ-90E11-28
A3PJ-90G11-05E(1)
A3PJ-90G11-12E(1)
A3PJ-90G11-24E(1)
A3PJ-90GG1-12EK
A3PJ-90GG1-24EK
A3PJ-90G11-06
A3PJ-90G11-14
A3PJ-90G11-28
Light gray
A3PJ-90E12-05E(1)
A3PJ-90E12-12E(1)
A3PJ-90E12-24E(1)
---
A3PJ-90EG2-24EK
A3PJ-90E12-06
---
A3PJ-90E12-28
---
A3PJ-90G12-12E(1)
A3PJ-90G12-24E(1)
---
A3PJ-90G12-06
A3PJ-90G12-14
A3PJ-90G12-28
*2
R
O
G
W
*1
*2
R
O
G
W
*1
Pushbutton
color symbol
Note: Enter the desired color symbol for the Pushbutton in (1). (R) = Red, (O) = Orange, (G) = Green, (W) = White.
Example: Red A3PJ-90E11-24E R
*1. You can change the screen colors of chameleon models between red, green, and orange, by changing the terminal wiring. Refer to page 20 for details.
*2. Incandescent lamps are supplied with colored plates (white, red, green, blue, and orange) and legend plates (milk-white and transparent). Use the appropriate combination.
Individual models: Refer to pages 9 to 12.
(The Pushbutton, Lamp, and Switch can be ordered separately.)
■
Specifications: Refer to page 15.
■
Dimensions: Refer to page 18.
■
Accessories: Refer to pages 13 to 15.
3
A3P
Ordering Information
Ordering as a Set
..................................The model numbers used to order sets of Units are given in the following tables. One set comprises
the Pushbutton, Lamp, and Switch.
(Not all combinations are possible. Ask your OMRON representative for details.)
(1)
(2)
Rectangular
(Horizontal 2-split Screen)
Models
Standard Loads
Contact type
Operation
Output
Lighting
LED
SPDT Incandescent
lamp
LED
DPDT Incandescent
lamp
Case color
5 VDC
6 VDC/VAC
14 VDC/VAC
28 VDC/VAC
24 VDC
6 VDC/VAC
14 VDC/VAC
28 VDC/VAC
(Horizontal 2-split Screen)
A3PJ
Standard load (250 VAC, 3 A; 30 VDC, 4 A)
Momentary operation (Self-resetting)
Black
A3PJ-90A21-24E(1)(2)
A3PJ-90A21-06
A3PJ-90A21-14
A3PJ-90A21-28
A3PJ-90C21-24E(1)(2)
A3PJ-90C21-06
A3PJ-90C21-14
A3PJ-90C21-28
Light gray
A3PJ-90A22-24E(1)(2)
A3PJ-90A22-06
A3PJ-90A22-14
A3PJ-90A22-28
A3PJ-90C22-24E(1)(2)
A3PJ-90C22-06
A3PJ-90C22-14
A3PJ-90C22-28
Alternate operation (Self-holding)
Black
A3PJ-90B21-24E(1)(2)
A3PJ-90B21-06
A3PJ-90B21-14
A3PJ-90B21-28
A3PJ-90D21-24E(1)(2)
A3PJ-90D21-06
A3PJ-90D21-14
A3PJ-90D21-28
Light gray
A3PJ-90B22-24E(1)(2)
A3PJ-90B22-06
A3PJ-90B22-14
A3PJ-90B22-28
A3PJ-90D22-24E(1)(2)
A3PJ-90D22-06
A3PJ-90D22-14
A3PJ-90D22-28
*
ROGW
*
ROGW
Pushbutton
color symbol
Note: Enter the desired color symbols for the Pushbutton in (1) and (2). (R) = Red, (O) = Orange, (G) = Green, (W) = White.
Example:
Red
White
Upper A3PJ-90D21-24E R W
Lower
Red White
* Incandescent lamps are supplied with colored plates (white, red, green, blue, and orange) and legend plates (milky white and transparent). Use the appropriate
combination.
Rectangular
(Horizontal 2-split Screen)
Models
Microloads
Contact type
Operation
Output
Lighting
LED
SPDT Incandescent
lamp
LED
DPDT Incandescent
lamp
Case color
5 VDC
6 VDC/VAC
14 VDC/VAC
28 VDC/VAC
5 VDC
6 VDC/VAC
14 VDC/VAC
28 VDC/VAC
(Horizontal 2-split Screen)
(1)
(2)
A3PJ
Microload (125 VAC, 0.1 A; 30 VDC, 0.1 A)
Momentary operation (Self-resetting)
Black
A3PJ-90E21-24E(1)(2)
A3PJ-90E21-06
A3PJ-90E21-14
A3PJ-90E21-28
A3PJ-90G21-24E(1)(2)
A3PJ-90G21-06
A3PJ-90G21-14
A3PJ-90G21-28
Light gray
A3PJ-90E22-24E(1)(2)
A3PJ-90E22-06
A3PJ-90E22-14
A3PJ-90E22-28
A3PJ-90G22-24E(1)(2)
A3PJ-90G22-06
A3PJ-90G22-14
A3PJ-90G22-28
*
ROGW
*
ROGW
Pushbutton
color symbol
Note: Enter the desired color symbols for the Pushbutton in (1) and (2). (R) = Red, (O) = Orange, (G) = Green, (W) = White.
Example:
Red
White
Upper A3PJ-90D21-24E R W
Lower
Red White
* Incandescent lamps are supplied with colored plates (white, red, green, blue, and orange) and legend plates (milky-white and transparent). Use the appropriate
combination.
Individual models: Refer to pages 9 to 12.
(The Pushbutton, Lamp, and Switch can be ordered separately.)
■
Specifications: Refer to page 15.
■
Dimensions: Refer to page 18.
■
Accessories: Refer to pages 13 to 15.
4
A3P
Ordering Information
Ordering as a Set
................................. The model numbers used to order sets of Units are given in the following tables. One set comprises
the Pushbutton, Lamp, and Switch.
(Not all combinations are possible. Ask your OMRON representative for details.)
Square
Models
(Single Screen)
(Single Screen)
(1)
A3PA
Contact type
Operation
Standard load (250 VAC, 3 A; 30 VDC, 4 A)
Momentary operation (Self-resetting)
Black
A3PA-90A11-05E(1)
A3PA-90A11-12E(1)
A3PA-90A11-24E(1)
A3PA-90AG1-12EK
A3PA-90AG1-24EK
A3PA-90A11-06
A3PA-90A11-14
A3PA-90A11-28
A3PA-90C11-05E(1)
A3PA-90C11-12E(1)
A3PA-90C11-24E(1)
A3PA-90CG1-12EK
A3PA-90CG1-24EK
A3PA-90C11-06
A3PA-90C11-14
A3PA-90C11-28
Light gray
A3PA-90A12-05E(1)
A3PA-90A12-12E(1)
A3PA-90A12-24E(1)
A3PA-90AG2-12EK
A3PA-90AG2-24EK
A3PA-90A12-06
A3PA-90A12-14
A3PA-90A12-28
A3PA-90C12-05E(1)
A3PA-90C12-12E(1)
A3PA-90C12-24E(1)
A3PA-90CG2-12EK
A3PA-90CG2-24EK
A3PA-90C12-06
A3PA-90C12-14
A3PA-90C12-28
Alternate operation (Self-holding)
Black
A3PA-90B11-05E(1)
A3PA-90B11-12E(1)
A3PA-90B11-24E(1)
A3PA-90BG1-12EK
A3PA-90BG1-24EK
A3PA-90B11-06
A3PA-90B11-14
A3PA-90B11-28
A3PA-90D11-05E(1)
A3PA-90D11-12E(1)
A3PA-90D11-24E(1)
A3PA-90DG1-12EK
A3PA-90DG1-24EK
A3PA-90D11-06
A3PA-90D11-14
A3PA-90D11-28
Light gray
A3PA-90B12-05E(1)
A3PA-90B12-12E(1)
A3PA-90B12-24E(1)
A3PA-90BG2-12EK
A3PA-90BG2-24EK
A3PA-90B12-06
A3PA-90B12-14
A3PA-90B12-28
A3PA-90D12-05E(1)
A3PA-90D12-12E(1)
A3PA-90D12-24E(1)
A3PA-90DG2-12EK
A3PA-90DG2-24EK
A3PA-90D12-06
A3PA-90D12-14
A3PA-90D12-28
*2
R
O
G
W
*1
*2
R
O
G
W
*1
Pushbutton
color symbol
Standard Loads
Output
Lighting
LED
Case color
5 VDC
12 VDC
24 VDC
SPDT Chameleon
Incandescent
lamp
12 VDC
24 VDC
6 VDC/VAC
14 VDC/VAC
28 VDC/VAC
5 VDC
LED
12 VDC
24 VDC
DPDT Chameleon
Incandescent
lamp
12 VDC
24 VDC
6 VDC/VAC
14 VDC/VAC
28 VDC/VAC
Note: Enter the desired color symbol for the Pushbutton in (1). (R) = Red, (O) = Orange, (G) = Green, (W) = White.
Example: Red A3PA-90A11-24E R
*1. You can change the screen colors of chameleon models between red, green, and orange, by changing the terminal wiring. Refer to page 20 for details.
*2. Incandescent lamps are supplied with colored plates (white, red, green, blue, and orange) and legend plates (milk-white and transparent). Use the appropriate combination.
Microloads
Contact type Microload (125 VAC, 0.1 A; 30 VDC, 0.1 A)
Operation
Output
Lighting
LED
Case color
5 VDC
12 VDC
24 VDC
SPDT Chameleon
Incandescent
lamp
12 VDC
24 VDC
6 VDC/VAC
14 VDC/VAC
28 VDC/VAC
5 VDC
LED
12 VDC
24 VDC
DPDT Chameleon
Incandescent
lamp
12 VDC
24 VDC
6 VDC/VAC
14 VDC/VAC
28 VDC/VAC
Momentary operation (Self-resetting)
Black
A3PA-90E11-05E(1)
A3PA-90E11-12E(1)
A3PA-90E11-24E(1)
A3PA-90EG1-12EK
A3PA-90EG1-24EK
A3PA-90E11-06
---
A3PA-90E11-28
---
A3PA-90G11-12E(1)
A3PA-90G11-24E(1)
A3PA-90GG1-12EK
A3PA-90GG1-24EK
A3PA-90G11-06
---
A3PA-90G11-28
Light gray
A3PA-90E12-05E(1)
A3PA-90E12-12E(1)
A3PA-90E12-24E(1)
---
A3PA-90EG2-24EK
A3PA-90E12-06
A3PA-90E12-14
A3PA-90E12-28
---
A3PA-90G12-12E(1)
A3PA-90G12-24E(1)
---
A3PA-90G12-06
---
A3PA-90G12-28
*2
R
O
G
W
*1
*2
R
O
G
W
*1
Pushbutton
color symbol
Note: Enter the desired color symbol for the Pushbutton in (1). (R) = Red, (O) = Orange, (G) = Green, (W) = White.
Example: Red A3PA-90E11-24E R
*1. You can change the screen colors of chameleon models between red, green, and orange, by changing the terminal wiring. Refer to page 20 for details.
*2. Incandescent lamps are supplied with colored plates (white, red, green, blue, and orange) and legend plates (milk-white and transparent). Use the appropriate combination.
Individual models: Refer to pages 9 to 12.
(The Pushbutton, Lamp, and Switch can be ordered separately.)
[align=center][/align] [align=left][font=宋体]The book "Basics of Power Supply Design" is the result of the technical compilation of the Unitrode/Texas Instruments Technical Seminar Project in the past ...
Currently, there is a biological electrode for measuring toxicity, and the electrode measurement characteristics are correlated with voltage. The electrode output fluctuates in the range of about 300m...
1. From November 2018 to March 2019, I opened Tencent News every day and saw layoffs everywhere, especially in the Internet and real estate industries. Does this environment have any impact on those w...
A: Please advise which pins should be connected when adding the Bluetooth module to IMX6B:
The core board and WIFI+Bluetooth module communicate via USB, just use HOST...
[size=4]【Question Requirements】[/size] [size=4] The difficulty of developing the perception layer in the 2018 National Vocational College Skills Competition "Internet of Things Technology Application"...
The brightness of the LED is adjusted by PWM and controlled by touch buttons.
When the button is touched, the duty cycle gradually increases and remains constant when it is released. Touch buttons k1 ...
Intel® Xeon® Scalable processors are the benchmark processors for cloud gaming, multimedia processing and transmission, virtual desktop infrastructure, and reasoning operations
, and are comm...[Details]
Nidec Corporation
's group company Nidec
Transmission Technology Co., Ltd. (
formerly Nidec Shinpo
) has developed
a new
precision speed reducer "
KINE...[Details]
It is undeniable that network technology has developed very rapidly and has become an indispensable part of our lives. But at the same time, it has also provided many criminals with opportuniti...[Details]
Recently, Zhuanxin Semiconductor (Nanjing) Co., Ltd. (hereinafter referred to as "Zhuanxin Semiconductor") announced the completion of nearly 100 million yuan in angel round financing, with investors...[Details]
When people buy electromagnetic flowmeters , it is almost impossible to dismantle and transport them to the National Metrology and Testing Center for calibration because the electromagnetic flowmeter...[Details]
The MCU and TLC2543 interface realizes AD conversion and uses digital tube display for simulation schematic diagram as follows (Proteus simulation project file can be downloaded from the attachment o...[Details]
The awareness and demand of various enterprises and organizations to protect personal safety and private and public property are increasing. With the development of video surveillance technology,...[Details]
0 Introduction In recent years, with the development of power line carrier communication (PLC) technology, power line carrier communication has been widely used in daily life and industrial produ...[Details]
2. Working method Mode 0: Extended shift register mode, shift rate fosc/12 ① When working in mode 0, data is input/output serially by RXD, and TXD outputs shift pulses to shift the external shift...[Details]
summary
This article details a method to create dual output voltage rails that can provide positive and negative voltage rails for device power supply (DPS) and requires only one b...[Details]
CRC decoding and error correction
The received cyclic check code is divided by the agreed generating polynomial G(x). If the codeword is correct, the remainder should be 0. If a certain bit i...[Details]
In the past two years, Huawei has established a firm foothold in the high-end mobile phone market with its P series and Mate series flagship phones. In the past, Huawei would release the P series fla...[Details]
1. Overview
LM2917 is a monolithic integrated frequency-voltage converter. The chip contains a high-gain operational amplifier/comparator. When the input frequency reaches or exceeds a given ...[Details]
In the design of electronic systems, in order to avoid detours and save time, the requirements for anti-interference should be fully considered and met, and anti-interference remedial measures should...[Details]