BCM N
i
MH
W I D E R A N G E B AT T E RY C H A R G E R S
BCM NiMH WIDE RANGE
B AT T E RY C H A R G E R S
•
•
•
•
•
•
•
•
•
•
•
BCM NiMH
Ault Part No.
Number
of Cells
Volts
DC
Fast Charge
Current Amps
100-250 VAC
In Case IEC 320 with Ground
LED Indicators
Charges Nickel Metal Hydride Batteries
Optimizes Battery Life
Meets Safety Agency Requirements
Complies with EMI-RFI Regulations
Impact Resistant Polycarbonate Enclosure
Private Label Marking Available
3 Year Warranty
Modified and Custom Designs Also Available
BCM-*-306-150-00-21X
BCM-*-306-120-00-21X
BCM-*-306-100-00-21X
BCM-*-306-080-00-21X
BCM-*-306-060-00-21X
BCM-*-510-120-00-21X
BCM-*-510-100-00-21X
BCM-*-510-080-00-21X
BCM-*-510-060-00-21X
BCM-*-812-100-00-21X
BCM-*-812-080-00-21X
BCM-*-812-060-00-21X
Ault Part No. Key
Ault Part No. Key
3 – 06
3 – 06
3 – 06
3 – 06
5 – 10
5 – 10
5 – 10
5 – 10
5 – 10
8 – 12
8 – 12
8 – 12
3–9
3–9
3–9
3–9
3–9
5 – 15
5 – 15
5 – 15
5 – 15
8 – 18
8 – 18
8 – 18
1.5
1.2
1.0
0.8
0.6
1.2
1.0
0.8
0.6
1.0
0.8
0.6
BCM
Product
Family
Name
*
Denotes
Safety Timer
(see pg. 2)
306
Number
of Cells
150
Fast Charge
Current/Amps
00
21
X
Manufacturing
Location
Denotes standard Connector
or custom
requirements
A U LT I N C O R P O R AT E D
7105 Northland Terrace
|
Minneapolis, Minnesota 55428
|
USATEL (1) 763-592-1900
FAX (1) 763-592-1911
|
E-MAIL info@aultinc.com
|
WEB www.aultinc.com
© Copyright 2002 Ault Inc.
BCM N
i
MH
W I D E R A N G E B AT T E RY C H A R G E R S
Input
Voltage
Line Frequency
Current
Protection
100 - 250 VAC -10%, +6%
47 - 63 Hz
0.5 max at 120 VAC input
Internal primary current fuse
Inrush limiting
Short Circuit Protection
Environmental
Operating Temperature
Storage Temperature
Relative Humidity
Altitude
Cooling
Electrical
Mechanical
Topology
Dielectric Withstand
EMI
CE
MTBF
Protection
Switching - DC battery charger
Case and Dimensions
3000 VAC, 4242 VDC primary - secondary
Complies with EMC Directives
CE Compliant
100,000 calculated hours
Output current limiting,
Short circuit protection
Weight
Cords and Connectors
Case Material
4.22L x 2.60W x 1.51H (in)
107.2L x 66.04W x 38.35H (mm)
94V0 polycarbonate; black is standard
color; other colors available - extra
charges may apply
8 ounces, 210 grams (excluding cord)
6 ft., 3 conductor, 18 AWG, Ault #21
connector (thermistor is in pack). Other
connectors are also available.
0º – 50º C with no derating
-30º to +85º C
5% to 95% non-condensing
0-10,000 feet
0-10,000 feet
Convectional - non vented case
Safety Approvals
Agency Listings
cULus 60950; TUV EN60950
Safety Timer Codes
(*from pg. 1)
5 = 1.5 hours
6 = 3.0 hours
7 = 6.0 hours
8 = 9.0 hours
Connector
Please specify the Safety Timer Code in your order.
Input Configuration
Pinout Code
Description
IEC320
w/ground
C14
(F)
Battery (+): 1, Thermister: 2, Battery (-): 3
3-pin overmolded Molex connector
Housing 26-03-4041
Terminals 08-50-0187
0.045 square pin on 0.156 centers.
(Ref: Molex Seroes 2220, 5273, 5274)
Suggested Mating
Configuration: In Case IEC320 with ground
Other Connectors are available by special order
A U LT I N C O R P O R AT E D
7105 Northland Terrace
|
Minneapolis, Minnesota 55428
|
USATEL (1) 763-592-1900
FAX (1) 763-592-1911
|
E-MAIL info@aultinc.com
|
WEB www.aultinc.com
© Copyright 2002 Ault Inc.