SEU60-201

Description
63W Enclosed Switching Power Supplies
File Size563KB,2 Pages
ManufacturerETC2
Download Datasheet View All

SEU60-201 Overview

63W Enclosed Switching Power Supplies

SEU60 SERIES
63W Enclosed Switching Power Supplies For I.T.E.
Description:
The SEU60 series of compact, open frame constructed, AC/DC
switching mode power supplies provide 63 Watts of continuous output
power . They are ideally suited for use in CRT terminals, disc drive
systems, microprocess or based systems, portable equipments and
many other applications, all models are designed to meet the safety
requirements of UL1950/EN60950 requirements. All units are 100%
burned in and tested.
Features:
Wide Input Voltage 90 to 264 VAC,47 to 63 Hz
Internal EMI filter
Single to Quad Output
Input connector mates with Molex housing 09-50-3051 and
Molex 2878 series crimp terminal
Output connector mates with Molex housing 09-50-3061 (or
09-50-3081) and Molex 2878 series crimp terminal
Output Voltage Available From 3 VDC Thru 50 VDC
Input Surge Current, Over Voltage and Over Load protection
Class I Insulation
Two Years Warranty
Safety Approvals :
ITS
C
Test Conditions
Electrical Characteristics:
Sym.
Vin
Fin
Wo
Vo
Io
Iil
Iih
Irl
Irh
Eff
REG-i
REG-o
OVP
OCP
Ttr
Thold
Ts
Vrn
Ilk
Tc
US
Testing &
Certification
Bauart
gepruft
CB
Max.
Unit
VAC
Hz
W
V
A
A
A
A
A
%
%
%
%
%
mS
mS
S
%
mA
%/
°c
Parameter
Input Voltage
Input Frequency
Output Power Range
Output Voltage Range
Output Current Range
Input Current (Low Line)
Input Current (High Line)
Low Line Inrush Current
High Line Inrush Current
Min.
Typ.
Vin=90 to 264VAC
Efficiency
Vin=230VAC
70
80
Line Regulation
0.5
Load Regulation
3
Over Voltage Protection
112
Over Current Protection
110
Transient Response
Io=Full Load to Half Load, Vin=100VAC
Hold-Up Time
Io=Full Load, Vin=100VAC
18
20
Start Up Time
Io=Full Load, Vin=100VAC
0.3
1
Ripple & Noise (Pe ak to Peak) Full Load, Vin=90VAC
1
Safety Ground Leakage Current Io=Full Load, Vin=240VAC
0.4
Temperature Coefficient
All output
-0.04
Io=Full load,
Io=Full load,
Io=Full load,
Vin=115VAC
Io=Full load,
Vin=230VAC
Io=Full Load,
Io=Full Load
Vin=230VAC
Vin=115VAC
Vin=230 VAC
25
°c
, Cool start,
25
°c
, Cool start,
90
264
47
63
0
63
See rating chart
See rating chart
1.6
1.0
12
26
15
30
88
1
6
132
150
4
2
2
0.45
0.04
Environmental :
Sym.
Toper
Tstg
Hr
Pd
Parameter
Test Conditions
Min.
0
-40
5
Typ.
Max.
70
85
95
Unit
°c
°c
Operating Temperature
Storage Temperature
Relative Humidity
Derate linearly from 100% load at 40°c to 50% load at 70°c
%
Safety Specifications:
Sym.
Vps
Parameter
Test Conditions
Primary to secondary
Primary to ground
Test Voltage = 500VDC
Vin=220VAC
Vin=110VAC
Min.
4242
2121
50
B
B
Typ. Max.
Unit
VDC
VDC
Dielectric Withstanding Voltage
for Primary to secondary
Dielectric Withstanding Voltage
Vpg
for Primary to ground
Ri Isolation Resistance
CISPR EMI requirements for CISPR-22
FCC EMI requirements for FCC PART-15
MW
CLASS
CLASS

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号