IC Sensors
MODEL 154N
316 SS Pressure Sensor
0-100 mV Output
Gage, Sealed Gage and Absolute
Temperature Compensated
Ultrastable
temperature
compensation
and offset
correction. An
additional
laser-trimmed
resistor is
included which
can be used to
adjust sensitivity
variations by
setting the gain of
an external
differential amplifier to
within ±1% interchangeability.
Alternatives include cap-ring Models 84 or 86,
1/4 NPT Model 96, and Model 85. High pressure
sensors are also available.
DESCRIPTION
The Model 154N
The Model 154N is a media
compatible, compensated, piezoresistive silicon
pressure sensor packaged in a 316 stainless steel
housing. The sensing package utilizes silicon oil to
transfer pressure from the 316 stainless steel
diaphragm to the sensing element.
The Model 154N is designed for low pressure
applications. A ceramic substrate is attached to the
package that contains laser-trimmed resistors for
FEATURES
O-ring Mount
±0.1% Pressure Non-linearity
-20ºC To +85ºC Compensated
Temperature Range
1.0% Interchangeable Span (provided
by gain set resistor)
Solid State Reliability
Low Power
6.00±.25
[152.4±6.4]
Dimensions
w/BACK END OPTIONS
BASIC SENSING ELEMENT
Ø.7413/.7427
[18.829/18.864]
DIAPHRAGM,
.001 [0.03] THICK
WELD RING
O-RING, BUNA-N,
Ø.070 [1.78]
.54
.24 [6.0]
EPOXY STRAIN RELIEF
RIBBON CABLE, 26 AWG
4X Ø.018 [0.46]
-O
-E
BALL SEAL
CONNECTOR, FEMALE,
MOLEX P/N 14-56-2066
(.100 [2.54] CENTERS)
APPLICATIONS
Medical Instruments
Process Control
Waste Water Management
Refrigeration/Compressors
Pressure Transmitters
Level Systems
VIEW SHOWN w/o CABLE
AND CONNECTOR FOR CLARITY
2X .18 [4.6]
PAD #1
+E
2X .09 [2.3]
3X .05 [1.3]
+O
Ø.745/.747
[18.92/18.97]
internet:www.msisensors.com
Tel: 1-757-766-1500
North America Toll Free: 1-800-745-8008
Fax: 1-757-766-4297
7/16/04
innovation performance reliability
Schaevitz
ICSensors
Microfused
Piezo Film
316 SS Pressure Sensor
IC Sensors
Ultrastable
MODEL 154N
PARAMETERS
Full Scale Output Span
Zero Offset
Pressure Non-linearity
Pressure Hysteresis
Input Resistance
Output Resistance
Temperature Error - Span
Temperature Error - Zero
Thermal Hysteresis - Span
Thermal Hysteresis - Zero
Long Term Stability of Offset
Long Term Stability of Span
Supply Current
Output Load Resistance
Insulation Resistance (50 VDC)
Pressure Overload
Compensated Operating Temperature
Operating Temperature Range
Storage Temperature Range
Media - Pressure Port
Media - Reference Port
Weight
Notes
MIN
75
-1
-0.10
-0.05
2000
4000
-0.75
-0.5
Performance Specifications
All parameters measured at 1.5mA drive and at 25°C after 10 second warm up, unless otherwise specified. Unless specifically indicated, only those
parameters indicated as tested are verified on each part. Parameters are specified for the compensated version only.
TYP
100
0
0.02
3500
MAX
150
1
0.10
0.05
4500
25000
0.75
0.5
UNITS
mV
mV
% Span
% Span
Ω
Ω
% Span
% Span
% Span
% Span
±% Span/yr.
±% Span/yr.
mA
MΩ
MΩ
Rated
NOTES
1.2
2
3
0.5
5
50
–20°C to +85°C
–40°C to +125°C
–50°C to +125°C
0.05
0.05
0.1
0.1
1.5
4
4, 5
4
4
2.0
6
7
8
9
9
9
3X
Liquids and Gases compatible with 316L Stainless Steel
Compatible with Silicon, Pyrex, Gold, Fluorosilicon Rubber and 316L Stainless Steel
24 grams
10
1. For amplified output circuits, 3.012V ± 1% interchangeability with
gainset resistor. See Application Note TN-003.
2. Measured at vacuum for absolute (A), ambient for gage (G).
3. Best fit straight line.
4. Over Temperature range: -20°C to +85°C Span with respect to +25°C.
5. 15 psi range sensors have a temperature error of ±0.75% (Max) of Zero
from -20°C to 85°C.
6. Guarantees output/input ratiometricity.
7. Load resistance to reduce measurement errors due to output loading.
8. Between case and sensing element.
9. Maximum temperature range for product with standard cable and
connector is –20°C to +105°C.
10. Weight depends upon configuration (cable, connector).
11. Standard gauge units are not recommended for vacuum applications.
For vacuum applications below 1/2 atmosphere, contact factory.
12. For pressure ranges < 15 psi, consult factory on performance
specifications.
S t a n d a rd R a n g e s
Range
psig
psia
Connections
Pad. No./Cable
Function
0
0
0
0
0
0
0
to
to
to
to
to
to
to
5
15
30
50
100
300
500
see low pressure version
•
•
•
•
•
•
•
•
•
•
•
•
1
2
3
4
5
6
+OUT
-EX
+EX
-OUT
GAIN
GAIN
Application Schematic
O rd e r i n g I n f o r m a t i o n
(Note 11)
(Note