Fully compatible with industry standard 10KH, 100K
I/O levels
s
Internal 75K
Ω
input pulldown resistors
s
Fully compatible with Motorola MC10E/100E112
s
Available in 28-pin PLCC package
DESCRIPTION
The SY10/100E112 are quad drivers designed for use
in new, high-performance ECL systems. The E112 has two
pairs of OR/NOR outputs from each gate and a common,
buffered enable input. The data input can also be used as
an ECL memory address fan-out driver, although the E111
is designed specifically for this purpose, and offers lower
skew than the E112. For memory address driver applications
where scan capabilities are required, please refer to the
SY10/100E212 device.
BLOCK DIAGRAM
Q
0a
Q
0b
Q
0a
Q
0b
Q
1a
D
1
Q
1b
Q
1a
Q
1b
Q
2a
Q
2b
Q
2a
Q
2b
Q
3a
Q
3b
Q
3a
Q
3b
PIN NAMES
Pin
D
0
-D
3
EN
Q
na
, Q
nb
Q
na
, Q
nb
V
CCO
Function
Data Inputs
Enable Input
True Outputs
Inverting Outputs
V
CC
to Output
D
0
D
2
D
3
EN
M9999-032006
hbwhelp@micrel.com or (408) 955-1690
Rev.: G
Amendment: /0
1
Issue Date: March 2006
Micrel, Inc.
SY10E112
SY100E112
PACKAGE/ORDERING INFORMATION
Ordering Information
(1)
V
CCO
Q
2b
Q
2a
Part Number
SY10E112JI
18
17
Package
Type
J28-1
J28-1
J28-1
J28-1
J28-1
J28-1
J28-1
J28-1
J28-1
J28-1
J28-1
J28-1
Operating
Range
Industrial
Industrial
Industrial
Industrial
Commercial
Commercial
Commercial
Commercial
Industrial
Industrial
Industrial
Industrial
Package
Marking
SY10E112JI
SY10E112JI
SY100E112JI
SY100E112JI
SY10E112JC
SY10E112JC
SY100E112JC
SY100E112JC
Lead
Finish
Sn-Pb
Sn-Pb
Sn-Pb
Sn-Pb
Sn-Pb
Sn-Pb
Sn-Pb
Sn-Pb
Q
3b
25 24 23 22 21 20 19
Q
3a
Q
3b
Q
3a
V
CCO
D
3
D
2
V
EE
D
1
D
0
EN
26
27
28
1
2
3
4
5
6
7
8
9
10 11
Q
2b
Q
2a
V
CC
Q
1b
Q
1a
Q
1b
Q
1a
SY10E112JITR
(2)
SY100E112JI
SY100E112JITR
(2)
SY10E112JC
SY10E112JCTR
(2)
SY100E112JC
SY100E112JCTR
(2)
SY10E112JY
(3)
SY10E112JYTR
(2, 3)
SY100E112JY
(3)
SY100E112JYTR
(2, 3)
Notes:
PLCC
TOP VIEW
J28-1
16
15
14
13
12
V
CCO
Q
0a
Q
0b
V
CCO
NC
Q
0a
Q
0b
28-Pin PLCC (J28-1)
SY10E112JY with
Matte-Sn
Pb-Free bar-line indicator
SY10E112JY with
Matte-Sn
Pb-Free bar-line indicator
SY100E112JY with
Matte-Sn
Pb-Free bar-line indicator
SY100E112JY with
Matte-Sn
Pb-Free bar-line indic ator
1. Contact factory for die availability. Dice are guaranteed at T
A
= 25°C, DC Electricals only.
2. Tape and Reel.
3. Pb-Free package is recommended for new designs.
M9999-032006
hbwhelp@micrel.com or (408) 955-1690
2
Micrel, Inc.
SY10E112
SY100E112
TRUTH TABLE
EN
L
H
Q
n
D
n
H
Q
n
D
n
L
DC ELECTRICAL CHARACTERISTICS
V
EE
= V
EE
(Min.) to V
EE
(Max.); V
CC
= V
CCO
= GND
T
A
=
–40
°
C
Symbol
I
IH
Parameter
Input HIGH Current
EN
D
Power Supply Current
10E
100E
—
—
47
47
56
56
—
—
47
47
56
56
—
—
47
47
56
56
—
—
47
54
56
65
T
A
= 0
°
C
T
A
= +25
°
C
Max. Min. Typ.
150
200
—
—
—
—
T
A
= +85
°
C
Max.
150
200
mA
Unit
µA
—
—
—
—
150
200
—
—
—
—
150
200
—
—
—
—
Min. Typ. Max. Min. Typ.
Max. Min. Typ.
I
EE
AC ELECTRICAL CHARACTERISTICS
V
EE
= V
EE
(Min.) to V
EE
(Max.); V
CC
= V
CCO
= GND
T
A
= –40
°
C
Symbol
t
PD
Parameter
Min.
Propagation Delay to Output
D
200
EN
275
Within-Device Skew
D
n
to Q
n
, Q
n
(1)
Q
na
to Q
nb
(2)
Rise/Fall Time
20% to 80%
—
—
275
T
A
= 0
°
C
T
A
= +25
°
C
Max. Min. Typ.
600
675
—
—
700
200
275
—
—
275
400
450
80
40
425
T
A
= +85
°
C
Typ. Max.
400
450
80
40
425
600
675
ps
80
40
425
—
—
700
—
—
275
80
40
425
—
—
700
—
—
275
—
—
700
ps
Unit
ps
400
450
600
675
200
275
400
450
600
675
200
275
Typ. Max. Min. Typ.
Max. Min.
t
skew
t
r
t
f
Notes:
1. Within-device skew is defined as identical transitions on similar paths through a device.
2. Skew defined between common OR or common NOR outputs of a single gate.
M9999-032006
hbwhelp@micrel.com or (408) 955-1690
3
Micrel, Inc.
SY10E112
SY100E112
28-PIN PLCC (J28-1)
Rev. 03
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131
TEL
USA
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
http://www.micrel.com
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.