COLD START 30A(twidth=520 s measured at 50% Ipeak) at 115VAC
μ
COLD START 60A(twidth=520 s measured at 50% Ipeak) at 230VAC
μ
MAX. NO. of PSUs on 16A
4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
CIRCUIT BREAKER
LEAKAGE CURRENT
OVER CURRENT
PROTECTION
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
<0.125mA / 120VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
15 ~ 17V
17.5 ~ 21V 23 ~ 27V
28 ~ 34V
34 ~ 40V
41 ~ 46V
46 ~ 54V
54 ~ 60V
59 ~ 66V
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover
-40 ~ +70
℃
(Refer to "Derating Curve")
20 ~ 95% RH non-condensing
±
0.03%/
℃
(0 ~ 50
℃
)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750 listed, CSA C22.2 No. 250.13-12; IP67(for power body) approved
I/P-O/P:3.75KVAC
Compliance to FCC Part15
294.3K hrs min.
191*63*37.5mm
1.15Kg; 12pcs/13Kg/0.89CUFT
MIL-HDBK-217F (25
℃
)
<0.25mA / 240VAC
ENVIRONMENT STORAGE TEMP., HUMIDITY
-40 ~ +80
℃
, 10 ~ 95% RH
ISOLATION RESISTANCE
I/P-O/P:100M Ohms / 500VDC / 25
℃
/ 70% RH
EMC EMISSION
MTBF
OTHERS DIMENSION
PACKING
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
℃
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel
capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:OWA-120U-SPEC 2017-08-04
120W Single Output Moistureproof Adaptor
Block Diagram
O WA - 1 2 0 U
series
PFC fosc : 50~120KHz
PWM fosc : 60~130KHz
RECTIFIERS
&
FILTER
O.L.P.
O.T.P.
O.L.P.
PWM & PFC
CONTROL
DETECTION
CIRCUIT
O.V.P.
I/P
EMI FILTER
&
RECTIFIERS
PFC
CIRCUIT
POWER
SWITCHING
+V
-V
Derating Curve
Static Characteristics
100
100
90
80
230VAC
Input only
12V,15V only
80
70
60
LOAD (%)
LOAD (%)
-25
0
15
30
40 45 50
60
70 (HORIZONTAL)
50
40
60
50
40
20
-40
90
100
125
135
145
155 165
175
180
200
230
264
AMBIENT TEMPERATURE (
℃
)
INPUT VOLTAGE (V) 60Hz
Power Factor Characteristic
Constant Current Mode
1 .0 0
0 .9 5
0 .9 0
0 .8 5
0 .8 0
0 .7 5
0 .7 0
0 .6 5
0 .6 0
0 .5 5
0 .5 0
0 .4 5
0 .4 0
0 .3 5
0 .3 0
10%
20%
30%
40%
50%
60%
70%
80%
90% 100%
(120W)
LOAD
PF
230V
115V
File Name:OWA-120U-SPEC 2017-08-04
120W Single Output Moistureproof Adaptor
EFFICIENCY vs LOAD (48V Model)
O WA - 1 2 0 U
series
OWA-120U series possess superior working efficiency that up to 90.5% can be reached in field applications.
92
91
90
89
88
87
86
85
84
83
82
81
80
79
78
10%
20%
30%
40%
50%
60%
70%
80%
90% 100%
EFFICIENCY (%)
230V
115V
LOAD
DRIVING METHODS OF LED MODULE
There are two major kinds of LED drive method, "direct drive" and "with LED driver".
A typical LED power supply may either work in "constant voltage mode (CV)" or "constant current mode (CC)" to drive the LEDs.
Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode (with LED driver, at area (A) and CC mode (direct drive, at area (B).
100
(A) Constant
Voltage area
(B)
Constant
Current area
In the constant current region, the highest voltage at the output of the driver
depends on the configuration of the end systems.
Should there be any compatibility issues, please contact MEAN WELL.
60
(min.)
(C)
Hiccup
Protection
50
100
Io (%)
Vo(%)
Typical LED power supply I-V curve
File Name:OWA-120U-SPEC 2017-08-04
120W Single Output Moistureproof Adaptor
Mechanical Specification
O WA - 1 2 0 U
Case No. PWM-120
series
Unit:mm
1500
±
20
500
±
10
191
5
300
±
20
5
ψ
4.
T case
tc
63
5
95.5
50
±
3
23
14
SVT 18AWG
×
2C
31.5
5
2-
UL2464 18AWG
×
4C
5
tc
: Max. Case Temperature
Input Plug Ty
pe
All models : NEMA 1-15p male plug
3
Output Plug Assignment
All models : power DIN 4 pins with lock type,
KYCON KPPX-4P, or equivalent
PIN NO. OUTPUT
2
1
3
4
1,4
2,3
+V
-V
Recommend Mounting Direction
Installation Manual
Please refer to : http://www.meanwell.com/manual.html