The MINMAX AQF-30 series is a new range of fully encapsulated AC/DC power supply modules. The product features EMI-filter to EN55022, class B and
EMS compliance to EN 61000-4 standard. Universal input voltage 85-264VAC and International safety approvals qualifies these power modules for
applications in products with worldwide markets. For industrial applications, the models for chassis mounting can also be supplied as option with UL508
approval.The AQF-30 series provide a cost effective solution for many space critical applications in commercial and industrial electronic equipment.
Model Selection Guide
Model Number PCB Mounting
(For model with Chassis
Mounting, add suffix C)
VDC
AQF-30S05
AQF-30S12
AQF-30S15
AQF-30S24
AQF-30S48
AQF-30D12
AQF-30D15
AQF-30D512
AQF-30T512
5
12
15
24
48
±12
±15
Output
Voltage
Max.
mA
6000
2500
2000
1250
625
±1300
±1000
Peak
mA
---
---
---
---
---
---
---
4500
1800
4500
900
900
4500
1500
500
4500
750
750
6000
1500
500
5300
2000
500
Output Current
Input Current
115VAC, 60Hz
@Max. Load
@No Load
mA(typ.)
mA(typ.)
557
543
543
543
543
565
543
572
572
60
60
60
60
60
60
60
60
60
Max. capacitive
Load
μF
8000
3900
3900
1500
1000
#1500
#1500
3900
1500
2200
1500
1500
2200
1500
1500
2200
1500
1500
2200
2200
1500
2200
2200
1500
# For each output
Efficiency
(typ.)
@Max. Load
%
78
80
80
80
80
80
80
76
76
AQF-30T512A
AQF-30T515
AQF-30T5312P
AQF-30T3512P
*5
3000
*12
1250
*5
3000
12
600
-12
-600
*5
3000
12
1000
-12
-250
*5
3000
15
500
-15
-500
*5
4500
+3.3
1000
+12
250
*3.3
4000
+5
1500
+12
250
* Output floating (note 6)
Tel:886-6-2923150
572
60
76
572
60
76
588
60
71
483
60
71
E-mail:sales@minmax.com.tw
2012/11/14 REV:19
Page 1 of 5
AQF-30 SERIES
AC/DC POWER MODULE 30W
Input Specifications
Parameter
Input Voltage Range
Input Frequency Range
Input Voltage Range
Inrush Current (Cold Start at 25℃)
Model
All Models
115VAC
230VAC
Min.
85
47
120
---
---
Typ.
---
---
---
---
---
Max.
264
440
370
20
40
Unit
VAC
Hz
VDC
A
A
Output Specifications
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Vo1
Vo2
Vo3
Iout=Min. to Max.
Conditions
Single / Dual Output
Dual Positive / Triple Output
Vo1
Vo2&Vo3
Min.
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
Typ.
±1.0
±1.0
±3.0
±0.2
±0.5
±2.5
±2.5
±4.0
±2.0
±5.0
±5.0
1.5
1.0
10
20
120
±0.02
---
---
Max.
±2.0
±2.0
---
±1.0
±1.0
±5.0
±5.0
---
---
---
---
1.8
1.3
---
---
---
---
5
---
Unit
%
%
%
%
%
%
%
%
%
%
%
%V
PP
of Vo
%V
PP
of Vo
%Inom.
%Inom.
% of Vo
%/℃
% Vout
% Inom.
Vin=Min. to Max.
Single Output Models
Dual Output Models
Vo1
Triple Output Models
Vo2&Vo3
Cross Regulation-
Dual / Triple Output Models
Ripple & Noise (20MHz)
Minimum Load
Over Voltage Protection
Temperature Coefficient
Overshoot
Current Limitation
Short Circuit Protection
Measured output Io = 20% to 100% of rated load
Other output(s) set at 50% of rated load
3.3V & 5VDC Output Models
Other Output Models
Single-,Dual-Output Models and Main Output Triple Output Models
Auxiliary Outputs of Triple Output Models
Zener diode clamp
Foldback, auto-recovery
105
(long term overload condition may cause damage)
Hiccup mode, indefinite (automatic recovery)
General Specifications
Parameter
I/O Isolation Voltage
I/O Isolation Resistance
Switching Frequency
Hold-up Time
MTBF (calculated)
EMC Emission
Conditions
Input to Output, 60 Seconds
500 VDC
Min.
Typ.
Max.
Unit
3000
---
---
VACrms
100
---
---
MΩ
---
100
---
KHz
---
20
---
ms
200,000
---
---
Hours
EN 55011 class B, EN 55022 class B, FCC part 15 class B