TA35-C343HJ25-CZM23

Description
Thermal Circuit Breaker, 2 Pole(s), 2.5A, 240VAC, 60VDC, Panel Mount,
CategoryCircuit protection    Circuit protection   
File Size1001KB,6 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance
Download Datasheet Parametric View All

TA35-C343HJ25-CZM23 Overview

Thermal Circuit Breaker, 2 Pole(s), 2.5A, 240VAC, 60VDC, Panel Mount,

TA35-C343HJ25-CZM23 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid1978205133
Reach Compliance Codenot_compliant
Actuator typeROCKER
body width26 mm
body height43.9 mm
Body length or diameter39 mm
circuit functionTRIP FREE
Circuit protection typeTHERMAL CIRCUIT BREAKER
Environmental characteristicsIP40
Installation featuresPANEL MOUNT
Number of poles2
Maximum operating temperature60 °C
Minimum operating temperature-30 °C
physical size39mm x 26mm x 43.9mm
Rated breaking capacity2000 A
Rated current2.5 A
Rated voltage (AC)240 V
Rated voltage (DC)60 V
GuidelineCCC; CSA; CUL; GB; IEC; UL; VDE
surface mountNO
Terminal shapeQUICK CONNECT
Thermal (T- and TA-Line)
www.schurter.com/PG17_18_19
Circuit Breaker for Equipment thermal, Rocker actuation, 2 pole
TA35 Rocker 2Pole
Description
-
-
-
-
-
-
-
-
-
-
-
Thermal circuit breaker
2-pole
Snap-in version
Positively trip-free release
Different rocker colours
High configurability
Wide current range
IEC 60934
UL 1077
CSA C22.2 235
GB 17701
Characteristics
-
-
-
-
-
Power tools
Industrial appliances
Equipment for construction
Cleaning equipment
Commercial and household kitchen appliances
Weblinks
Standards
pdf-datasheet, html-datasheet, General Product Information,
Approvals, CE declaration of conformity, RoHS, CHINA-RoHS, e-Shop,
SCHURTER-Stock-Check, Distributor-Stock-Check, Detailed request for
product
Technical Data
Rated Voltage AC
Rated Voltage DC
Rated current range AC
Conditional short circuit ca-
pacity
Degree of Protection
Dielectric Strength
Insulation resistance
Endurance typical
240 V; 50/60 Hz
60 V
0.05 - 20 A
0.05...20 A: 2 kA, SC (C1) @ 240 VAC
from front side IP 40 acc. to IEC 60529
50 Hz: > 2.5 kV
Impulse 1.2/50
μs:
> 4 kV
500 VDC > 100 MΩ
mechanical: 50'000 switching cycles
AC: 1 x Ir, cos
φ
0.6:
50'000 switching cycles
DC: 1 x Ir, L/R = 2 - 3 ms:
50'000 switching cycles
Overload
Ambient temperature
Vibration Resistance
IEC: min. 40 trips
@ 6 x Ir, cos
φ
0.6
UL / CSA: min. 50 trips
@ 1.5 x Ir, cos
φ
0.75
-30 °C to 60 °C
± 0.75 mm @ 10 - 60 Hz
acc. to IEC 60068-2-6, test Tc
10 G @ 60 - 500 Hz
acc. to IEC 60068-2-6, test Tc
30 G / 18 ms
acc. to IEC 60068-2-27, test Ea
Thermal
29.0 - 31.5 g
Shock Resistance
Tripping Type
Weight
Dimension
36
34
7.2
1.7
29
20.9
26
+0.2
0
+0.3
44.1
10.5
LINE
10.6
34
Panel 1.0 − 4.0 mm
L
21.3
33.8
2.3
11 6.1
23.5
26
6.3 x 0.8 mm
33.5
Circuit Breakers
+0.2
0
1
[NXP Rapid IoT Review] +IOT First Experience and Web IDE Usage Process
[i=s] This post was last reviewed by flyword on 2018-12-27 16:29 Edit [/i] [align=left][b]1. Unboxing and initial experience. [/b][/align][align=left]I got the NXP Fast IOT Kit on the evening of Decem...
flyword RF/Wirelessly
GD32L233C-START Development Board Evaluation 3: GD32L233C Chip Low Power Performance Test (Continued)
GD32L233C-START Development Board Evaluation 3 : GD32L233C chip low power performance test (continued) Based on the test results of "Low Power Test 1", in order to confirm the chip current, it was dec...
hjl2832 GD32 MCU
【AT32F421 Review】+ COMP Comparator Usage
[i=s]This post was last edited by dmzdmz666666 on 2021-4-30 23:33[/i]In this chapter, I will test the internal comparator of AT32F421. AT32F421 has a low-power comparator inside, which can be used as ...
dmzdmz666666 Domestic Chip Exchange
Communication protocol conversion
I want to use a microcontroller to make a protocol converter, because the BMW host computer can only use kma200d protocol, but now there is only kma215 chip, so I need to convert 215 to 200 protocol t...
tl520 Sensor
New live broadcast calendar
Today I accidentally saw the newly added live broadcast calendar function, which I think is quite eye-catching. I can see the live broadcast activities of the month at a glance, which is good....
yanbao Talking
LOTO Practice [Dry Goods] 2- Quick Application of Voltage Comparator
Without further ado, here are the pictures:I recently went on a business trip to a customer's site to debug equipment. The scene is shown above. The technical part I was responsible for included a fun...
LOTO2018 Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号