REVISION BX
DO NOT
SCALE FROM
THIS PRINT
NOTES:
1.
C
REPRESENTS A CRITICAL DIMENSION.
No OF POSITIONS
2. PARTS MAY BE CUT TO POSITION.
-02 THRU -50
3. MAXIMUM CUT FLASH: .010[0.25] ON TAIL SIDE, ALL OTHER AREAS
(PER ROW)
AT .015[0.38]. LOOSE CUT FLASH MUST BE REMOVED.
4. MINIMUM PUSHOUT FORCE: 1.0 LB.
LEAD STYLE
5. TERMINALS TO BE SHEARED TO MEET DIMENSION SPECIFICATION.
-01: .120 [3.05]
6. LAYER PACKAGE 2 - 4 POSITIONS AND TUBE 5 - 50 POSITIONS.
-02: .075 [1.91]
7. MAXIMUM BURR ALLOWANCE: .003[0.08].
-03: .065 [1.65]
8. DUE TO THE HIGH AMOUNT OF INSERTION FORCE NEEDED, THE -EC OPTION
-04: .150 [3.81]
IS NOT COMPATIBLE WITH AUTO PLACEMENT. SAMTEC RECOMMENDS
MANUAL PLACEMENT FOR ALL ASSEMBLIES WITH THE -EC OPTION.
9. MAXIMUM HEIGHT VARIATION BETWEEN ROWS: .005[0.13].
PLATING SPECIFICATION
10. VOIDS MAY OR MAY NOT BE PRESENT ON POSITIONS 5 THROUGH 8
AND CAN BE MIXED WITHIN AN ORDER.
-G:10µ" GOLD IN CONTACT AREA,
3µ" GOLD ON TAIL
-F: 3µ" FLASH SELECTIVE GOLD IN CONTACT
AREA, MATTE TIN ON TAIL
(No OF POS x .0500[1.270])
+.005
[
+0.13
]
-.010 -0.25
-L: 10µ" LIGHT SELECTIVE GOLD IN CONTACT
AREA, MATTE TIN ON TAIL
(No OF POS x .0500[1.270]) - .0500[1.270]
-S: 30µ" SELECTIVE GOLD IN CONTACT AREA,
MATTE TIN ON TAIL
-H: 30µ" HEAVY GOLD IN CONTACT AREA,
50
02
3µ" GOLD ON TAIL
-FM: 3µ" FLASH SELECTIVE GOLD IN CONTACT
AREA, MATTE TIN ON TAIL
.135 3.43
-LM: 10µ" LIGHT SELECTIVE GOLD IN CONTACT
AREA, MATTE TIN TAIL
REF
-SM: 30µ" SELECTIVE GOLD IN CONTACT AREA,
MATTE TIN ON TAIL
-LTL: 10µ" LIGHT GOLD IN CONACT AREA,
49
TIN/LEAD (90%/10 +/-5%) ON TAIL
01
FTSH-1XX-XX-XXX-D-XXX-XX
OPTIONS
-ES: END SHROUDS (SEE FIG 2, SHT 2)
(MOLDED 5 POS MIN; -02 & -03 LEAD STYLE ONLY)
(MUST USE FTSH-XX-ES-XX-X)
(SNAP SHROUDS 9 POS MIN; -02 & -03 LEAD STYLE ONLY)
(MUST USE FTSH-50-D)
-EJ: EJECTOR SHROUDS: (SEE FIG 3, SHT 2)
(10 POS MIN; -01 LEAD STYLE ONLY)
(MUST USE FTSH-50-D)
-EC: LOCKING CLIP (SEE FIG 4, SHT 2; SEE NOTE 8)
(9 POS MIN; -02 & -03 LEAD STYLES ONLY)
(MUST USE FTSH-50-D)
-EP: GUIDE POST (SEE FIG 5, SHT 2)
(9 POS MIN; -02 & -03 LEAD STYLES ONLY)
(USE ONLY WHEN MATING WITH CLP)
(MUST USE FTSH-50-D)
-EL: BOARD LOCKS (SEE FIG 6, SHT 2)
(9 POS MIN; -02 & -03 LEAD STYLES ONLY)
(USE ONLY WHEN MATING WITH CLP)
(MUST USE FTSH-50-D)
-K: KEYING OPTION FOR MATING WITH FFSD
(05 THRU 25 ONLY)
(POSITION 13, 17, 20 & 25 AVAILABLE WITH -EJ OPTION)
(LEAD STYLE -01 ONLY, SEE FIG 7, SHT 3)
(MUST USE FTSH-XX-CN-XX)
-LC: LOCKING CLIP: (SEE FIG 8, SHT 3)
(5 POS MIN, ONLY AVAILABLE IN -01 LEAD STYLE)
(IN COMBINATION WITH -K, USE FTSH-XX-CN-XX,
10 POSITION MINIMUM, ONLY AVAILABLE IN
-01 LEAD STYLE)
(MUST USE FTSH-50-D)
(SINGLE MATING CYCLE ONLY)
(MUST BE MATED TO SAMTEC FFSD SERIES)
FTSH-50-D
ROW SPECIFICATION
-D: DOUBLE ROW
POLARIZING OPTION
XXX INDICATES POSITION TO BE OMITTED
(NOT AVAILABLE WITH EX OPTIONS)
(ONLY AVAILABLE WITH -F, -FM, -L, -LM PLATING OPTIONS)
.0160 0.406 SQ
REF (TYP)
2 MAX SWAY
(EITHER DIRECTION)
C
.050 1.27
2 MAX SWAY
(EITHER DIRECTION)
.070 1.78 REF
(CONTACT AREA)
"A"
(SEE TABLE 1)
(SEE NOTE 9)
C
T-1S15-XX-XXX
SEE TABLE 1
"A"
(SEE TABLE 1)
(SEE NOTE 9)
"C" REF
(SEE TABLE 1)
.099 2.51
"B"
(SEE TABLE 2)
(SEE NOTES 5 & 7)
SEE NOTE 3
(2 PLCS)
FIG 1
2 MAX SWAY
(EITHER DIRECTION)
IN-PROCESS
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
DECIMALS
*
PROPRIETARY NOTE
*
THIS DOCUMENT CONTAINS CONFIDENTIAL AND
PROPRIETARY INFORMATION AND ALL DESIGN,
MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS
AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC,
INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE
OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR
REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY
OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS
WRITTEN CONSENT OF SAMTEC, INC.
.XX: .01 [.3]
1
.XXX: .005 [.13]
.XXXX: .0010 [.025]
ANGLES
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733
FAX: 812-948-5047
e-Mail info@SAMTEC.com
code 55322
DESCRIPTION:
DWG. NO.
MATERIAL:
DO NOT SCALE DRAWING
SHEET SCALE: 5:1
INSULATOR: LCD UL 94-V0
TERMINAL: PHOSPHOR BRONZE
.050 x .050 CL THROUGH HOLE TERMINAL STRIP
FTSH-1XX-XX-XXX-D-XXX-XX
02/27/1996
SHEET
1
OF
3
F:\DWG\MISC\MKTG\FTSH-1XX-XX-XXX-D-XXX-XX-MKT.SLDDRW
BY:
J. FERRY
REVISION BX
02
.188 4.78
REF
01
(No OF POS x .050[1.27])+.101[2.57] .008[0.20]
ES-FTSH
.265 6.73 REF
(No OF POS x .050[1.27])+.131[3.32]±.008[0.20]
.280 7.11 REF
.139 3.53 REF
.0699 1.775
LC-05-TM
FTSH-EC
(No OF POS x .050[1.27])+.079[3.30]±.008[0.20]
-EC OPTION
(DIFFERENT AS SHOWN, OTHERWISE SAME AS FIG 2)
(No OF POS x .050[1.27])+.231[5.87]±.008[0.20]
FIG 4
.178 4.51
-ES OPTION
(DIFFERENT AS SHOWN, OTHERWISE SAME AS FIG 1)
(-02 OR -03 LEAD STYLE ONLY)
(9 POS MIN FOR SNAP SHROUDS)
(5 POS MIN FOR MOLDED SHROUDS)
.096 2.44
REF
FIG 2
FTSH-XX-D
.075 1.91 REF
(No OF POS x .050[1.27])+.156[3.96] REF
FTSH-EP
.120 3.05 REF
.032[0.81] REF
CHAMFER
.298 7.56
02
.175 4.45
REF
01
FTSH-49-ES-XX-X
.178 4.51
REF
.099 2.51
REF
-EP OPTION
(DIFFERENT AS SHOWN, OTHERWISE SAME AS FIG 2)
(USE ONLY WHEN MATING WITH CLP)
(No OF POS x .050[1.27])+.257[6.53]
(No OF POS x .050[1.27])+.153[3.89]
.125 3.18
REF
FIG 5
(MOLDED SHROUDS)
FTSH-EL
.293 7.44
REF
.303 7.68
USE SUB-FTSH-EJEHA
(2 REQ'D PER ASSEMBLY
EACH USES 1 EHA-02,
1 FTSH-EJ)
POST SIDE OF CONNECTOR
-EJ OPTION
(DIFFERENT AS SHOWN, OTHERWISE SAME AS FIG 1)
(-01 LEAD STYLE ONLY)
FIG 3
(No OF POS x .050[1.27])+.223[1.26]
-EL OPTION
(DIFFERENT AS SHOWN, OTHERWISE SAME AS FIG 2)
(USE ONLY WHEN MATING WITH CLP)
.222 5.65
REF
*
PROPRIETARY NOTE
*
THIS DOCUMENT CONTAINS CONFIDENTIAL AND
PROPRIETARY INFORMATION AND ALL DESIGN,
MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS
AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC,
FIG 6
.440 11.18
REF
INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE
OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR
REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY
OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS
WRITTEN CONSENT OF SAMTEC, INC.
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733
FAX: 812-948-5047
e-Mail info@SAMTEC.com
code 55322
DESCRIPTION:
DO NOT SCALE DRAWING
.050 x .050 CL THROUGH HOLE TERMINAL STRIP
DWG. NO.
.090 2.29
((No OF POS x .050[1.27]) + .621[15.77])±.010[0.25]
F:\DWG\MISC\MKTG\FTSH-1XX-XX-XXX-D-XXX-XX-MKT.SLDDRW
SHEET SCALE: 2:1
FTSH-1XX-XX-XXX-D-XXX-XX
02/27/1996
SHEET
2
OF
3
BY:
J. FERRY
REVISION BX
((No OF POS x .0500[1.270])
-.003[0.08]±.006[0.15]
.085 2.16
REF
02
.200 5.08
REF
01
C
L
.085 2.16 REF
.200 5.08 REF
.126 3.20 REF
PT-1-24-05-09
FTSH-50-CN-XX
SEE NOTE 10
-K OPTION
(LEAD STYLE -01)
(DIFFERENT AS SHOWN, OTHERWISE SAME AS FIG 1)
(POSITION 13, 17, 20 & 25 AVAILABLE WITH -K & -EJ OPTION)
PT-1-24-01-43
PT-1-24-11-09
FIG 7
LTC-31-01
-01, -02, -03
-04 & -K
-EJ, EJ-K, -LC & -LC-K
.428 10.874
REF
.12 3.1
PT-1-24-01-38
PT-1-24-03-09
PT-1-24-01-55
.270 6.86
REF (TYP)
C
((No OF POS x .050[1.27])
+ .306[7.77])±.008[0.20]
-EC & -EC-K
-EL, -EP, -EL-K & -EP-K
TUBE VIEWS
-ES & -ES-K
FIG 9
-LC OPTION
(LEAD STYLE -01)
(DIFFERENT AS SHOWN, OTHERWISE SAME AS FIG 1)
FIG 8
F:\DWG\MISC\MKTG\FTSH-1XX-XX-XXX-D-XXX-XX-MKT.SLDDRW
*
PROPRIETARY NOTE
*
THIS DOCUMENT CONTAINS CONFIDENTIAL AND
PROPRIETARY INFORMATION AND ALL DESIGN,
MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS
AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC,
INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE
OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR
REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY
OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS
WRITTEN CONSENT OF SAMTEC, INC.
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733
FAX: 812-948-5047
e-Mail info@SAMTEC.com
code 55322
DESCRIPTION:
DWG. NO.
DO NOT SCALE DRAWING
.050 x .050 CL THROUGH HOLE TERMINAL STRIP
SHEET SCALE: 2:1
FTSH-1XX-XX-XXX-D-XXX-XX
02/27/1996
SHEET
3
OF
3
BY:
J. FERRY