Corcom Product Guide
High Performance Compact Power Line Filter
Catalog: 1654001
Issue Date: 06.2011
RK Series
UL Recognized
CSA Certified
VDE Approved
1
RFI Power Line Filters
Specifications
Maximum leakage current each Line to Ground:
@ 120 VAC 60 Hz:
0.16 mA
@250 VAC 50 Hz:
0.26 mA
Hipot rating (one minute):
Line to Ground:
Line to Line:
Rated Voltage (max):
Operating Frequency:
Rated Current:
2250 VDC
1450 VDC
250 VAC
50/60 Hz
3 to 20A
RK Series
• Compact
• Single stage
• Chassis mount
• Significant differential mode performance
• Suitable for industrial machinery
• Low input leakage current makes it suitable for
portable equipment
Ordering Information
10 E RK 1
Input / Output Style
1 – .250 [6.3] spade terminals
RK Series
Leakage current designation
E – Low leakage
(<0.5 mA)
Current Rating
3, 6, 10, 15 or 20A
Operating Ambient Temperature Range
(at rated current Ir):
-10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir
(85-Ta)/45
Electrical Schematic
LINE
LOAD
Available Part Numbers
3ERK1
10ERK1
20ERK1
6ERK1
15ERK1
65
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Corcom Product Guide
High Performance Compact Power Line Filter
(continued)
Catalog: 1654001
Issue Date: 06.2011
RK Series
Case Styles
RK1
(3 & 6A)
A
E
D
Case Dimensions
Part No.
3ERK1
A
B
C
C
6ERK1
10ERK1, 15ERK1,
20ERK1
D
E
B
RK1
(10, 15 & 20A)
A
E
D
C
B
½
½½
66
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Corcom Product Guide
High Performance Compact Power Line Filter
(continued)
Catalog: 1654001
Issue Date: 06.2011
RK Series
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
1
10RK
db
100
90
80
70
60
50
40
30
20
10
3RK
db
100
90
80
70
60
50
40
30
20
10
0
0.01
0.1
1
10
30
Frequency in MHz
6RK
db
100
90
80
70
60
50
40
30
20
10
0
0.01
0.1
1
10
30
Frequency in MHz
15RK
db
100
90
80
70
60
50
40
30
20
10
RFI Power Line Filters
0
0.01
0.1
1
10
30
Frequency in MHz
0
0.01
0.1
1
10
30
Frequency in MHz
20RK
db
100
90
80
70
60
50
40
30
20
10
0
0.01
0.1
1
10
30
Frequency in MHz
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
Minimum Insertion Loss
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
67
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com