= 25°C and V+ = 4 V to 6.5 V, unless otherwise noted.
Table 1.
Parameter
TRANSFER FUNCTION
TEMPERATURE COEFFICIENT
TOTAL ERROR
Initial Error
T
A
= 25°C
Error Overtemperature
T
A
= T
MIN
T
A
= T
MAX
Nonlinearity
T
A
= T
MAX
to T
MIN
OUTPUT CHARACTERISTICS
Nominal Output Voltage
V+ = 5.0 V, T
A
= 0°C
V+ = 5.0 V, T
A
= +100°C
V+ = 5.0 V, T
A
= −40°C
V+ = 5.0 V, T
A
= +85°C
V+ = 5.0 V, T
A
= −50°C
V+ = 5.0 V, T
A
= +150°C
POWER SUPPLY
Operating Voltage
Quiescent Current
TEMPERATURE RANGE
Guaranteed Temperature Range
Operating Temperature Range
PACKAGE
Min
AD22100K
AD22100A
AD22100S
Typ
Max
Min
Typ
Max
Min
Typ
Max
V
OUT
= (V+/5 V) × [1.375 V +(22.5 mV/°C) × T
A
]
(V+/5 V) × 22.5
Unit
V
mV/°C
±0.5
±0.75
±0.75
±2.0
±2.0
±2.0
0.5
±1.0
±2.0
±2.0
±2.0
±3.7
±3.0
0.5
±1.0
±3.0
±3.0
±2.0
±4.0
±4.0
1.0
°C
°C
°C
% FS
1
1.375
3.625
0.475
3.288
0.250
4.750
4.0
5.0
500
6.5
650
+100
+150
TO-92
SOIC
4.0
5.0
500
6.5
650
+85
+150
TO-92
SOIC
4.0
5.0
500
6.5
650
+150
+150
TO-92
SOIC
V
V
V
V
V
V
V
µA
°C
°C
0
−50
−40
−50
−50
−50
1
FS (full scale) is defined as the operating temperature range −50°C to +150°C. The listed maximum specification limit applies to the guaranteed temperature range.
For example, the AD22100K has a nonlinearity of (0.5%) × (200°C) = 1°C over the guaranteed temperature range of 0°C to +100°C.
CHIP SPECIFICATIONS
T
A
= 25°C and V+ = 5.0 V, unless otherwise noted.
Table 2.
Paramater
TRANSFER FUNCTION
TEMPERATURE COEFFICIENT
OUTPUT CHARACTERISTICS
Error
T
A
= 25°C
Nominal Output Voltage
T
A
= 25°C
POWER SUPPLY
Operating Voltage
Quiescent Current
TEMPERATURE RANGE
Guaranteed Temperature Range
Operating Temperature Range
Min
Typ
Max
V
OUT
= (V+/5 V) × [1.375 V +(22.5 mV/°C) × T
A
]
(V+/5 V) × 22.5
Unit
V
mV/°C
±0.5
1.938
4.0
5.0
500
+25
−50
Rev. D | Page 3 of 12
±2.0
°C
V
6.5
650
V
µA
°C
°C
+150
AD22100
ABSOLUTE MAXIMUM RATINGS
Table 3.
Parameter
Supply Voltage
Reversed Continuous Supply Voltage
Operating Temperature
Storage Temperature
Output Short Circuit to V+ or Ground
Lead Temperature Range
(Soldering 10 sec)
Junction Temperature
Rating
10 V
−10 V
–50°C to +150°C
–65°C to +160°C
Indefinite
300°C
150°C
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only and functional operation of the device at these or
any other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on
the human body and test equipment and can discharge without detection. Although this product features
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance